Abstract
A flow injection (FIA) determination of hydrogen peroxide (H2O2) was developed by using chemiluminescence (CL) reaction of bis(2,4,6-trichlorophenyl)oxalate (TCPO) in an oil/water (O/W) emulsion system composed of ethyl acetate, non-ionic surfactant polyoxyethylene(20) sorbitane monolaurate (Tween 20) and water. The intensity of the light emitted from the CL reaction is proportional to the concentration of H2O2. A linear calibration graph was obtained over the H2O2 concentration range 1×10−6 - 1×10−3 mol dm−3. The relative standard deviations of 3.4 and 3.6% were obtained for five determinations of 1×10−5 and 1×10−6 mol dm−3 of H2O2, respectively. The present method was applied to the determination of L-glutamic acid in culture medium, which was based on the detection of H2O2 produced from glutamic acid in the immobilized glutamate oxidase reactor in the flow system.
Similar content being viewed by others
References
C. Matsubara, N. Kawamoto and K. Takamura, Analyst [London], 117, 1781 (1992).
D. Price, P. J. Worsfold and R. F. C. Mantoura, Anal. Chim. Acta, 298, 121 (1994).
C. Matsubara, J. Flow Injection Anal., 12, 23 (1995).
N. Kiba, F. Ueda, M. Furusawa and T. Yamane, Anal. Chim. Acta, 269, 187 (1992).
K. Yagiuda, A. Herami, K. Sakamura, S. Ito, Y. Asano, K. Hayashi and I. Karube, Denki Kagaku, 63, 114 (1995).
T. Segawa, T. Kamidate and H. Watanabe, Anal. Sci., 6, 763 (1990).
M. Akiba, S. Motomizu and K. Toei, Bunseki Kagaku, 36, 561 (1987).
K. Toei, T. Tamaru and M. Zenki, Anal. Sci., 6, 149 (1990).
K. S. Johnson, C. M. Sakamoto-Arnold, S. W. Willason and C. L. Beehler, Anal. Chim. Acta, 201, 83 (1987).
M. A. Pesce and S. H. Bodourian, Clin. Chem., 23, 757 (1977).
K. Tamaoku, Y. Murao, K. Akiura and Y. Ohkura, Anal. Chim. Acta, 136, 121 (1982).
P. Van Zoonen, D. A. Kamminga, C. Gooijer, N. H. Velthorst and R. W. Frei, Anal. Chim. Acta, 174, 151 (1985).
K. Nakashima, N. Hayashida, S. Kawaguchi, S. Akiyama, Y. Tsukamoto and K. Imai, Anal. Sci, 7, 715 (1991).
M. Katayama, H. Takeuchi and H. Taniguchi, Anal. Lett., 24, 1005 (1991).
O. M. Steijger, P. H. M. Rodenburg, H. Lingeman, U. A. Th. Brinkman and J. J. M. Holthuis, Anal. Chim. Acta, 266, 233 (1992).
P. A. Sherman, J. Holzbecher and D. E. Ryan, Anal. Chim. Acta, 97, 21 (1978).
N. Imaizumi, K. Hayakawa, M. Miyazaki and K. Imai., Analyst [London], 114, 161 (1989).
O. M. Steijger, H. M. Van Mastbergen and J. J. M. Holthuis, Anal. Chim. Acta, 217, 229 (1989).
R. B. Thompson and S. E. Shaw McBee, Langmuir, 4, 106 (1988).
M. Masoom and A. Townshend, Anal. Chim. Acta, 166, 111 (1984).
T. Yao, M. Satomura and T. Nakahara, Talanta, 41, 2113 (1994).
C. C. Wei and E. H. White, Tetrahedron Lett, 39, 3559 (1971).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Hasebe, T., Hasegawa, E. & Kawashima, T. Flow Injection Determination of Hydrogen Peroxide by Bis(2,4,6-trichlorophenyl)oxalate Chemiluminescence in O/W Emulsion. ANAL. SCI. 12, 881–885 (1996). https://doi.org/10.2116/analsci.12.881
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.2116/analsci.12.881