Skip to main content
Log in

Precise Determination of Cr and Co in Certified Reference Material of Silicon Nitride by Neutron Activation Analysis Using Internal Standardization

  • Published:
Analytical Sciences Aims and scope Submit manuscript

Abstract

Neutron activation analysis with an internal standard correction was applied to the determination of Cr and Co in a ceramics certified reference material (NMIJ CRM 8004-a silicon nitride powder). Cesium was used as an internal standard to compensate for any inhomogeneity of the neutron flux through an irradiation capsule and to improve the repeatability of gamma-ray measurements. It was found that the linearity of the calibration curves of Cr and Co was improved by using an internal standard. The analytical results of Cr and Co in NMIJ CRM 8004-a were in good agreement with those obtained by ICP-OES, ICP-sector field mass spectrometry (ICP-SFMS), and isotope dilution/ICP-SFMS for Cr. The relative expanded uncertainties (k = 2) were 1.9% for Cr and 1.5% for Co. The uncertainties were comparable to those of atomic spectrometric methods.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. M. J. T. Milton and T. J. Quinn, Metrologia, 2001, 38, 289.

    Article  CAS  Google Scholar 

  2. R. R. Greenberg, J. Radioanal. Nucl. Chem., 2008, 278, 231.

    Article  CAS  Google Scholar 

  3. M. Ebihara and T. Miura, Geochim. Cosmochim. Acta, 1996, 60, 5133.

    Article  CAS  Google Scholar 

  4. R. R. Greenberg, R. M. Lindstrom, and D. S. Simons, J. Radioanal. Nucl. Chem., 2000, 245, 57.

    Article  CAS  Google Scholar 

  5. A. R. Byrne, Fresenius J. Anal. Chem., 1993, 345, 144.

    Article  CAS  Google Scholar 

  6. J. Kucera, P. Bode, and V. Stepanek, in “Quantifying Uncertainty in Nuclear Analytical Measurements”, IAEA TECDOC 1401, 2004, Vienna, Austria, 77 – 101.

  7. R. M. Lindstrom and R. R. Greenberg, J. Nucl. Radiochem. Sci., 2001, 2, R1.

    Article  Google Scholar 

  8. G. Leliaert, J. Hoste, and Z. Eechhaut, Nature, 1958, 182, 600.

    Article  CAS  Google Scholar 

  9. M. Yagi and K. Masumoto, J. Radioanal. Nucl. Chem., Articles, 1984, 83/2, 319.

  10. C. Yonezawa, S. Ichimura, T. Kurosawa, and H. Matsue, JAERI-Tech 98-046, 1998, Tokai, Japan.

  11. C. Yonezawa, H. Imai, T. Hongo, M. Hoshi, E. Tachikawa, M. Kabuto, and T. Suzuki, Bunseki Kagaku, 1992, 41, 581.

    Article  CAS  Google Scholar 

  12. Y. Uwamino, A. Tsuge, H. Morikawa, A. Hioki, and N. Nonose, “Technical Report of Development of Silicon Nitride Powder Direct Nitrization II Certified Reference Material NMIJ CRM 8004-a”, 2007, NMIJ-AIST, Tsukuba, Japan.

  13. B. Fazekas, G. L. Molnar, T. Belgya, L. Dabolczi, and A. Simonnits, J. Radioanal. Nucl. Chem., 1997, 215, 271.

    Article  CAS  Google Scholar 

  14. M. Blaauw, “The k0 -Consisitent IRI Gamma-Ray Catalogue for INAA”, 1996, Interfacultair Reactor Insituut van de Technische Universiteit Delft, the Netherlands.

  15. L. A. Currie and G. Svehla, Pure Appl. Chem., 1995, 66, 595.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Tsutomu Miura.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Miura, T., Matsue, H., Kuroiwa, T. et al. Precise Determination of Cr and Co in Certified Reference Material of Silicon Nitride by Neutron Activation Analysis Using Internal Standardization. ANAL. SCI. 25, 881–885 (2009). https://doi.org/10.2116/analsci.25.881

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.2116/analsci.25.881

Navigation