Abstract
A simple, sensitive and specific liquid chromatographic method with UV detection (228 nm) was developed for the simultaneous estimation of rosiglitazone and glimepride in human plasma. Rosiglitazone and glimepride were extracted from plasma using liquid–liquid extraction. Separation was achieved with an RP C18 Column using a mixture of phosphate buffer (50 mM) with octane sulfonic acid (10 mM), methanol and acetonitrile as a mobile phase (55:10:35, v/v). pH was adjusted to 7.0. Amlodipine was used as an internal standard (IS). LOD of the method was found to be 20 ng mL−1 for both drugs. Results were linear over the studied range 40.994–2007.556 ng mL−1 for rosiglitazone (r 2 ≥ 0.99) and 41.066–2094.84 ng mL−1 for glimepride( r 2 ≥ 0.99). The method was found to be simple, selective, precise and reproducible for the estimation of both drugs from spiked human plasma.
Similar content being viewed by others
References
Patel J, Miller E, Patwardhan R (1998) Diabetes 47(Suppl 1):A17
Young PW, Buckle DR, Cantello BC, Chapman H, Clapham JC, Coyle PJ, Haigh D, Hindley RM, Holder JC, Kallender H, Latter AJ, Lawrie KWM, Massakowska D, Murphy GJ, Roxbee Cox L, Smith SA (1998) J Pharmacol Exp Ther 284:7
Malerczyk V, Badian M, Korn A, Lehr KH, Waldhansl W (1994) Drug Metab Drug Interact 11:341
Ledercq-Meyer V, Akkan AG, Marchand J, Malaisse WJ (1991) Biochem Pharmacol 42:1634
Ho EN , Yiu KC, Wan TS, Stewart BD, Watkins KL (2004) J Chromatogr., B: Anal Technol Biomed Life Sci 811:65–73
Radhakrishna T, Satyanarayana J, Satyanarayana A (2002) J Pharm Biomed Anal 29:873–880
Muxlow AM, Fowles S, Russell P (2001) J Chromatogr B 752:77–84
Kolte BL, Raut BB, Deo AA, Bagool MA Shinde DB (2003) J Chromatogr B 788:37–44
Kim KA, Park JY (2004) Biomed Chromatogr:613–615
Gomes P, Sippel J, Jablonski A, Steppe M (2004) J Pharm Biomed Anal 36:909–913
Rao NVS, Biju B, Mullangi R (2003) Biomed Chromatogr 17:417–420
Yun-Kyoung S, Jeong-Eun M, Chong-Kook K (2004) J Chromatogr B 810:143–149
Petra K, Klimes J, Dohnal J, Tisovska L (2004) J Pharm Biomed Anal 36:205–209
Khan MA, Sinha S, Vartak S, Bhartiya A, Kumar SJ (2005) Pharm Biomed Anal: 928–943
Lehr KH, Damm P (1990) J Charmatogr 526:497
Khabbaz RL, Daud AR, Zoghbi A (2005) J Liq Chromatogr Relat Technol 28:3255–3263
Salem II, Idrees J, AI Tamimi JI (2004) J Chromatogr B 799:103
Kolte BL, Raut BB, Deo AA, Bagool MA, Shinde DB (2004) J Chromatogr Sci:70–73
Vankatesh P, Harisudhan T, Srinivas NR (2006) Biomed Chromatogr:1043–1048
El Deeb S, Schepers U, Watzig H (2006) J Sep Sci:1571–1577
Sane RT, Menon SN, Gunesh G (2004) Chromatographia:451–453
Bhaskar KL, Bharat BR, Adwait AD, Manoj AB, Devanand BS (2005) J Sep Sci 2076–2079
Guidance for Industry-Bioanalytical Method Validation (2001) US Department Of Health and Human Services, Food and Drug Administration, Center for Drug Evaluation and Research, Center for Veterinary Medicine
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Jingar, J.N., Rajput, S.J., Dasandi, B. et al. Development and Validation of LC-UV for Simultaneous Estimation of Rosiglitazone and Glimepride in Human Plasma. Chroma 67, 951–955 (2008). https://doi.org/10.1365/s10337-008-0633-3
Received:
Revised:
Accepted:
Published:
Issue Date: