Skip to main content
Log in

Cycle performance studies on a new HFC-161/125/143a mixture as an alternative refrigerant to R404A

  • Energy and Power Engineering
  • Published:
Journal of Zhejiang University SCIENCE A Aims and scope Submit manuscript

Abstract

In this paper, a new ternary non-azeotropic mixture of HFC-161/125/143a (0.15/0.45/0.40 in mass fraction), as a promising mixed refrigerant to R404A, is presented. The ozone depletion potential (ODP) of the new refrigerant is zero and its basic thermodynamic properties are similar to those of R404A, but its global warming potential (GWP) is much smaller than those of R507A and R404A. Meanwhile, theoretical calculations show that, under the working condition I (the average evaporation temperature: −23 °C, the average condensing temperature: 43 °C, the superheat temperature: 28 °C, the subcooling temperature: 5 °C), the volumetric refrigerating effect and specific refrigerating effect of the new mixture are 2.33% and 15.48% higher, respectively, than those of R404A. The coefficient of performance (COP) of the new mixture is 5.19% higher than that of R404A and the pressure ratio of the new mixture is 0.82% lower than that of R404A. Equally, under the working condition II (the average evaporation temperature: −40 °C, the average condensing temperature: 35 °C, the superheating temperature: 30 °C, the subcooling temperature: 5 °C), the volumetric refrigerating effect and specific refrigerating effect of the new mixture are 2.24% and 20.58% higher, respectively, than those of R404A. The COP of the new mixture is 4.60% higher than that of R404A and the pressure ratio of the new mixture is similar to that of R404A. The performances of the new mixture and R404A are compared in a vapor compressor refrigeration apparatus originally designed for R404A under several working conditions (condensing temperatures: 35–45 °C, evaporation temperatures: −40–−20 °C). Experimental results show that the new mixture can obtain a higher COP, by 6.3% to 12.1%, and a lower pressure ratio, by 1.8% to 6.6%, compared to R404A; although the discharge temperature of the new mixture is slightly higher than that of R404A. The advantages of the new mixture will be further verified in the actual system.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Aprea, C., Mastrullo, R., 1996. Behavior and performances of R502 alternative working fluids in refrigerating plant. International Journal of Refrigeration, 19(4):257–263. [doi:10.1016/0140-7007(96)00012-6]

    Article  Google Scholar 

  • Arora, A., Kaushik, S.C., 2008. Theoretical analysis of a vapour compression refrigeration system with R502, R404A and R507A. International Journal of Refrigeration, 31(6):998–1005. [doi:10.1016/j.ijrefrig.2007.12.015]

    Article  Google Scholar 

  • Calm, J.M., Hourahan, G.C., 2007. Refrigerant data summary. Heat/Piping/Air Conditioning Engineering, 79(1):50–64.

    Google Scholar 

  • Chen, G.M., Guo, Z.K., Guo, X.Z., Xuan, Y.M., 2005. A New Alternative Refrigerant to R22. Chinese Patent, No. 03116856.5.

  • Doring, R., Buchwald, H., Hellmann, J., 1997. Results of experimental and theoretical studies of the azeotropic refrigerant R507. International Journal of Refrigeration, 20(2):78–84. [doi:10.1016/S0140-7007(96)00071-0]

    Article  Google Scholar 

  • Granryd, E., 2001. Hydrocarbons as refrigerants—an overview. International Journal of Refrigeration, 24(1):15–24. [doi:10.1016/S0140-7007(00)00065-7]

    Article  Google Scholar 

  • Guo, Z.K., Chen, G.M., Xuan, Y.M., Guo, X.Z., 2005. A New Alternative Refrigerant to R502. Chinese Patent, No. 200310108660.3.

  • Han, X.H., Wang, Q., Zhu, Z.W., Chen, G.M., 2007. Cycle performance study on R32/R125/R161 as an alternative refrigerant to R407C. Applied Thermal Engineering, 27(14–15):2559–2565. [doi:10.1016/j.applthermaleng.2007.01.034]

    Article  Google Scholar 

  • Han, X.H., Qiu, Y., Li, P., Xu, Y.J., Wang, Q., Chen, G.M., 2012. Cycle performance studies on HFC-161 in a small-scale refrigeration system as an alternative refrigerant to HFC-410A. Energy and Buildings, 44:33–38. [doi:10.1016/j.enbuild. 2011.10.004]

    Article  Google Scholar 

  • Jiang, Z., 1997. Development of alternative refrigerant to HCFC22. Organo-Fluorine Industry, (3):8–10.

    Google Scholar 

  • Llopis, R., Torrella, E., Cabello, R., Sánchez, D., 2010. Performance evaluation of R404A and R507A refrigerant mixtures in an experimental double-stage vapour compression plant. Applied Energy, 87(5):1546–1553. [doi:10.1016/j.apenergy.2009.10.020]

    Article  Google Scholar 

  • McLinden, M., Klein, S., Lemmon, E., Peskin, A., 2007. NIST Thermodynamic and Transport Properties of Refrigerants and Refrigerant Mixtures Database (REFPROP), Ver 8.0. National Institute of Standards and Technology, Gaithersburg, MD.

    Google Scholar 

  • Riffat, S.B., Afonso, C.F., Afonso, F., Reay, C.A., 1997. Natural refrigerants for refrigeration and air-conditioning systems. Applied Thermal Engineering, 17(1):33–42. [doi:10.1016/1359-4311(96)00030-0]

    Article  Google Scholar 

  • Swinney, J., Jones, W.E., Wilson, J.A., 1998. The impact of mixed non-azeotropic working fluids on refrigeration system performance. International Journal of Refrigeration, 21(8):607–616. [doi:10.1016/S0140-7007(98) 00039-5]

    Article  Google Scholar 

  • Wang, Q., Meng, L.J., Zhu, Z.W., Chen, G.M., 2009. Experimental study on HFC-161 mixture as an alternative refrigerant to HCFC-22. Journal of Engineering Thermophysics, 30(2):202–204.

    Google Scholar 

  • Wu, Y.Z., 2004. Small Refrigeration Equipment Design Guidelines. China Machine Press, Beijing, p.185-189.

    Google Scholar 

  • Xuan, Y.M., Chen, G.M., 2005. Experimental study on HFC-161 mixture as an alternative refrigerant to R502. International Journal of Refrigeration, 28(3):436–441. [doi:10.1016/j.ijrefrig.2004.04.003]

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Qin Wang.

Additional information

Project supported by the Nation Natural Science Foundation of China (No. 50806063), and the Program for Key Innovative Research Team of Zhejiang Province (No. 2009R50036), China

Rights and permissions

Reprints and permissions

About this article

Cite this article

Han, Xh., Qiu, Y., Xu, Yj. et al. Cycle performance studies on a new HFC-161/125/143a mixture as an alternative refrigerant to R404A. J. Zhejiang Univ. Sci. A 13, 132–139 (2012). https://doi.org/10.1631/jzus.A1100154

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1631/jzus.A1100154

Key words

CLC number

Navigation