Abstract
Background
Near-infrared spectroscopy (NIRS) provides regional tissue oxygenation (rSO2) even in pulseless states, such as out-of-hospital cardiac arrest (OHCA). Brain rSO2 seems to be important predictor of return of spontaneous circulation (ROSC) during cardiopulmonary resuscitation (CPR). Aim of our study was to explore feasibility for monitoring and detecting changes of skeletal muscle rSO2 during resuscitation.
Methods
Skeletal muscle and brain rSO2 were measured by NIRS (SenSmart Model X-100, Nonin, USA) during CPR in adult patient with OHCA. Start (basal) rSO2, maximal during CPR (maximal) and difference between maximal–minimal rSO2 (delta-rSO2), were recorded. Patients were divided into ROSC and NO-ROSC group.
Results
20 patients [age: 66.0ys (60.5–79.5), 65% male] with OHCA [50% witnessed, 70% BLS, time to ALS 13.5 min (11.0–19.0)] were finally analyzed. ROSC was confirmed in 5 (25%) patients. Basal and maximal skeletal muscle rSO2 were higher in ROSC compared to NO-ROSC group [49.0% (39.7–53.7) vs. 15.0% (12.0–25.2), P = 0.006; 76.0% (52.7–80.5) vs. 34.0% (18.0–49.5), P = 0.005, respectively]. There was non-linear cubic relationship between time of collapse and basal skeletal muscle rSO2 in witnessed OHCA and without BLS (F-ratio = 9.7713, P = 0.0261). There was correlation between maximal skeletal muscle and brain rSO2 (n = 18, rho: 0.578, P = 0.0121).
Conclusions
Recording of skeletal muscle rSO2 during CPR in patients with OHCA is feasible. Basal and maximal skeletal muscle rSO2 were higher in ROSC compared to NO-ROSC group.
Clinical trial registration number ClinicalTrials.gov, NCT04058925, registered on: 16th August 2019. URL of trial registry record: https://www.clinicaltrials.gov/ct2/show/NCT04058925?titles=Tissue+Oxygenation+During+Cardiopulmonary+Resuscitation+as+a+Predictor+of+Return+of+Spontaneous+Circulation&draw=2&rank=1.
Explore related subjects
Find the latest articles, discoveries, and news in related topics.Background
Out of hospital cardiac arrest (OHCA) is a major cause of morbidity and mortality around the world [1]. Despite the progress in medicine, new devices and research, there was no great breakthrough in recent years [2]. There are numerous factors that have influence on the outcome of cardiopulmonary resuscitation (CPR) in OHCA. It is usually impossible to predict weather the resuscitation will be successful or not, especially in early stages of cardiac arrest [3].
Near-infrared spectroscopy (NIRS) is a noninvasive optical technique that uses light in near-infrared spectrum of electromagnetic wave (700–1300 nm) [4, 5]. NIRS can be used to assess tissue oxygenation, oxygen consumption and blood flow in various tissues, including brain and skeletal muscle [6,7,8]. NIRS has an advantage over pulsatile oximetry, because it can be used in situations, where there is no blood flow [9]. With NIRS we measure oxygen saturation in all vessels that are smaller in diameter than 1 mm (arterioles, capillaries, venules) [4, 10]. Most of the signal comes from capillaries, because they represent majority of vessels in the tissue [6].
During cardiac arrest and during CPR the blood flow through the brain is absent or significantly reduced. Brain injury is major cause for neurologic disability after successful resuscitation [4, 7, 10]. With the placement of NIRS probes on the forehead region, regional tissue oxygen saturation (rSO2) in superficial areas of frontal brain lobes is measured. Current data confirms that increase of brain rSO2 is associated with higher probability of return of spontaneous circulation (ROSC) [4, 7, 9,10,11,12]. Different values of basal brain rSO2 or different values of brain rSO2 increase were associated with higher probability of ROSC. Genbrugge et al. reported that absolute increase of rSO2 for 15% or more was associated with ROSC. They also noticed that increase in rSO2 beyond 1 min after initiation of rSO2 measurement was associated with more favorable long-term neurologic outcome [13]. Parnia et al. have shown that all patients with ROSC had mean brain rSO2 of 35% or higher. A rise of brain rSO2 from baseline was associated with ROSC and values remaining below 30% most of the period of CPR predicted that ROSC will not be achieved [12]. Recent meta-analysis has confirmed prognostic value of brain tissue oxygenation [14].
During cardiac arrest there is no blood flow, the consequence is lower oxygen values in all tissues [15, 16]. Skeletal muscles are not part of vital organs and flow through them is decreased in critical states. In critically ill we currently monitor skeletal muscle rSO2 in patients with shock or in patients on different types of circulatory mechanical support [8, 17]. We have previously shown that skeletal muscle rSO2 can predict adequacy of flow (i.e., mixed venous oxygenation) in patients with shock with preserved oxygen extraction; it can also be used to track effects of therapy [8, 18]. Despite new NIRS technologies and design of probes, skeletal muscle rSO2 monitoring remains technically more reliably compared to brain rSO2, because skeletal muscle is covered with a thin layer of skin and subcutis compared to brain, which is hidden in the skull and floating in the cerebrospinal fluid [19]. A short paper already reported an illustrative case series of skeletal muscle rSO2 use in five patients in the emergency department, showing fast response of skeletal muscle rSO2 value to loss or return of pulse [15].
Aim of our study is to test feasibility to monitor skeletal muscle rSO2 during CPR after OHCA and to assess changes of skeletal muscle rSO2 during CPR and after ROSC. In addition, we want to explore the relationship between skeletal muscle and brain rSO2.
Methods
Study design and setting
The single-center, prospective, non-randomized and observational study was conducted at a prehospital area that is covered by the Emergency Unit of Community Health Centre Ljubljana and the Rescue station of University Medical Centre Ljubljana during September 2019 and May 2022. The prehospital area has 1670 km2 and provides emergency services for around 450.000 inhabitants and additionally over 60.000 daily working migrants.
The research protocol received approval by Slovenian Medical Ethics Committee (No. 0120-334/2019/3); patients’ consent was waived because of the observational nature of the study and emergency setting. Study protocol was registered at clinicaltrials.gov (NCT04058925).
Study intervention
All patients with non-traumatic cardiac arrest aged 18 or more were eligible for inclusion. Excluded patient were as follows: age below 18 years, pregnant women, traumatic cardiac arrest, hypothermic patient, drowned patient, patient who had additional extracorporeal CPR, patients who had achieved ROSC before the placement of NIRS device probes on the skin and if it was not possible to place NIRS probes on the patient within 5 min after start of ALS algorithm. Citeria for additional extracorporeal CPR are (all must be fulfilled): age < 55 years, witnessed cardiac arrest, appropriate BLS before ALS, primary shockable rhythm, unsuccessful advance life support resuscitation for at least 30 min (i.e., sustained/resistant ventricular fibrillation), estimated time to implantation of extracorporeal device less than 60 min from the time of collapse.
The team of doctor and two medical rescuers were dispatched by a health dispatcher after receiving information of a patient not showing signs of life. The doctor led resuscitation according to European Resuscitation Council guidelines for Advanced Life Support (ALS) [20, 21]. Immediately upon arrival, the prehospital team started with the ALS algorithm.
Tissue oxygenation measurement
As soon as possible, one of the team members placed NIRS probes on the patient. NIRS device (SenSmart Model X-100, Nonin Medical, Inc. Playmouth, Minnesota, USA), which records rSO2 every 4 s, and disposable self-adhesive probes (SenSmart Nonin Medical, Inc. Playmouth, Minnesota, USA) were used. Each probe was marked with color and always placed on the same part of the body: blue probe for brain and yellow for skeletal muscle. The blue probe for measuring brain rSO2 was placed on the patient’s right side of forehead and the yellow probe to the patient’s right hand thenar to measure skeletal muscle rSO2. The patient’s thenar was used due to our previous experimental and clinical experience [8]. The probes were additionally fixed with medical grade adhesive tape to avoid discontinuation of measurements. The NIRS device screen was not covered, so the team members could fix probe position in case of bad contact. As consequence this study was unblinded. However, teams had instructions that measured rSO2 values must not influence decisions made by the resuscitation team regarding termination of resuscitation or continuing one. The measurement stopped when the patient was admitted to the Emergency department or when the doctor declared death of the patient and CPR was terminated [22]. Return of spontaneous circulation (ROSC) was defined as return of spontaneous palpable pulse and or breathing, coughing, movement of the patient, rise of etCO2 for more than 30 s [22].
After intervention data were downloaded from the NIRS device by especially dedicated software (SenSmart, Version 1.0.1.0, Nonin Medical Inc., Minneapolis, MN USA) and paired with information from the intervention protocol. One of the graphs with measurements is presented in Fig. 1. Basal rSO2 was defined as an average of 4 measurements (average of rSO2 values in 16 s) of brain and skeletal muscle rSO2 after signal stabilization (approximately 12–16 s) after NIRS probes placement. We also recorded maximal rSO2 value during the CPR, difference between maximal–minimal rSO2 value (delta-rSO2), value of rSO2 at ROSC or the end of CPR with no-ROSC (end-CPR rSO2). rSO2 value of end-CPR rSO2 was average of 4 (16 s) measurements just before ROSC was confirmed or the resuscitation was terminated. Spiking signals, which were out of trend of the NIRS measurements, were considered as artefacts (Fig. 1) and we not included in analysis.
Additional data
The following additional data were recorded: basic demographic data (age, gender), the time of call to emergency telephone number (112), the time of arrival of the emergency team on scene, the time of ROSC/time of death, duration of CPR, was cardiac arrest witnessed, were eyewitnesses doing BLS (basic life support), the first ECG rhythm, use of AED, intubation status, number of defibrillations, cumulative dose of used adrenaline, ECG rhythm at the end of CPR/intervention and 28-day survival.
Primary outcome
Primary outcome was feasibility of skeletal muscle rSO2 measurement; how demanding is it to apply NIRS probes on two sites, what are the main problems of losing signal, how to fix the probes not to lose the signal.
Secondary outcome
The secondary outcome was to find out if there are any changes in measured skeletal muscle rSO2 during CPR and before/after ROSC. We also want to test the relationship between basal skeletal muscle rSO2 and time to start ALS in patients with witnessed cardiac arrest and without BLS. We also want to test relationship between skeletal muscle and brain rSO2.
Power analysis: no previously published data were available for specific NIRS device used in our study, that is why absolute difference of mean skeletal muscle rSO2 = 20% (SD 10%) between patients with ROSC and no-ROSC (ratio of sample size 1:3) was estimated in the first 10 recruited patients. For estimated error (Type I. error of 0.05, Type II. error of 0.20) total sample size of 16 patients (4 in ROSC, 12 in no-ROSC group) would be necessary.
Statistical analysis
The study population was divided into 2 groups according to outcome: ROSC and no-ROSC group. Continuous data were summarized as median (25th–75th quartile) compared by Mann–Whitney test for independent and Wilcoxon test for paired samples. Non-continuous data were summarized as the count (percentage). Chi-square test was used to compare non-continuous data. Rank correlation with Spearman's coefficient (rho) was used to test relationships between variables. Linear and non-linear regression methods was also used to test relationship between variables. MedCalc® ver. 20.104 (MedCalc Software Ltd) software was used for the statistical analysis. P value < 0.05 was regarded as statistically significant.
Results
Thirty patients were recruited. Ten patients were excluded due to different technical problems or violation of study protocol (Fig. 2): two patients due to disconnection of NIRS probe and consequent loss of skeletal muscle rSO2 signal during CPR; in four patients the probes were applied more than 5 min after arrival to the patient; in one patient probes were applied after ROSC; three patients were excluded due to irregular rSO2 signals, which have not allowed to determine predefined checkpoints.
Twenty patients with skeletal muscle rSO2 data were finally analyzed. In these patients, one patient had only skeletal muscle and no brain rSO2 recordings. Both skeletal muscle and brain rSO2 were recorded in 19 patients.
Basic demographic data, data about arrest and CPR are presented in Table 1. Twenty patients [age: 66.0 years (60.5–79.5), 65% male] with OHCA (50% witnessed, 70% with BLS), time to advance life support (ALS) 13.5 min (11.0–19.0) were finally analyzed. Cumulative dose of adrenaline was higher in no-ROSC group.
Measurement of skeletal muscle rSO2 and brain rSO2 are presented in Table 2. There was no statistically significant difference between the basal skeletal muscle and the basal brain rSO2 (17.5 (12.8–26.0) vs. 31.0 (15.8–41.6), P = 0.1674, respectively). Basal, maximal and end-CPR skeletal muscle rSO2 were higher in ROSC compared to no-ROSC group (49.0% (39.7–53.7) vs. 15.0% (12.0–25.2), P = 0.006; 76.0% (52.7–80.5) vs. 34.0% (18.0–49.5), P = 0.005; 72.0% (48.7–74.7) vs. 16.0% (12.0–35.0), P = 0.002, respectively) (Fig. 3). Delta rSO2 for skeletal muscle was not significantly different in patients with ROSC and no-ROSC group.
Basal brain rSO2 did not differ between ROSC and no-ROSC (38.0% vs. 29.5% (14.5–42.5), P = 0.4). Maximal, delta-rSO2 and end-CPR brain rSO2 were higher in ROSC compared to no-ROSC group (77% vs. 42.0% (30.5–53.0), P = 0.01; 27% vs. 10.5% (6.0–15.0), P = 0.007; 77% vs. 39.0% (29.7–52.7), P = 0.01, respectively) (Table 2).
There was non-linear cubic relationship between duration of collapse to establishment of NIRS monitoring and basal skeletal muscle rSO2 in witnessed OHCA and without BLS (F-ratio = 9.7713, P = 0.0261) (Fig. 4).
There was no correlation between basal rSO2, delta-rSO2 and end-CPR rSO2 of skeletal muscle and brain. There was a correlation between maximal skeletal muscle and brain rSO2 (n = 18, rho: 0.578, P = 0.0121), which was confirmed also in linear regression model (y = 25.245 + 0.499 x, r = 0.63, P = 0.005) (Fig. 5).
Discussion
The study confirmed the feasibility of monitoring skeletal muscle rSO2 in OHCA. Patients with ROSC had higher skeletal muscle rSO2 at the start of ALS (basal rSO2) and during CPR (maximal rSO2). There was a non-linear cubic relationship between basal rSO2 and time from collapse to start of rSO2 monitoring. There was also a linear relationship between the maximal values of skeletal muscle and brain rSO2.
During cardiac arrest there is decrease of rSO2, the value of decrease depends on the duration of no-flow/low flow and oxygen consumption of the tissue [8]. Basal skeletal muscle rSO2 is a surrogate for estimating the time of tissue low/no flow. Our study has shown a relationship between duration of witnessed cardiac arrest and basal skeletal muscle rSO2, which was, however, not significant due to low number of patients, because only patients with witnessed cardiac arrest and without BLS were include in that analysis. Basal skeletal muscle rSO2 were significantly different between ROSC and No ROSC groups, when all included patients were analyzed.
By rapid cuff inflation it is possible to stop flow through the arm, such as simulation of cardiac arrest, and evaluate skeletal muscle oxygen consumption. We have done this in patients with sepsis/septic shock and controls, aiming skeletal muscle rSO2 to decrease to 40% [23]. The rate of StO2 decrease during rapid cuff occlusion test was lower in septic shock patients compared to severe sepsis and controls (− 5 ± 2%/min vs. − 12 ± 2%/min vs. − 37 ± 7%/min, respectively; P < 0.001). In healthy volunteers we could measure rate of skeletal muscle rSO2 decrease during no-flow for longer period of time without any major risk, to explore skeletal muscle rSO2 kinetics and construct a normogram for estimating the duration of cardiac arrest for different age and gender groups.
In current study increase of skeletal muscle during resuscitation (delta rSO2) was not different between ROSC and No ROSC groups, this additionally emphasize the importance to start the resuscitation early as possible, when the basal skeletal muscle rSO2 (tissue oxygenation) is also still relatively high.
By additional fixation we have improved the position of NIRS probe on the thenar allowing more stable signal monitoring. The problem was big probe size, compared to thenar and higher possibility of detachment while manipulating patient’s hand. This fixation completely removed the possibility of losing contact and consequently signal during rSO2 monitoring even during different manipulations around and with the patient.
Despite the end of resuscitation (end-CPR rSO2) was different between ROSC and No-ROSC group, it is a very biased measure, since end-CPR by definition occurs much later in the no-ROSC group. This is a similar problem to the resuscitation-time bias seen in previous observational studies of the use of adrenaline during resuscitation from cardiac arrest [24,25,26]. End-CPR rSO2, furthermore, is an impracticable measure that cannot be used in a clinical relevant setting, because of the obvious fact that we cannot predict ROSC.
Brain rSO2 seems to be physiologically superior compared to other regional tissues. However, other rSO2, like kidney, are tested to give additional value to brain rSO2 during resuscitation in pediatric population [27, 28]. Monitoring of skeletal muscle rSO2 seem to be technically more reliably compared to brain rSO2, especially due to brain location in the body [19].
Several NIRS devices are available for clinical use. They differ according to numerous aspects, which include the algorithms adopted, the type of light source, the wavelengths of light emitted, the number and distance between the light emitters and detectors [19]. For example, INVOS system (5100C Cerebral/Somatic Oximeter; Medtronic, MN, USA) uses near-infrared light at two wavelengths [29]. Light travels from the light emitting diode of the sensor to either a proximal or distal detector, which allows separate data processing of shallow and deep optical signals. Data from the scalp and the surface tissue are subtracted and suppressed by spatial resolution, which reflects the rSO2 in deeper tissues [30]. The EQUANOX 7600 and also the SenSmart Model X-100 (Nonin Medical, MI, USA), the model that we have used, uses a dual light emitting and detecting sensor architecture, which has been shown to more effectively target the cerebral cortex and eliminate extracranial contamination from the scalp and skull. The Nonin system uses four wavelengths of near-infrared light. These added third and fourth wavelengths increase the accuracy of reporting the actual percent of oxygenated hemoglobin in the targeted tissues and can compensate for tissue factors that might otherwise reduce the accuracy of the measurements. This also allows the algorithm to reduce inter-subject variability, regardless of age, weight or skin color [30, 31]. We have previously shown high grade diversity of brain rSO2, with different NIRS devices, in patients with alkaptonuria, who had widespread tissue deposition of black pigment [19, 32, 33]. To guide our resuscitation efforts, we should probably not focus on only one modality, i.e., brain rSO2. Especially, because there is a report when good neurological outcome was achieved after prolonged CPR despite very low brain rSO2 [34].
Skeletal muscle rSO2 could also guide post-resuscitation care [17]. Continuous monitoring skeletal muscle rSO2 is already used in trauma patients and identifies the severity of shock [35]. Skeletal muscle rSO2 can track changes of systemic oxygen delivery during and after resuscitation of trauma patients or in patients heart failure patients/cardiogenic shock, who have preserved oxygen extraction [36]. New methods, such as near-infrared spectroscopy, which measures venous oxygen saturation in tissue from the near-infrared spectrum of the amplitude of respiration-induced absorption oscillations, may lead to the design of a non-invasive optical instrument capable of providing simultaneous and real-time measurements of local arterial, tissue and venous oxygen saturation.[37].
There was no statistically significant difference between the basal skeletal muscle and the basal brain rSO2, despite we would expect lower basal brain rSO2 due to higher cerebral oxygen consumption in normal human subjects compared to resting skeletal muscle oxygen consumption [38, 39]. There was also a very wide spread of basal rSO2. In pre-arrest state the patient could have centralization of flow to vital organ, and skeletal muscle rSO2 would be already low before cardiac arrest, as we previously have shown in patients with cardiogenic shock [8]. In our study, during resuscitation, there was lineal correlation between the maximal brain and skeletal muscle rSO2.
Repeatability of skeletal muscle rSO2 with NIRS during vascular occlusion test was confirmed in previous studies [40].
Limitations
Current study has at least four major limitations. First, the number of recruited patients is low despite long recruiting period. The main cause is the SARS-CoV-2 epidemics, during which the study was temporally stopped to minimize workload of staff in protective clothing. Second, the study was only single center study. Our data should be confirmed in a bigger prospective multicenter study. Third, low number of patients with ROSC, did not allow to study time change of skeletal muscle rSO2 during resuscitation and prognostic value of skeletal muscle rSO2 for good neurological outcome. The fourth, study was not designed to study use of skeletal muscle rSO2 as post-resuscitation therapy guide and non-invasive estimation of adequacy of flow. It should be done in other multicenter study.
Conclusions
Recording of skeletal muscle rSO2 during CPR in patients with OHCA is feasible. Basal and maximal skeletal muscle rSO2 were higher in ROSC compared to no-ROSC group. Skeletal muscle rSO2 during cardiac arrest could provide additional data to brain rSO2 on duration of arrest and efficiency of resuscitation efforts.
Availability of data and materials
The data sets used and/or analyzed during the current study are available from the corresponding author on reasonable request.
Change history
16 November 2023
A Correction to this paper has been published: https://doi.org/10.1186/s40001-023-01517-5
Abbreviations
- NIRS:
-
Near-infrared spectroscopy
- OHCA:
-
Out of hospital cardiac arrest
- ROSC:
-
Return of spontaneous circulation
- CPR:
-
Cardiopulmonary resuscitation
- BLS:
-
Basic life support
- ALS:
-
Advanced life support
- rSO2 :
-
Regional tissue oxygen saturation
References
Grasner JT, Bottiger BW, Bossaert L, European Registry of Cardiac Arrest ONESC, EuReCa ONESMT. EuReCa ONE-ONE month-ONE Europe-ONE goal. Resuscitation. 2014;85(10):1307–8.
Sasson C, Rogers MA, Dahl J, Kellermann AL. Predictors of survival from out-of-hospital cardiac arrest: a systematic review and meta-analysis. Circ Cardiovasc Qual Outcomes. 2010;3(1):63–81.
Sandroni C, Cariou A, Cavallaro F, Cronberg T, Friberg H, Hoedemaekers C, et al. Prognostication in comatose survivors of cardiac arrest: an advisory statement from the European Resuscitation Council and the European Society of Intensive Care Medicine. Resuscitation. 2014;85(12):1779–89.
Cournoyer A, Iseppon M, Chauny JM, Denault A, Cossette S, Notebaert E. Near-infrared spectroscopy monitoring during cardiac arrest: a systematic review and meta-analysis. Acad Emerg Med. 2016;23(8):851–62.
Možina H. Tkivna oksigenacija skeletne mišice pri kritično bolnih: doktorska disertacija [disertacija]. [S. l. : H. Možina], 2015: Univerza v Mariboru; 2015.
Jones S, Chiesa ST, Chaturvedi N, Hughes AD. Recent developments in near-infrared spectroscopy (NIRS) for the assessment of local skeletal muscle microvascular function and capacity to utilise oxygen. Artery Res. 2016;16:25–33.
Prosen G, Strnad M, Doniger SJ, Markota A, Stozer A, Borovnik-Lesjak V, et al. Cerebral tissue oximetry levels during prehospital management of cardiac arrest—a prospective observational study. Resuscitation. 2018;129:141–5.
Mozina H, Podbregar M. Near-infrared spectroscopy during stagnant ischemia estimates central venous oxygen saturation and mixed venous oxygen saturation discrepancy in patients with severe left heart failure and additional sepsis/septic shock. Crit Care. 2010;14(2):R42.
Genbrugge C, Meex I, Boer W, Jans F, Heylen R, Ferdinande B, et al. Increase in cerebral oxygenation during advanced life support in out-of-hospital patients is associated with return of spontaneous circulation. Crit Care. 2015;19:112.
Schnaubelt S, Sulzgruber P, Menger J, Skhirtladze-Dworschak K, Sterz F, Dworschak M. Regional cerebral oxygen saturation during cardiopulmonary resuscitation as a predictor of return of spontaneous circulation and favourable neurological outcome—a review of the current literature. Resuscitation. 2018;125:39–47.
Singer AJ, Ahn A, Inigo-Santiago LA, Thode HC Jr, Henry MC, Parnia S. Cerebral oximetry levels during CPR are associated with return of spontaneous circulation following cardiac arrest: an observational study. Emerg Med J. 2015;32(5):353–6.
Parnia S, Nasir A, Shah C, Patel R, Mani A, Richman P. A feasibility study evaluating the role of cerebral oximetry in predicting return of spontaneous circulation in cardiac arrest. Resuscitation. 2012;83(8):982–5.
Genbrugge C, De Deyne C, Eertmans W, Anseeuw K, Voet D, Mertens I, et al. Cerebral saturation in cardiac arrest patients measured with near-infrared technology during pre-hospital advanced life support. Results from Copernicus I cohort study. Resuscitation. 2018;129:107–13.
Sakaguchi K, Takada M, Takahashi K, Onodera Y, Kobayashi T, Kawamae K, et al. Prediction of return of spontaneous circulation during cardiopulmonary resuscitation by pulse-wave cerebral tissue oxygen saturation: a retrospective observational study. BMC Emerg Med. 2022;22(1):30.
Frisch A, Suffoletto BP, Frank R, Martin-Gill C, Menegazzi JJ. Potential utility of near-infrared spectroscopy in out-of-hospital cardiac arrest: an illustrative case series. Prehosp Emerg Care. 2012;16(4):564–70.
Kalkan A, Bilir O, Ersunan G, Ozel D, Tas M, Memetoglu ME. Abdominal oxygen saturation for monitoring return of spontaneous circulation in out-of-hospital cardiac arrest using near infrared spectrophometry. Am J Emerg Med. 2015;33(3):344–8.
Mozina H, Podbegar M. Near-infrared spectroscopy for evaluation of global and skeletal muscle tissue oxygenation. World J Cardiol. 2011;3(12):377–82.
Thomassen SA, Kjaergaard B, Sorensen P, Andreasen JJ, Larsson A, Rasmussen BS. Regional muscle tissue saturation is an indicator of global inadequate circulation during cardiopulmonary bypass: a randomized porcine study using muscle, intestinal and brain tissue metabolomics. Perfusion. 2017;32(3):192–9.
Kovac P, Mis K, Pirkmajer S, Mars T, Klokocovnik T, Kotnik G, et al. How to measure tissue oxygenation using near-infrared spectroscopy in a patient with alkaptonuria. J Cardiothorac Vasc Anesth. 2018;32(6):2708–11.
Soar J, Nolan JP, Bottiger BW, Perkins GD, Lott C, Carli P, et al. European Resuscitation Council Guidelines for Resuscitation 2015: Section 3. Adult advanced life support. Resuscitation. 2015;95:100–47.
Soar J, Bottiger BW, Carli P, Couper K, Deakin CD, Djarv T, et al. European resuscitation council guidelines 2021: adult advanced life support. Resuscitation. 2021;161:115–51.
Jacobs I, Nadkarni V, Bahr J, Berg RA, Billi JE, Bossaert L, et al. Cardiac arrest and cardiopulmonary resuscitation outcome reports: update and simplification of the Utstein templates for resuscitation registries: a statement for healthcare professionals from a task force of the International Liaison Committee on Resuscitation (American Heart Association, European Resuscitation Council, Australian Resuscitation Council, New Zealand Resuscitation Council, Heart and Stroke Foundation of Canada, InterAmerican Heart Foundation, Resuscitation Councils of Southern Africa). Circulation. 2004;110(21):3385–97.
Pareznik R, Knezevic R, Voga G, Podbregar M. Changes in muscle tissue oxygenation during stagnant ischemia in septic patients. Intensive Care Med. 2006;32(1):87–92.
Andersen LW, Grossestreuer AV, Donnino MW. “Resuscitation time bias”—a unique challenge for observational cardiac arrest research. Resuscitation. 2018;125:79–82.
Gough CJR, Nolan JP. The role of adrenaline in cardiopulmonary resuscitation. Crit Care. 2018;22(1):139.
Perkins GD, Kenna C, Ji C, Deakin CD, Nolan JP, Quinn T, et al. The influence of time to adrenaline administration in the paramedic 2 randomised controlled trial. Intensive Care Med. 2020;46(3):426–36.
Harer MW, Chock VY. Renal tissue oxygenation monitoring-an opportunity to improve kidney outcomes in the vulnerable neonatal population. Front Pediatr. 2020;8:241.
Mebius MJ, du Marchie Sarvaas GJ, Wolthuis DW, Bartelds B, Kneyber MCJ, Bos AF, et al. Near-infrared spectroscopy as a predictor of clinical deterioration: a case report of two infants with duct-dependent congenital heart disease. BMC Pediatr. 2017;17(1):79.
Abdul-Khaliq H, Troitzsch D, Berger F, Lange PE. Regional transcranial oximetry with near infrared spectroscopy (NIRS) in comparison with measuring oxygen saturation in the jugular bulb in infants and children for monitoring cerebral oxygenation. Biomed Tech (Berl). 2000;45(11):328–32.
Robu CB, Koninckx A, Docquier MA, Grosu I, De Kerchove L, Mastrobuoni S, et al. Advanced age and sex influence baseline regional cerebral oxygen saturation as measured by near-infrared spectroscopy: subanalysis of a prospective study. J Cardiothorac Vasc Anesth. 2020;34(12):3282–9.
Bickler PE, Feiner JR, Rollins MD. Factors affecting the performance of 5 cerebral oximeters during hypoxia in healthy volunteers. Anesth Analg. 2013;117(4):813–23.
Argiriadou H, Anastasiadis K, Antonitsis P, Kanyamimboua D, Karapanagiotidis G, Papakonstantinou C. The inability of regional oxygen saturation monitoring in a patient with alkaptonuria undergoing aortic valve replacement. J Cardiothorac Vasc Anesth. 2009;23(4):586–8.
Liu W, Prayson RA. Dura mater involvement in ochronosis (alkaptonuria). Arch Pathol Lab Med. 2001;125(7):961–3.
Koyama Y, Inoue Y, Hisago S, Marushima A, Hagiya K, Yamasaki Y, et al. Improving the neurological prognosis following OHCA using real-time evaluation of cerebral tissue oxygenation. Am J Emerg Med. 2018;36(2):344e5-e7.
Crookes BA, Cohn SM, Bloch S, Amortegui J, Manning R, Li P, et al. Can near-infrared spectroscopy identify the severity of shock in trauma patients? J Trauma. 2005;58(4):806–13 (discussion 13-6).
McKinley BA, Marvin RG, Cocanour CS, Moore FA. Tissue hemoglobin O2 saturation during resuscitation of traumatic shock monitored using near infrared spectrometry. J Trauma. 2000;48(4):637–42.
Franceschini MA, Boas DA, Zourabian A, Diamond SG, Nadgir S, Lin DW, et al. Near-infrared spiroximetry: noninvasive measurements of venous saturation in piglets and human subjects. J Appl Physiol (1985). 2002;92(1):372–84.
Mintun MA, Raichle ME, Martin WR, Herscovitch P. Brain oxygen utilization measured with O-15 radiotracers and positron emission tomography. J Nucl Med. 1984;25(2):177–87.
Heinonen I, Saltin B, Kemppainen J, Sipila HT, Oikonen V, Nuutila P, et al. Skeletal muscle blood flow and oxygen uptake at rest and during exercise in humans: a pet study with nitric oxide and cyclooxygenase inhibition. Am J Physiol Heart Circ Physiol. 2011;300(4):H1510–7.
Strahovnik I, Podbegar M. Measurement of skeletal muscle tissue oxygenation in the critically ill. Signa Vitae. 2008;3(1):43–50.
Acknowledgements
We thank the medical staff of the Emergency Unit of Community Health Centre Ljubljana and the Rescue station of University Medical Centre Ljubljana to recruit patients.
Funding
The research was supported by tertiary grant, number 20200211 form University Medical Centre Ljubljana, Slovenia.
Author information
Authors and Affiliations
Contributions
Author contributions are as follows: primary author MK was involved in idea and setting the protocol, recruiting patients, analyzing data and drafting the manuscript; MP was involved in idea and setting the protocol, analyzing data and finalizing the manuscript; HM was involved in idea and setting the protocol, supervised the study, applied for funding and finalizing the manuscript. All authors read and approved the final manuscript.
Corresponding author
Ethics declarations
Ethics approval and consent to participate
The research protocol received approval by Slovenian Medical Ethics Committee (No. 0120-334/2019/3); patients’ consent was waived because of the observational nature of the study and emergency setting.
Consent for publication
Not applicable.
Competing interests
The authors declare that they have no competing interests.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
The original online version of this article was revised: The given and family names of all the authors were swapped and published incorrectly as Košir Miha, Možina Hugon and Podbregar Matej instead of Miha Košir, Hugon Možina and Matej Podbregar.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
About this article
Cite this article
Košir, M., Možina, H. & Podbregar, M. Skeletal muscle oxygenation during cardiopulmonary resuscitation as a predictor of return of spontaneous circulation: a pilot study. Eur J Med Res 28, 418 (2023). https://doi.org/10.1186/s40001-023-01393-z
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s40001-023-01393-z