Introduction

IUD is still considered as a popular and cost-effective method of reversible contraception worldwide [1, 2]. A displaced or migrated IUD causes serious complications such as vesicouterine fistula, bowel perforation, hydronephrosis, and even renal failure [2,3,4,5,6]. Intravesical translocation of IUD is a rare phenomenon which could be associated with stone formation or bladder perforation [6,7,8]. Surgical removal either through endoscopy or open technique is the best recommended treatment [4,5,6,7,8,9]. We report the case of a reproductive-aged female whose migrated copper IUD was incidentally found through hysterosalpingography (HSG).

Case presentation

A 31-year-old female, gravida 2, para 2 (G2 P2), referred to the gynecologic clinic with a main complaint of secondary infertility during the last twelve months. Written informed consent was obtained from the patient for publication of this case report and any accompanying images. The patient had two previous C-sections. Her menstrual cycles were ovulatory. Spermogram was unremarkable and hormonal assay did not show any abnormality. HSG was performed and revealed a migrated copper IUD with its long tail out of the uterine cavity (Fig. 1). Plain abdominopelvic radiography also indicated a rotated T-shaped IUD in the pelvis (Fig. 2). A transvaginal ultrasound was also performed by a skilled radiologist who reported a copper IUD in the bladder lumen with a small portion of it within the bladder musculature. The patient had taken multiple courses of antibiotics for urinary tract infection (UTI), but her symptoms never disappeared. The patient also underwent cystoscopy for recurrent infection last year, but no pathological finding was detected. Eventually, the patient said that her symptoms were related to the possible adhesions following two previous operations. The patient had a history of IUD insertion following her last C-section about eight years ago. After three years, however, the patient decided to remove it due to recurrent vaginal secretions. Three years later, her IUD was expelled, and another copper IUD was inserted. The patient removed the other copper IUD for becoming pregnant about two years ago. The patient was very confident of its removal, but her recent HSG, interestingly, demonstrated a rotated copper IUD in the pelvic cavity. Physical examination was essentially normal. A baseline complete blood count, urea, and creatinine levels were normal. The patient was candidate for a hysteroscopic cystoscopy. Hysteroscopy was normal except for a small fibrotic defect at the lower segment of the uterus. During cystoscopy, the long tail of the copper IUD was found on the posterolateral border of the bladder far from ureteral offices (Fig. 3). The two short arms adhered to each other were embedded in the mucosal and muscular layer (Fig. 4). No calculus was observed within the bladder cavity. Using glycine as the media, a mono-polar loop entered the bladder. A gentle and brief cautery was applied on the mucosa where the shadow of a short arm of the device was observed. The copper IUD was safely removed through the urethra using a special grasper. There was no major defect in the place of the copper IUD in the bladder. The bleeding points were effectively cauterized (Fig. 5). The patient was discharged the next day with an indwelling catheter. After catheter removal, the patient did not complain of any urinary symptoms.

Fig. 1
figure 1

Hysterosalpingography demonstrating IUD out of uterine cavity

Fig. 2
figure 2

Abdominal X Ray revealing IUD

Fig. 3
figure 3

IUD with its strings in the bladder

Fig. 4
figure 4

Two short arms embedded in the bladder wall

Fig. 5
figure 5

Loop electrode used for releasing the IUD

Discussion

The current study presented the case of a multiparous female with two copper IUD insertions. The first insertion was right after her C-section. Indeed, the first copper IUD, mistakenly thought to have been expelled out of uterus through vagina, had migrated spontaneously from the uterine cavity to the bladder. It could have happened with movement of the device through the cesarean scar defect or after a uterine perforation as a result of improper insertion of the device. The exact mechanism of migration is unknown, but the fact that she had two prior C-sections justifies the first explanation [8,9,10,11].

The patient did not have any complaint of abnormal uterine bleeding except for persistent urinary symptoms wrongly treated with antibiotics. After her normal cystoscopy in another center without abnormal findings, the patient did not follow any further evaluation. The main cause of all symptoms was unexpectedly found using HSG. Among the factors increasing the chance of uterine perforation following IUD insertion such as unusual position of the uterus (acutely anteverted or retroverted), recent pregnancy and insertion by an inexperienced physician or midwife, special attention should be paid to the previous hysterotomy scars which could weaken the uterine wall. It seems that more careful follow-up after IUD insertion is required in women with multiple uterine scars. For this case, when the healthcare provider could not find the device in the cavity, further evaluation such as a simple abdominopelvic X-ray could be done. The possibility of spontaneous expulsion of the IUD should have been made only after thorough inspection of the abdomen and pelvis by different imaging methods. Intravesical migration of the IUD is not a new phenomenon and has been reported in many studies [4, 6,7,8,9,10,11,12,13].

According to potential severe complications of this phenomenon such as bladder or bowel perforation, it is important to confirm the proper place of the device in the uterine cavity as soon as possible [7,8,9]. Therefore, it is recommended to do regular exams to observe and palpate the strings of the IUD along the ultrasound immediately after insertion to affirm the correct insertion [12, 13]. The incidence of bladder perforation following IUD insertion is less than 5 per 1000 cases whose incidence can grow in cases of weakened uterine walls as in the current case [8, 9, 14, 15]. There were two other similar case reports by Niu et al. and Guner et al., in which IUD migration from previous cesarean scar defects happened and resulted in bladder perforation [16, 17].

Therefore, all health care professionals should be aware of the challenging aspect of IUD insertion particularly in women with prior uterine scars. Unlike the two mentioned studies, bladder perforation did not occur in the current case and the IUD was removed successfully through the urethra. The bleeding points at the site of the IUD removal were briefly and superficially cauterized without any complications. This migrated IUD had been misplaced since at least five years ago. Unlike some other studies in which the migrated IUD into the bladder was associated with stone formation [7,8,9], in the current case no stone was found in the bladder. Since the previous cystoscopy was normal in the current case, the migration to the bladder could have occurred recently or just after the first cystoscopy.

Surgical removal of the device is a definite treatment [18]. Both open and endoscopic techniques could be applied for this purpose. Initially minimally invasive approaches are adopted, while open surgical methods are undertaken only if they fail. For the current case, as with other studies [9, 13, 14], hysteroscopy and cystoscopy were sufficient for the management of this complication of the IUD insertion.

Conclusion

IUD insertion seems to be more challenging in women with prior uterine incisions and requires more attention. Cystoscopic removal can be considered as a safe and effective minimally invasive approach to manage a migrated intrauterine device in the bladder.