Background

Due to the enormous demand for conservative and aesthetic restorations [1], fiber-reinforced composites (FRC) have recently been advocated as an alternative to fixed metal framework prostheses. Compared to metal prostheses, FRC restorations are lighter and more esthetic [1]. In addition, the restorations can be effectively adhered to dental tissues and cause less damage to remaining teeth [2]. Although the durability of this type of prosthesis is inferior to metal frameworks, much less time and cost are associated to its placement [2]. FRC’s durability has been reported differently in the related studies, so that the overall durability rate of 75–94.75 percent has been reported after three to 5 years [1, 35].

The use of composite materials in metal-free fixed partial dentures (FPDs) became feasible following the introduction of fiber reinforcement [6]. FRC-based FPDs have good resistance to masticatory forces [6] in addition to their low cost, improved aesthetics, reduced weight, and favorable elastic modulus [7, 8]. Prosthetics manufactured from ceramic material have superior color stability and wear resistance, exhibit marginal adhesion to tooth structure, and have the potential to damage unrestored opposing teeth [9]. FRC materials are currently used not only for crowns and inlays, but also for a variety of clinical esthetic restorations, for example the infrastructure of implant-supported crowns and for FPDs [10]. Although several fiber materials are commercially available, polyethylene and glass fiber reinforcing materials are the most popular [6]. Silanized glass fibers provide good adhesion to the polymer matrix, good aesthetic quality, and improved strength of the resulting composite [8, 11]. The study has have examined the effects of variables such as position, quantity, fiber orientation, and degree of adhesion between the fibers and polymer on the level of reinforcement [12].

FRC materials can adapt to dental contours and are easily manipulated during the bonding process. The materials also possess acceptable strength and clinical durability due to the integration of the fibers with the composite resin and the potential for attachment closer to the incisal edges of teeth, which is useful from a biomechanical perspective [13, 14]. Problems with porcelain-fused-to-metal FPDs include poor aesthetics due to the exposed metal margin and harmful effects on periodontal tissues from the release of metal ions [9]. The increasing application of metal-free FPDs made using ceramic [15] or resin materials [16] is primarily due to advances in high-strength particulate composite resins [17], improved adhesion techniques [18], and the development of high-strength fiber-reinforced composites [19].

The aim of this study was to evaluate the effect of glass-fiber reinforcement on the flexural strength of different resin composites. The null hypotheses tested were (1) that there is no difference in flexural strength among specimens made with different resin composites (bulk-fill, flow, and conventional resin composites), and (2) glass fiber reinforcement has no effect on flexural strength.

Methods

Specimen preparation

Details of the materials used in this study are provided in Table 1. A total of 60 bar-shaped specimens in six groups (n = 10) were prepared in a metal mold (2 × 2 × 20 mm). The samples were prepared using the conventional nanoparticle-filled composite Filtek Z350 XT (batch number 775639; 3M ESPE, St. Paul, MN, USA), Filtek Z350 XT Flow composite (batch number N509855; 3M ESPE), or the bulk-fill X-tra fil composite (batch number 1315355; Voco, Cuxhaven, Germany).

Table 1 Materials used in the study

The materials were placed in the metal mold in a single portion. Sets of 10 specimens of each composite were prepared neat and with pre-impregnated glass fiber reinforcement (batch number 31464; Interlig, Angelus, Londrina, PR, Brazil). The composites were photoactivated with a 40-second exposure (940 mW/cm2) in three areas (extreme right, center, and extreme left) of the metal mold (top surfasse) using an LED lamp (Radii Cal; SDI, Bayswater, VIC, Australia). Following photoactivation, the specimens were stored dry at 37 °C for 24 h. The specimen surfaces were ground using 200-, 400-, and 600-grit SiC abrasive (Carborundum; Saint-Gobain Abrasives, Recife, PE, Brazil) to obtain polished, flat surfaces. The specimen dimensions were measured using a digital caliper (model CD-15C; Mitutoyo, Tokyo, Japan). All procedures were performed by a single operator to ensure standardization.

Flexural strength test

A three-point bending flexural test was performed on each specimen using a universal testing machine (DL2000, EMIC, Equipamentos e Sistemas de Ensaio LTDA, São José dos Pinhais, PR, Brazil). The load was applied perpendicular to the long axis of the specimen at a crosshead speed of 0.5 mm/min until fracture. The flexural strength (FS [MPa]) was calculated using the equation FS = 3 FmaxL/2WH2 [20], in which Fmax is the maximum load in newtons, L is the distance between the support points (8 mm), and W and H are the specimen width and thickness in mm.

Statistical analysis

Mean values and standard deviations (SDs) for flexural strength measurements were calculated using the Minitab 16 program for Windows 8 (Minitab, State College, PA, USA). Normality of the data distributions was investigated using the Kolmogorov–Smirnov normality test. Results were compared using two-way analysis of variance (ANOVA, variables composite and fiber reinforcement) and Tukey’s test at a 5 % significance level (α = 0.05).

Results

Addition of glass fiber increased the flexural strength of all composites (Table 2, p = 0.013). The X-tra fil (102.86 MPa) and Filtek Z350 XT (101.51 MPa) composites without glass fiber had similar flexural performance, however, the X-tra fil composite experienced greater improvement when blended with glass fiber (133.53 MPa). The flexural strength of the Z350 XT Flow composite was also improved by addition of glass fiber, but the performance of this material was lower than the other two composites.

Table 2 Mean flexural strength (MPa) for composites with and without fiber reinforcement with respective standard deviations

Discussion

Flexural strength and modulus of elasticity are the two most important mechanical characteristics in the evaluation of the fiber reinforcement systems [1]. The three-point bending test is a simple method used for comparison of the load bearing capacity of different unidirectional FRC beams [21]. The flexural strength, which is measured in the three-point bending test, determines the behavior of the material under simultaneous tensile and compressive loading [1, 2].

FRC has been used in a variety of dental applications, including denture bases and posts for root canal treatment [22], but it has only recently been used for FPDs [9]. Inlay-retained FPDs reinforced with FRC have a reported survival rate of 72–75 % at 36–63 months after treatment [5]. It has also been noted [5] that the functional survival rate can be improved to 93 % by repair or reinstallation, because the cause of failure in most cases is attributable to dislodgment or partial fracture. From the above discussion, it may be inferred that fiber reinforcement is effective, but a sufficient thickness of veneering composite must be applied to the connector area to prevent fractures [9].

Glass used for the fabrication of such fibers is an amorphous tetrahydrosilicate-based material [1], and the chemical and physical characteristics are distinctly different from organic fibers [1]. Improved adhesion of composites and glass fibers could be due to the sílica contents of the fiber and consequent stronger bonds which in turn lead to an increased flexural strength [23]. Another reason for the high flexural strength of the glass fiber and composites resin combination could be the strongest chemical bond between the glass fiber and the dental polymers [1]. X-tra fil, a bulk fill composite, contains Bis-GMA, UDMA, and TEDMA with 86 wt % filler particules, while Z350 XT contains Bis-GMA, Bis-EMA, UDMA, TEGDMA with 78.5 wt % filler particles and Filtek Z350 XT Flow contains Bis-GMA, TEGDMA, Bis-EMA with 65 wt % filler particles. Moreover, the combination composite with glass fiber presented greater flexural strength than glass fiber alone [1].

One approach to increase the adhesion of fibers to a polymer matrix is resin impregnation of fibers before application [12]. An effective impregnation process enables the resin to come into contact with the surface of every fiber [12]. Wetting the fibers with resin monomer has been a commonly used method. However, although the monomer increases the adhesion of fibers to the matrix, residual monomer may impair other properties [12]. The pre-impregnated fiber used in the present study was developed to overcome this problem [12]. Investigators have confirmed the reinforcing effect of fibers on different polymer types [11, 24, 25]. The increase in flexural strength results from the transfer of stress from the weak polymer matrix to the fibers, which have a high tensile strength [24]. The stronger the adhesion between the fiber and the matrix, the greater the strengthening effect [25]. In composites containing both reinforcing fiber and particulate fillers, the interfacial adhesion and matching of flexural modulus of these two phases plays an important role in increasing the mechanical properties of the material, and further research should be conducted to improve the interfacial bond strength [19].

Reinforcing composites with polyethylene fibers can yield enhanced mechanical properties [26] such as stiffness, strength, toughness, and fatigue resistance [27]. Fibers provide a load-enhancing effect in brittle resin materials by acting as a stress-bearing component and by crack-stopping or crack-deflecting mechanisms [26]. Fixed fiber-reinforced composite bridges offer a suitable alternative to replace missing permanent anterior teeth, particularly in growing children until a fixed prosthesis can be provided at the end of the growth period [28]. Methodologically, limitations such as sample size and aging processes (alternating thermal stresses, mechanical stresses, wear and water storage) should be taken into consideration. Despite the importance of laboratory studies to answer some questions over the short term, the real performance of restorations can only be determined by long-term clinical trials [29].

In specimens in which fiber reinforcement was not used, there were no differences in flexural strength between X-tra fil and Filtek Z350 XT composite. Filtek Z350 XT exhibited high flexural strength despite an inhomogeneous distribution of filler particles [20, 30], while X-tra fil inherently contained a greater proportion of fillers. Filtek Z350 XT Flow demonstrated lower flexural strength, probably due to a lower filler content. However, when other tests were performed (such as the push-out test) the results were not the same [31]. Thus, future studies are needed to demonstrate the efficacy of bulk-fill composites that performed well during flexural testing in this study. The null hypotheses discussed earlier must be rejected because (1) there were differences in flexural strength among specimens prepared from different resin composites, and (2) addition of glass fiber affected the strength of the resulting composite.

Conclusions

Analysis of the flexural strength indicates that glass fiber reinforcement improved the performance of any of the three composites tested. Fiber reinforcement showed highest flexural strength with the bulk-fill composite, while the lowest flexural strength was observed for the flowable composite.