Abstract
Background
Intravenous misplacement of a nephrostomy tube is a rare complication of percutaneous nephrolithotomy (PCNL) or percutaneous nephrostomy. The mechanism of misplacement of a nephrostomy tube into the vascular system is seldom investigated. One type of the possible mechanism is that the puncture needle penetrates a major intrarenal tributary of the renal vein and enters the collecting system. However, the guidewire is located outside the collecting system near the large branches of renal vein or perforates into the renal vein. The dilation is performed and causes a large torn injury. Subsequently, the nephrostomy tube is placed inside the vessel when radiological monitoring is not used. However, there is no imaging evidence and the scene of procedure is not demonstrated. This paper reports two cases of visualization of the renal vein filled with contrast agent during PCNL. The findings may be good evidence to support the step of renal vein injury in patients with intravenous nephrostomy tube misplacement.
Case presentation
We presented two cases with visualization of the renal vein filled with contrast agent during PCNL. In the process of injecting the contrast agent through the puncture needle, we could see the renal vein. Moreover, it was identified that the puncture needle tip was not on the optimal position. The position of puncture needle tip lay outside the collecting system, which was close to the calyceal infundibulum and branches of renal vein.
Conclusions
Visualization of the renal vein filled with contrast agent may be good evidence to verify the renal vein injury in patients with intravenous nephrostomy tube misplacement during PCNL or percutaneous nephrostomy. The suboptimal location of the puncture needle tip and visualization of the renal vein filled with contrast agent indicate the renal vein injury. One type of mechanism of intravenous nephrostomy tube misplacement is as following. Firstly, the guidewire stays outside the collecting system. Subsequently, dilatation directed by the guidewire results in the injury of the vein. Then, the nephrostomy tube migrates into the venous system due to prompt tube inserting and the direction of the sheath and/or the guidewire to the injured vein.
Similar content being viewed by others
Explore related subjects
Find the latest articles, discoveries, and news in related topics.Background
Intravenous misplacement of a nephrostomy tube is a rare event of percutaneous nephrolithotomy (PCNL) or percutaneous nephrostomy (PCN) [1,2,3,4,5,6]. Limited literatures have reported the misplacement of a nephrostomy tube in the renal vein, inferior vena cava (IVC) or atrium. The mechanisms of misplacement of a nephrostomy tube into the vascular system are also seldom investigated. One type of the possible mechanism is that the puncture needle penetrates a major intrarenal tributary of the renal vein and enters the collecting system. However, the guidewire is located outside the collecting system near the large branches of renal vein or perforates into the renal vein. The dilation is performed and causes a large torn injury. Subsequently, the nephrostomy tube is placed inside the vessel when radiological monitoring is not used [6, 9]. However, there is no imaging evidence and the scene of procedure is not demonstrated.
In the present study, we report two cases of visualization of the renal vein filled with contrast agent during PCNL at our centers. The findings may be good evidence to support the step of renal vein injury in patients with intravenous nephrostomy tube misplacement.
Case presentation
Patient 1 was a 45-year-old man who presented with left flank pain. His medical history indicated that he had renal stone. His physical examination was positive for tenderness upon palpation of his left flank. The initial laboratory evaluation showed normal. The computed tomography (CT) scan of abdomen and pelvis showed left moderate hydronephrosis and an upper ureteral stone was measured at 1.3 cm. Our patient was diagnosed with left upper ureteral stone with moderate hydronephrosis. The procedure of PCNL was carried out. A ureteral catheter was inserted retrogradely into the left pelvic under ureteroscopy. The puncture target calix was the middle posterior calix. The puncture site of the target calyceal fornix was localized under C-arm radiological monitoring using contrast agent injected through ureteral catheter, producing a retrograde pyelography (RP). An 18 gauge, 2 piece entry needle was used. Clear urine was seen when the needle stylet was removed. When we injected the contrast agent into his left collecting system through the puncture needle, we were able to see his left renal vein (Fig. 1). Moreover, we could identify that the location of the puncture needle tip was not optimal, the reason was that the puncture needle tip was located outside the collecting system near the calyceal infundibulum. At the moment, the patient had a hemodynamic stability and the puncture needle was maintained in its original place. Additional lower pole calix puncture was performed under radiological monitoring. Clear urine was also seen when the needle stylet was removed. Injection of contrast agent in his left collecting system through the later puncture needle showed the collecting system, without visualization of the renal vein (Fig. 2). In the process of injecting saline into his left collecting system by ureteral catheter, we were able to see the light red drips through the former puncture needle, and the clear drips through the latter puncture needle. The former puncture needle was pulled out and simultaneous PCNL was performed. An 18 gauge, 2 piece entry needle was advanced into the lower pole calix under fluoroscopy guidance. A zebra guidewire was inserted into the collecting system. The tract was dilated with fascial dilators to accommodate an 18 French sheath. The renal calculus was removed uneventfully.
Patient 2 was a 41-year-old woman who presented with left flank pain. Her medical history was unremarkable. White blood cells were detected in the urine. Empirical antibiotics were started. A CT scan of abdomen and pelvis showed the presence of left mild hydronephrosis and renal calculi was measured at 2.2 cm. The patient was diagnosed with renal calculi and mild hydronephrosis. A PCNL procedure protocol was planned. A ureteral catheter was inserted into the left ureter retrogradely. The target calix was the middle posterior calix. The puncture site of the target calyceal fornix was localized under fluoroscopy monitoring using contrast agent injected through ureteral catheter, producing a RP. Clear urine was seen on withdrawal of the stylet. During an injection of contrast agent in her left collecting system through the puncture needle, we were able to visualize her left renal vein filled with contrast agent (Fig. 3). We could also identify that the location of the puncture needle tip was not optimal. The puncture needle tip was near the calyceal infundibulum. The puncture needle was pulled out. A puncture tract passing through the middle posterior caliceal fornix was performed simultaneously and the renal calculi was removed uneventfully. The operative steps were as same as patient 1.
Among our two patients, we saw the renal vein filled with contrast agent during PCNL and identified the location of the puncture needle tip was not optimal. The puncture needle tip was located outside the collecting system near the calyceal infundibulum in the two patients. The visualization of renal vein branches during antegrade pyelography and bloody fluid drips confirmed the puncture needle tips located in a vein vessel or injured a vessel. The following procedures were not carried out. The original operation PCNL was performed successfully by another puncture tract in the two patients. They were discharged uneventfully with the stones cleaned by simultaneous PCNL.
Six articles relevant to the vein injury during PCN or PCNL were selected [3, 5,6,7,8,9]. The data of the six articles were summarized in Table 1. As noted in Table 1, the vein injury in patient undergoing PCN occurred in the initial stage of the operation. The guidewire or catheter perforated and migrated into the vein directly. In patient undergoing PCNL, the vein injury occurred either in the initial stage due to the dilator tearing motion or during the operation due to the fragmentation energy.
Discussion and conclusions
Intravenous tube misplacement is a rare complication of PCNL or PCN with the incidence of 0.02–0.05% [6, 9].
Three types of mechanism of intravenous tube misplacement were mentioned in literatures. The first type of mechanism was described by Chen et al. [6] and Fu et al. [9]. Firstly, the puncture needle passes through a branch of renal vein and its tip enter the collecting system. During inserting the guidewire through the puncture needle, the tip of puncture needle moves outside of the collecting system due to such factors as respiratory movement, narrow space between staghorn calculi and collecting system. The guidewire stays just outside the collecting system near the injured renal vein branch or perforates into the renal vein. If the misplaced improper location of guidewire is not recognized by the surgeon. Dilatation directed by the guidewire results in a torn lesion of the vein. Heavy venous bleeding occurs as soon as the dilator is removed. The nephrostomy tube migrates into the vascular system due to the prompt tube inserting and the direction of the sheath and\or the guidewire to the injured vein.
The second type of mechanism is as Mazzucchi et al. [5] and Wang et al. [7] describes. Firstly, the instruments used during surgery cause a lesion in a large branch of renal vein. Secondly, the sheath directs the nephrostomy tube inside the vascular system. The third mechanism can be observed in catheter placement [3, 8]. Firstly, the nephrostomy tube or the guidewire perforates a major branch of the renal vein. Then, the tube is placed inside the vessel directly, or guided by the guidewire.
Here we provide two patients with the imaging evidence and the scene of procedure demonstration to verify the renal vein injury in the first mechanism. In our patients 1 and 2 the location of the puncture needle tip was not optimal. We are able to visualize the renal vein and collecting system during an injection of contrast agent through the puncture needle. It indicates that the tip of puncture needle has pass through the branch of the renal vein and enters into the collecting system initially. However, during fluoroscopic imaging the tip of puncture needle moves outside of the collecting system. It stays near or inside the branch of the renal vein outside the collecting system. If the guidewire is inserted through the puncture needle, it will just stay outside the calix or perforate into the renal vein. Dilatation directed by the guidewire will result in the injury of the vein. The nephrostomy tube will migrate into the vascular system directed by the dilator sheath and\or the guidewire. To prevent such complication, review of previous imaging, including ultrasound, CT, or magnetic resonance imaging should be performed, to identify valuable anatomic information as to the optimal access entrance before establishing percutaneous access. The ideal entrance point should be along the avascular plane of Brodel in a position that is lateral to the renal calyx, and directed toward the renal pelvis. The puncture tract should pass through the caliceal fornix. After the tip of the needle is confirmed within the collecting system under ultrasound or fluoroscopy guidance. The tip of the needle should be maintained in the initial position with the needle depth no changing. Then, a guidewire is carefully and gently inserted into the renal collecting system. The guidewire should be also confirmed curling in the renal collecting system under ultrasound or fluoroscopy guidance.
In conclusion, visualization of the renal vein filled with contrast agent may be good evidence to verify the renal vein injury in patients with intravenous nephrostomy tube misplacement during PCNL or PCN. The suboptimal location of the puncture needle tip and visualization of the renal vein filled with contrast agent indicate the renal vein injury. One type of mechanism of intravenous nephrostomy tube misplacement is as following. Firstly, the guidewire stays outside the collecting system. Subsequently, dilatation directed by the guidewire results in the injury of the vein. Then, the nephrostomy tube migrates into the venous system due to prompt tube inserting and the direction of the sheath and\or the guidewire to the injured vein.
Availability of data and materials
Not applicable.
Abbreviations
- CT:
-
Computed tomography
- IVC:
-
Inferior vena cava
- PCNL:
-
Percutaneous nephrolithotomy
- PCN:
-
Percutaneous nephrostomy
- RP:
-
Retrograde pyelography
References
Mirheydar HS, Palazzi KL, Derweesh IH, Chang DC, Sur RL. Percutaneous nephrolithotomy use is increasing in the United States: an analysis of trends and complications. J Endourol. 2013;27:979–83.
Taylor E, Miller J, Chi T, Stoller ML. Complications associated with percutaneous nephrolithotomy. Transl Androl Urol. 2012;1:223–8.
Dias-Filho AC, Coaracy GA, Borges W. Right atrial migration of nephrostomy catheter. Int Braz J Urol. 2005;31:470–1.
Shaw G, Wah TM, Kellett MJ, Choong SK. Management of renal vein perforation during a challenging percutaneous nephrolithotomy. J Endourol. 2005;19:722–3.
Mazzucchi E, Mitre A, Brito A, Arap M, Murta C, Srougi M. Intravenous misplacement of the nephrostomy catheter following percutaneous nephrostolithotomy: two case reports. Clinics (Sao Paulo). 2009;64:69–70.
Chen XF, Chen SQ, Xu LY, Gong Y, Chen ZF, Zheng SB. Intravenous misplacement of nephrostomy tube following percutaneous nephrolithotomy: three new cases and review of seven cases in the literature. Int Braz J Urol. 2014;40:690–6.
Wang C, Chen S, Tang F, Shen B. Metachronous renal vein and artery injure after percutaneous nephrostolithotomy. BMC Urol. 2013;13:1–5.
Kotb AF, Elabbady A, Mohamed KR, Atta MA. Percutaneous silicon catheter insertion into the inferior vena cava, following percutaneous nephrostomy exchange. Can Urol Assoc J. 2013;7:e505–7.
Fu W, Yang Z, Xie Z, Yan H. Intravenous misplacement of the nephrostomy catheter following percutaneous nephrostolithotomy: two case reports and literature review. BMC Urol. 2017;17:43.
Acknowledgements
We also thank the two patients for giving us the permission to use the medical information for this publication.
Funding
Not applicable.
Author information
Authors and Affiliations
Contributions
XFC drafted the manuscript. WLD was responsible for critical revision of the manuscript. JMS, GCC and YHZ performed the operation. JJZ was responsible for the conception and design of this study, interpretation of the data. All authors read and approved the final manuscript.
Corresponding author
Ethics declarations
Ethics approval and consent to participate
Not applicable.
Consent for publication
Written informed consent was obtained from two cases for publication of this Case Report and any accompanying images. A copy of the written consent is available for review by the Editorial team of this journal.
Competing interests
The authors declare that they have no competing interests.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
About this article
Cite this article
Chen, XF., Zhou, JJ., Sun, JM. et al. Visualization of the renal vein filled with contrast agent may indicate the renal vein injury during percutaneous nephrolithotomy: two case reports. BMC Urol 21, 105 (2021). https://doi.org/10.1186/s12894-021-00868-7
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s12894-021-00868-7