Skip to main content
Log in

Blank Membranes versus Ionophore-based Membranes for the Selective Determination of H+

  • Published:
Analytical Sciences Aims and scope Submit manuscript

Abstract

A pH electrode for the selective determination of H+ was introduced. Both phosphorated calix[6]arene and a N,N′-bisethoxycarbonyl-1, 10-diaza-4, 7, 13, 16-tetraoxacyclo-octadecane (DZCE) were used as new H+-ionophores. The calibration graphs of the obtained electrodes exhibits satisfactory Nernstian slopes. The electrodes were compared to blank membranes (without any ionophoric substances) for the first time. Selectivity coefficients of the studied electrodes towards several inorganic cations were calculated. The relative selectivity coefficient (RSC) was applied for evaluating the selectivity properties of H+-electrode using a mathematical equation. The electrodes were applied for the determination of different inorganic and organic acids.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. A. H. J. Maas, H. F. Weisberg, R. W. Burnett, O. Muller-Plathe, P. D. Wimberley, W. G. Zijlstra, R. A. Durst, and O. Siggard-Andersen, J. Clin. Chem. Clin. Biochem., 1987, 25, 281.

    CAS  PubMed  Google Scholar 

  2. O. Siggard-Andersen, R. A. Durst, and A. H. J. Maas, J. Clin. Chem. Clin. Biochem., 1987, 25, 369.

    Google Scholar 

  3. Y.-H. Liao and J.-C. Chou, Sens. Actuators, B, 2008, 128, 603.

    Article  CAS  Google Scholar 

  4. N. Zine, J. Bausells, F. Teixidor, C. Viñas, C. Masalles, J. Samitier, and A. Errachid, Mater. Sci. Eng. C, 2006, 26, 399.

    Article  CAS  Google Scholar 

  5. X.-J. Liu, B. Peng, F. Liu, and Y. Qin, Sens. Actuators, B, 2007, 125, 656.

    Article  CAS  Google Scholar 

  6. A. Demirel, A. Doan, E. Canel, S. Memon, M. Yilmaz, and E. Kili, Talanta, 2004, 62, 123.

    Article  CAS  PubMed  Google Scholar 

  7. W.-S. Han, M.-Y. Park, K.-C. Chung, D.-H. Cho, and T.-K. Hong, Talanta, 2001, 54, 153.

    Article  CAS  PubMed  Google Scholar 

  8. D.-H. Cho, K.-C. Chung, S.-S. Jeong, and M.-Y. Park, Talanta, 2000, 51, 761.

    Article  CAS  PubMed  Google Scholar 

  9. D.-H. Cho, K.-C. Chung, and M.-Y. Park, Talanta, 1998, 47, 815.

    Article  CAS  PubMed  Google Scholar 

  10. P. Schulthess, Y. Shijo, H. V. Pham, E. Pretsch, D. Ammann, and W. Simon, Anal. Chim. Acta, 1981, 131, 111.

    Article  CAS  Google Scholar 

  11. R. Koncki, A. Chudzik, and I. Walcerz, J. Pharm. Biomed. Anal., 1999, 21, 5157.

    Article  Google Scholar 

  12. G. Horvai and E. Pungor, Anal. Chim. Acta, 1991, 243, 55.

    Article  CAS  Google Scholar 

  13. V. M. Lutov and K. N. Mikhelson, Sens. Actuators, B, 1994, 19, 400.

    Article  CAS  Google Scholar 

  14. K. Komura, M. Yoshinaga, K. Funaki, Y. Shibutani, K. Yakabe, T. Shono, M. Kasai, H. Mizufune, and M. Tanaka, Anal. Sci., 1996, 12, 67.

    Article  Google Scholar 

  15. V. P. Y. Gadzekpo, G. J. Moody, J. D. R. Thomas, and G. D. Christian, Ion-Selective Rev., 1986, 8, 173.

    CAS  Google Scholar 

  16. M. M. Zareh, Anal. Sci., 2008, 24, 889.

    Article  CAS  PubMed  Google Scholar 

  17. M. M. Zareh and E. Malinowska, J. AOAC Int., 2007, 90, 147.

    Article  CAS  PubMed  Google Scholar 

  18. K. Tohda, S. Yoshiyagawa, and Y. Umezawa, J. Mol. Struct., 1997, 408/409, 155.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Mohsen M. Zareh.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Zareh, M.M. Blank Membranes versus Ionophore-based Membranes for the Selective Determination of H+. ANAL. SCI. 25, 1131–1135 (2009). https://doi.org/10.2116/analsci.25.1131

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.2116/analsci.25.1131

Navigation