Abstract
A high-performance liquid chromatographic method was developed for the analysis of capsaicinoid compounds, the pungent principles of capsicum fruits. A sequential simplex method was applied to optimize the chromatographic response function used to assess the quality of separation by varying the chromatographic parameters. The separation was achieved in 11 min using a C-8 column of 15-cm length and 4.6 mm diameter using a UV detector. A flow rate of 1.15 ml min–1 at a column temperature of 43.5°C using 63.7% methanol in water gave the most efficient separation. The method was found to be suitable for the determination of the major capsaicinoid compounds in the capsicum samples.
Similar content being viewed by others
References
K. Lee, T. Suzuki, M. Kobashi, K. Hasegawa, and K. Iwai, J. Chromatogr., 1976, 123, 119.
K. Iwai, T. Suzuki, and H. Fujiwake, J. Chromatogr., 1979, 172, 303.
M. W. Law, J. Assoc. Off. Anal. Chem., 1983, 63, 1304.
A. Szallasi and P. M. Blumberg, Pain, 1996, 68, 195.
V. Govindarajan, S. Narasimhan, and S. Dhanaraj, J. Food Sci. Technol., 1977, 14, 28.
Y. J. Surh and S. S. Lee, Life Sci., 1995, 56, 1845.
Y. J. Surh, S. H. Ahn, K. C. Kim, J. B. Park, Y. W. Sohn, and S. S. Lee, Life Sci., 1995, 56, 305.
A. S. L. Tirimanna, Analyst, 1972, 97, 372.
A. Trejo-Gonzalez and C. Wild-Altamirano, J. Food Sci., 1973, 38, 342.
K. L. Bajaj, J. Assoc. Off. Anal. Chem., 1980, 63, 1314.
T. Anan, H. Ito, H. Matsunaga, and S. Monma, Caps. Eggplant. Newslett., 1996, 15, 51.
J. J. DiCecco, J. Assoc. Off. Anal. Chem., 1976, 59, 1.
B. V. Thomas, A. A. Schreiber, and C. P. Weisskopf, J. Agric. Food Chem., 1998, 46, 2655.
J. Jurenitsch and R. Leinmuller, J. Chromatogr., 1980, 189, 389.
W. S. Hawer, J. Ha, J. Hwang, and Y. Nam, Food Chem., 1994, 49, 99.
A. M. Krajewska and J. Powers, J. Assoc. Off. Anal. Chem., 1987, 70, 926.
A. Laskaridou-Monnerville, J. Chromatogr. A, 1999, 838, 293.
J. E. Woodbury, J. Assoc. Off. Anal. Chem., 1980, 63, 556.
P. G. Hoffman, M. C. Lego, and W. G. Galetto, J. Agric. Food Chem., 1983, 31, 1326.
K. M. Weaver, R. G. Luker, and M. E. Neale, J. Chromatogr., 1984, 301, 288.
T. H. Cooper, J. A. Guzinski, and C. Fisher, J. Agric. Food Chem., 1991, 39, 2253.
T. S. Johnson, G. A. Ravishankar, and L. V. Venkataraman, J. Agric. Food Chem., 1992, 40, 2461.
M. D. Collins, L. M. Wasmund, and P. W. Bosland, Hort. Science., 1995, 30, 137.
M. Parish, J. Assoc. Off. Anal. Chem., 1996, 79, 738.
J. Lu and M. Cwik, J. Chromatogr. B, 1997, 701, 135.
C. A. Reilly, D. J. Crouch, G. S. Yost, and A. A. Fatah, J. Chromatogr. A, 1984, 316, 69.
J. C. Berridge and E. G. Morrissey, J. Chromatogr., 1984, 316, 69.
J. C. Berridge, Analyst, 1984, 109, 291.
F. H. Walters, L. K. Parker, Jr., S. L. Morgan, and S. N. Deming, “Sequential Simplex Optimization: A Technique for Improving Quality and Productivity in Research, Development and Manufacturing”, 1991, CRC Press, Boca Raton.
S. M Sultan and A. H. El-Mubararak, Talanta, 1996, 43, 569.
J. C. Miller and J. N. Miller, “Statistics for Analytical Chemistry”, 1993, Ellis Horwood, New York.
J. N. Miller, Analyst, 1991, 116, 3.
V. K. Attuquayefio and K. A. Buckle, J. Agric. Food Chem., 1987, 35, 777.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Karnka, R., Rayanakorn, M., Watanesk, S. et al. Optimization of High-Performance Liquid Chromatographic Parameters for the Determination of Capsaicinoid Compounds Using the Simplex Method. ANAL. SCI. 18, 661–665 (2002). https://doi.org/10.2116/analsci.18.661
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.2116/analsci.18.661