Introduction

Aphakia means that the lens leaves the normal position and loses its original function, including absence or complete dislocation and subluxation of the lens [1]. This disease could cause anisometropic amblyopia, strabismus, and loss of binocular function in children and adolescents. For adults, the loss of the lens could lead to high hyperopia and affect vision. Aphakia has many causes, such as cataract surgery for lens posterior capsule injury (60%–75%); exogenous factors, such as lens injury during vitreoretinal surgery (8%–15%); and endogenous factors, such as Marfan syndrome, pseudo exfoliation syndrome, and idiopathic lens dislocation (15%–30%) [2,3,4,5].

At present, surgery is generally chosen in the clinical treatment of aphakic eyes. The conventional surgical procedures are as follows: anterior chamber intraocular lens implantation (AC-IOL), iris fixed intraocular lens implantation (IF-IOL), and scleral fixed intraocular lens implantation (SF-IOL). SF-IOL is divided into suture SF-IOL, glued SF-IOL, and sutureless SF-IOL. AC-IOL has been rarely used in clinic because it may lead to chamber angle injury, corneal endothelial injury, and even irreversible corneal endothelial decompensation. IF-IOL could be fixed by suture or without suture. Iris claw intraocular lens implantation, a kind of seamless intraocular lens, places the polymethyl methacrylate intraocular lens on the anterior surface of the iris and wraps the tactile device in the non-vascular part of the iris far away from the corneal endothelium and the iris angle [6]. The methods of suture and fixation include McCannel suture technique and Siepser sliding conjunctival suture technique [7, 8]. At present, this method still has good safety, and it is widely used in clinic. Suture SF-IOL is sutured to the sclera with 10–0 polypropylene or 9–0 polypropylene or expanded polytetrafluoroethylene suture [9]. Although suture fixation may induce complications, such as suture fracture and suture erosion [10, 11], with the continuous progress of science and technology, the procedure of this operation is constantly simplified and the injury is decreasing, hence the operation method that many clinical scholars are willing to choose. Glued SF-IOL effectively avoids the possible complications caused by suture by using fibrin glue to fix the IOL loop under the scleral flap or in the scleral tunnel. However, due to the high cost of fibrin glue and possible postoperative prion-related infection [12, 13], the scope of application of this operation is limited. Compared with the previously described surgery, sutureless SF-IOL greatly reduces tissue injury, reduces the incidence of postoperative complications, and shortens the postoperative recovery time by implanting the IOL loop into an artificially established scleral tunnel because it does not require suture, adhesion, and scleral cauterization [14]. In view of the above advantages, sutureless SF-IOL has become the mainstream surgical scheme for the clinical treatment of aphakic eyes.

However, no study has comprehensively compared the efficacy and safety of sutureless SF-IOL with suture SF-IOL. The present paper aimed to compare the relationship among different surgical methods and operation times, postoperative visual acuities, postoperative refractive states, postoperative intraocular lens inclinations, and postoperative complications to provide reference for follow-up clinical research.

Materials and methods

Literature about sutureless SF-IOL in PubMed, Cochrane Library, Embase, Web of Science, China National Knowledge Infrastructure (CNKI), China Technical Journal (VIP) database, and Wanfang database published from 2000 to 2022 was reviewed. The weighted average difference (WMD) was calculated by RevMan5.3 software for analysis. Two researchers independently selected the study and used the Cochrane collaboration tool to assess the risk of errors. Cochrane bias risk tool was used to evaluate the quality of evidence.

Search strategy

The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA, 2020) search strategy flow chart and checklist were used as guides in identifying and selecting relevant studies in EMBASE, Web of Science, Cochrane Library, PubMed, CNKI, VIP database, and WanFang database. All the searches were performed before February 2023. The search strategy included the following words and phrases: “(flanged intrascleral fixation) OR (SFIOL) OR (sutureless intraocular lens) OR (suture-free intraocular lens) OR (transconjunctival sutureless intrascleral fixation) OR (SFIOL).” Study selection was restricted to English and Chinese languages.

Study selection

The selection criteria for this meta-analysis are as follows: 1) All studies should be designed with randomized controlled trials (RCT) or Non-randomised studies of the effects of interventions (NRSI). 2) All studies should be designed with prospective studies or retrospective studies with raw data. 3) Aphakia eyes were fixed with posterior chamber intraocular lens without suture and with glue-free sclera. 4) The prognosis should be evaluated by postoperative visual acuity best corrected visual acuity (BCVA), corrected distance visual acuity (CDVA), uncorrected visual acuity (UCVA), postoperative refractive status (myopia, hyperopia, and astigmatism), or intraocular lens inclination (°). The exclusion criteria are as follows: 1) review or meta-analysis articles; 2) no suture-free scleral fixation of posterior chamber intraocular lens; 3) reports of repetitive data articles; 4) postoperative visual acuity (BCVA, CDVA, and UCVA), absolute postoperative spherical equivalent, astigmatism(IOL-related astigmatism and surgery induce astigmatism), intraocular lens inclination (horizontal and vertical), refractive prediction error,or incidence of complications were not reported in the article.

Data extraction

Two reviewers (Zhao Liu and Bing Xie) independently extracted data from each article. First, numerical data from tables, text, or figures were extracted. If these were not reported, data from graphs were extracted using a digital ruler software. In case data were not reported or unclear, authors were contacted by e-mail (maximum of two attempts). In case an outcome was measured at multiple timepoints, the data from the timepoint where efficacy was the highest were included. The following study identifiers were collected: title, author, design, number of eyes, country of origin, and publication year. At baseline, cohort age and sex distribution were collected. Outcomes were analyzed at final follow-up and included CDVA, BCVA, UCVA (Logmar Visual Acuity), postoperative visual acuity change, operation time, intraocular lens inclination (horizontal and vertical), absolute postoperative spherical equivalent, astigmatism (IOL-related astigmatism and surgery induce astigmatism), refractive prediction error, and incidence of complications. Logmar visual acuity was selected for analysis in this study.

Methodological quality and assessment of studies

Cochrane Handbook for Systematic Reviews of Interventions: Several aspects of the included studies were assessed by the two researchers: random sequence generation, allocation concealment, blinding of participants and personnel, blinding of outcome assessment, incomplete outcome data, selective reporting, and other biases. A level of “high,” “low,” or “unclear” was given for each item [15].

Data analysis

RevMan 5.3 was used to analyze the data and generate forest and funnel plots. The pooled estimate was reported as weighted mean differences (WMDs) with 95% confidence intervals (Cis) for continuous outcomes. Either the fixed-effect or random-effect model was used to pool the effect sizes. If I2 < 50% and p ≥ 0.1, the pooled outcomes were calculated by the fixed-effect model; otherwise, the random-effect model was applied. Stata 15.1 software was used to check publication bias, which was assessed using the funnel plots and Egger and Begg’s tests. Heterogeneity tests, including Q and I2 statistics, were calculated; 25%, 50%, and 75% I2 scores were considered low, moderate, and high heterogeneities, respectively. Subgroup analysis was categorized in accordance with surgical method.

Results

Study selection and characteristics

In this study, 470, 32, 527, 479, 21, 10, and 33 articles were retrieved from PubMed, Cochrane, Embase, Web of Science, CNKI, VIP, and Wanfang database, respectively, with a total of 1572 articles. Finally, 14 articles (including 15 studies) met the inclusion criteria, including one in Chinese and 13 in English. The selected scheme for literature retrieval and research is shown in Fig. 1.

Fig. 1
figure 1

Flow diagram of selection studies

Of the 1572 articles, 450 repetitive articles and 40 reviews/meta-analyses were deleted. After the title and abstract were screened, 672 articles were excluded after review of title. After reports sought for retrieval, 331 articles that were not related to sutureless SF-IOL were excluded. Finally, 79 articles were obtained for further research. A total of 65 articles were excluded as follows: six articles not related to sutureless SF-IOL,52 articles without control group and without sutureless SF-IOL and 7 articles that the control group was the study of IF-IOL or Glued SF-IOL. The earliest inclusion study was published in 2013. These articles are distributed in 10 countries: India, Turkey, South Korea, Poland, Japan, Germany, Brazil, Thailand, the United States, and China.Because the Daniel.et al.2021 [16] provided two control groups: one using Gore-Tex sutures and the other using Prolene sutures, this article provides two comparative studies.

Overall, 15 studies were included (14 articles), of which 13 were retrospective studies and two were prospective studies. A total of 817 eyes were examined in these 15 studies. Among them, 403 eyes underwent sutureless SF-IOL, 414 eyes underwent suture SF-IOL. A total of 420 (63.2%) and 244 (36.8%) men and women were included in the 14 studies, respectively. The average ages of patients who underwent sutureless SF-IOL and suture SF-IOL were 55.68 (4.80–76.04 years), 56.24 (14.33–72.87 years), respectively (Table 1). The surgical procedures and suture materials used in each study are listed in Table 2. The inclusion criteria and exclusion criteria of all studies are listed in Table 3. The average follow-up times of patients who underwent sutureless SF-IOL and suture SF-IOL were 11.84 (1.00–37.86 months) and 10.50 (1.00–17.28 months), respectively (Table 4).

Table 1  Basic information of all researches
Table 2 Summary of operation methods, suture type and scope of vitrectomy
Table 3 Inclusion criteria and exclusion criteria of all researches
Table 4 Summary of follow-up in all researches

Methodologies for the bias of selected studies

The quality of the included studies is shown in Fig. 2. Kyu.et al.2021 [17] and Manavi.et al.2016 [18] were listed as high risk because the choice of surgery was based on the surgeon's preference. Except for Bruna.et al.2019 [19] and Jae.et al.2020 [20], other studies clearly reported the use of random sequence generation. Due to the lack of information on these studies, assessing the hidden risk bias of allocation is not possible. Every medical worker does not inform patients about the treatment plans of other patients to protect the privacy of patients, so the risk of bias in the study is low. The results of the study were measured and registered by the researchers, but information was not sufficient to assess the risk bias of blind outcome assessments. No significant data loss or follow-up loss was reported in all studies, so the risk of bias is low. The reporting items in all the studies are complete, without missing reporting items and results, so the risk of reporting bias is low. Overall, no clear indication of other types of bias was observed.

Fig. 2
figure 2

Risk of bias summary: review authors’ judgments about each risk of bias item for each included study

Data analysis

Visual acuity (Logmar Visual Acuity)

BCVA

The BCVA after sutureless SF-IOL and suture SF-IOL were compared (WMD =  − 0.00, 95%CI = [− 0.09,0.09], P < 0.0001, I2 = 78%). No significant difference was found in the postoperative BCVA between the two intervention methods (Fig. 3A).

Fig. 3
figure 3

Meta-analysis on Postoperative Visual Acuity. A Comparison of sutureless SF-IOL and suture SF-IOL with the best corrected visual acuity. B Comparison of sutureless SF-IOL and suture SF-IOL with the corrected distance visual acuity. C Comparison of sutureless SF-IOL and suture SF-IOL with the uncorrected visual acuity. D Comparison of sutureless SF-IOL and suture SF-IOL with the postoperative visual acuity change

CDVA

The CDVA after sutureless SF-IOL and suture SF-IOL were compared (WMD =  − 0.01, 95% CI = [− 0.21,0.20], P = 0.02, I2 = 82%), without significant difference between the two groups (Fig. 3B).

UCVA

The UCVA after sutureless SF-IOL and suture SF-IOL were compared (WMD = 0.01, 95% CI = [− 0.19, 0.22], P = 0.12, I2 = 58%). No significant statistical difference was found after comparison (Fig. 3C).

Postoperative visual acuity change

The postoperative visual acuity changes after sutureless SF-IOL and suture SF-IOL were compared (WMD =  − 0.14, 95% CI = [− 0.54, 0.26], P = 0.66, I2 = 0%), without statistical difference between the two (Fig. 3D).

Operation time

The operation times of sutureless SF-IOL and suture SF-IOL were compared (WMD =  − 29.39, 95% CI = [− 31.18, − 27.60], P = 0.34, I2 = 7%). The difference between the two was statistically significant, and the time required for sutureless SF-IOL was shorter (Fig. 4A).

Fig. 4
figure 4

Meta-analysis on operation time and intraocular lens inclination. A Comparison of sutureless SF-IOL and suture SF-IOL with the operation time. B Comparison of sutureless SF-IOL and suture SF-IOL with the horizontal inclination. C Comparison of sutureless SF-IOL and suture SF-IOL with the Vertical inclination

Intraocular Lens Inclination (horizontal and vertical)

The horizontal and vertical inclinations of intraocular lens after sutureless SF-IOL and suture SF-IOL were compared. (WMD =  − 0.27, 95% CI = [− 0.74, 0.19], P = 0.97, I2 = 0%; WMD =  − 0.27, 95% CI = [− 0.79, 0.25], P = 0.52, I2 = 0%). No significant difference was observed in the IOL inclination between the two interventions (Fig. 4B and C).

Absolute postoperative spherical equivalent

The absolute postoperative spherical equivalent of sutureless SF-IOL and suture SF-IOL at the last follow-up was compared (WMD =  − 0.19, 95% CI = [− 0.40, 0.02], P = 0.01, I2 = 56%). No significant difference was observed between the two groups (Fig. 5A).

Fig. 5
figure 5

Meta-analysis on absolute postoperative spherical equivalent, astigmatism and refractive prediction error. A Comparison of sutureless SF-IOL and suture SF-IOL with the absolute postoperative spherical equivalent. B Comparison of sutureless SF-IOL and suture SF-IOL with the postoperative IOL-related astigmatism

Postoperative astigmatism

The postoperative IOL-related astigmatism between sutureless SF-IOL and suture SF-IOL during the last follow-up was compared (WMD =  − 0.42, 95% CI = [− 0.91, 0.06], P = 0.002, I2 = 80%). no significant difference was found between the two (Fig. 5B).

Postoperative complications

Iris clamping

The number of cases of iris clamping after sutureless SF-IOL and suture SF-IOL was compared (OR = 1.17, 95% CI = [0.45, 3.05], P = 0.38, I2 = 2%), and no significant difference was observed (Fig. 6A).

Fig. 6
figure 6

Meta-analysis on postoperative complications. A Comparison of sutureless SF-IOL and suture SF-IOL with the postoperative iris clamping. B Comparison of sutureless SF-IOL and suture SF-IOL with the incidence of postoperative dislocation / subluxation of intraocular lens. Meta-analysis on incidence of postoperative decreased intraocular pressure. D Comparison of sutureless SF-IOL and suture SF-IOL with the incidence of postoperative decreased intraocular pressure. F Comparison of sutureless SF-IOL and suture SF-IOL with the incidence of postoperative elevated intraocular pressure

Dislocation/subluxation of intraocular lens

The number of cases of intraocular lens dislocation/subluxation after sutureless SF-IOL and suture SF-IOL was compared (OR = 0.98, 95% CI = [0.34, 2.83], P = 0.15, I2 = 43%). No significant difference was observed between the two interventions (Fig. 6B).

Decreased intraocular pressure

The incidences of intraocular pressure decrease after sutureless SF-IOL and suture SF-IOL were compared (OR = 1.12, 95% CI = [0.17, 7.52], P = 0.04, I2 = 60%), and no significant difference was found between the two groups (Fig. 6C).

Elevated intraocular pressure

The incidences of elevated intraocular pressure after sutureless SF-IOL and suture SF-IOL were compared (OR = 0.76, 95% CI = [0.36, 1.60], P = 0.80, I2 = 0%), without significant difference between the two groups (Fig. 6D).

Research and analysis

In this paper, the funnel chart and sensitivity map were analyzed for the research with I2 ≥ 50% and the number of studies ≥ 5 after merger.

BCVA

A comparative study of sutureless SF-IOL and suture SF-IOL (Fig. 7A and B). The funnel chart analysis found that the distribution of the study was symmetrical, but two studies exceeded the CI.

Fig. 7
figure 7

Funnel chart analysis and sensitivity map analysis on the best corrected visual acuity. A funnel chart analysis on comparison of sutureless SF-IOL and suture SF-IOL with the best corrected visual acuity. B sensitivity map analysis on comparison of sutureless SF-IOL and suture SF-IOL with the best corrected visual acuity. C funnel chart analysis on comparison of sutureless SF-IOL and suture SF-IOL with the best corrected visual acuity. D sensitivity map analysis on comparison of sutureless SF-IOL and suture SF-IOL with the best corrected visual acuity. E funnel chart analysis on comparison of sutureless SF-IOL and suture SF-IOL with the postoperative IOL-related astigmatism. F sensitivity map analysis on comparison of sutureless SF-IOL and suture SF-IOL with postoperative IOL-related astigmatism. G funnel chart analysis on comparison of sutureless SF-IOL and suture SF-IOL with the postoperative intraocular pressure decreased. H sensitivity map analysis on comparison of sutureless SF-IOL and suture SF-IOL with postoperative intraocular pressure decreased

Absolute postoperative spherical equivalent

A comparative study of sutureless SF-IOL and suture SF-IOL (Fig. 7C and D). The funnel chart found that the distribution of the study was symmetrical, but one study exceeded the CI.

Postoperative IOL-related astigmatism

A comparative study of sutureless SF-IOL and suture SF-IOL (Fig. 7E and F). The funnel chart analysis found that the distribution of the study was symmetrical, and no research was beyond the CI.

Postoperative intraocular pressure decreased

A comparative study of sutureless SF-IOL and suture SF-IOL (Fig. 7G and H). The funnel chart analysis found that the distribution of the study was symmetrical, but one study exceeded the CI. The sensitivity map analysis also found that one study had a great effect on the analysis of the results.

Discussion

In this systematic review and meta-analysis, one Chinese literature and 13 English articles were selected, of which 15 studies were included.

Combined with the study, no significant difference was found in the postoperative visual acuity (BCVA, CDVA and UCVA) between sutureless SF-IOL and suture SF-IOL. Meanwhile, the operation time of sutureless SF-IOL is shorter than that of suture SF-IOL.

The intraocular lens inclination (horizontal and vertical), absolute postoperative spherical equivalent, and astigmatism after sutureless SF-IOL were compared with those after suture SF-IOL. The difference was not statistically significant.

For the study of postoperative complications, the common postoperative complications, such as dislocation/subluxation of intraocular lens, iris clamping, pupil deformation, elevated pressure and decreased intraocular pressure were analyzed. No statistical difference was found in these comparisons.

In addition, a funnel chart and sensitivity map analysis were performed for the comparative studies with I2 ≥ 50% and the number of studies ≥ 5 after the merger. In accordance with the results, the relevant literature was reviewed to analyze the causes of heterogeneity. The causes of heterogeneity are described in Table 5. According to the analysis of funnel chart and sensitivity map, the main sources of heterogeneity in BCVA after sutureless SF-IOL and suture SF-IOL were the studies of Daniel.et al.2021(2) [16] and Zhang.et al.2021 [21]. After the studies of Daniel.et al.2021(2) [16] and Zhang.et al.2021 [21] were excluded, the heterogeneity decreased (WMD =  − 0.01, 95% CI = [− 0.04, 0.03], p = 0.07, I2 = 49%; Fig. 8A), which also proved the present work’s idea. In the comparison of absolute postoperative spherical equivalent between sutureless SF-IOL and suture SF-IOL, the main source of heterogeneity was the study of Yodpong.et al. 2018 [22] and Jae.et al.2020 [20]. After the study of Yodpong.et al. 2018 [22] and Jae.et al.2020 [20] was excluded, the heterogeneity decreased (WMD =  − 0.30, 95% CI = [-0.51, -0.09], p = 0.15, I2 = 34%; Fig. 8B). A significant difference was found in the refractive values between sutureless SF-IOL and suture SF-IOL, and the refractive value was lower after sutureless SF-IOL. In the comparison of the postoperative IOL-related astigmatism between sutureless SF-IOL and suture SF-IOL, the main sources of heterogeneity were the studies of Kyu.et al.2021 [18] and Yodpong.et al.2018 [22]. After the above two studies were excluded, a decrease in heterogeneity was found (WMD =  − 0.67, 95% CI = [− 1.01, − 0.33], p = 0.57, I2 = 0%; Fig. 8C), and A significant difference was observed between the two interventions. In the comparison of intraocular pressure reduction after sutureless SF-IOL and suture SF-IOL, the main source of heterogeneity was the study of Yu. etal.2018 [23]. After the study of Yu.et al.2018 [23] was excluded, a decrease in heterogeneity was found (OR = 1.97, 95% CI = [0.66, 5.94], p = 0.24, I2 = 29%; Fig. 8D).

Table 5 Cause analysis of heterogeneity
Fig. 8
figure 8

Meta-analysis on best corrected visual acuity,absolute postoperative spherical equivalent, postoperative IOL-related astigmatism and postoperative intraocular pressure decreased after exclude some researches. A Comparison of sutureless SF-IOL and suture SF-IOL with the best corrected visual acuity. B Comparison of sutureless SF-IOL and suture SF-IOL with the absolute postoperative spherical equivalent. C Comparison of sutureless SF-IOL and suture SF-IOL with the postoperative IOL-related astigmatism. D Comparison of sutureless SF-IOL and suture SF-IOL with the postoperative intraocular pressure decreased

In addition, the types of sutureless SF-IOL were divided into Gabor, Agarwal, and Yamane techniques. A subgroup analysis of the three techniques was conducted to determine the sources of heterogeneity in some of the comparative studies. In accordance with the number of studies, the difference in BCVA between Gabor technique and suture SF-IOL was compared (WMD = 0.12, 95% CI = [− 0.13, 0.38], P = 0.41, I2 = 0%; Fig. 9A). Although no statistical difference was found between the two, the heterogeneity of the study was low. In addition, the difference in BCVA between Yamane technique and suture SF-IOL was compared (WMD = 0.08, 95% CI = [− 0.00, 0.17], P = 0.93, I2 = 0%; Fig. 9B). No statistical difference was observed between the two, and the heterogeneity of the study was low. Meanwhile, the difference in the absolute postoperative spherical equivalent between Gabor technique and suture SF-IOL was compared (WMD =  − 0.06, 95% CI = [− 0.61, 0.50], P = 0.11, I2 = 55%; Fig. 10A). No statistical difference was found between them, but the heterogeneity was high. After the study of Yodpong.et al. 2018 [22] was analyzed and excluded, the heterogeneity decreased (WMD =  − 0.19, 95% CI = [− 0.50, 0.12], p = 0.22, I2 = 34%; Fig. 10B), and the difference was not statistically significant. In accordance with the original analysis, the heterogeneity caused by the study of Yodpong.et al. (2018) [22] is due to unnecessary refractive errors caused by the forward movement of the optical part of the intraocular lens after the IOL haptic enters the scleral tunnel during IOL fixation. The difference in the absolute postoperative spherical equivalent between Yamane technique and suture SF-IOL was also compared (WMD =  − 0.24, 95% CI = [− 0.49, 0.01], P = 0.02, I2 = 62%; Fig. 10C). No statistical difference was observed between them, but the heterogeneity was high. The study of Jae.et al. (2020) [20] was analyzed and excluded to further study and analyze the effect of reducing heterogeneity. The heterogeneity of the study decreased, and a statistical difference was found between the two (WMD =  − 0.33, 95% CI = [− 0.51, − 0.15], P = 0.13, I2 = 42%; Fig. 10D), which proved that the absolute postoperative spherical equivalent after Yamane technique was lower than that after suture SF-IOL. In accordance with the original analysis, the reason for the heterogeneity in the study of Jae.et al. (2020) [20] is that the caliber of vitrectomy for Yamane technique was 25G and that of suture scleral IOL implantation was 23G.The difference in astigmatism between Gabor technique and suture SF-IOL was also compared (WMD =  − 0.02, 95% CI = [− 0.11, 0.07], P = 0.29, I2 = 21%; Fig. 10E), without statistical difference between them. Meanwhile, a statistically significant difference in astigmatism was found between Yamane and suture SF-IOL (WMD =  − 0.82, 95% CI = [− 1.09, − 0.55], P = 0.73, I2 = 0%; Fig. 10F), which proved that the astigmatism in Yamane technique was smaller than that in the suture group.

Fig. 9
figure 9

Meta-analysis on the best corrected visual acuity of subgroup techniques. A Comparison of Gabor technique and suture SF-IOL with the best corrected visual acuity. B Comparison of Yamane technique and suture SF-IOL with the best corrected visual acuity

Fig. 10
figure 10

Meta-analysis on the absolute postoperative spherical equivalent and the postoperative astigmatism of subgroup techniques. A Comparison of Gabor technique and suture SF-IOL with the absolute postoperative spherical equivalent. B Comparison of Gabor technique and suture SF-IOL with the absolute postoperative spherical equivalent after exclude research. C Comparison of Yamane technique and suture SF-IOL with the absolute postoperative spherical equivalent. D Comparison of Yamane technique and suture SF-IOL with the absolute postoperative spherical equivalent after exclude research. E Comparison of Gabor technique and suture SF-IOL with the postoperative astigmatism. F Comparison of Yamane technique and suture SF-IOL with the postoperative astigmatism

To sum up, according to the analysis of the research results, the postoperative IOL-related astigmatism and absolute postoperative spherical equivalent of sutureless SF-IOL were lower than that of suture SF-IOL, indicating that the degree of refractive error after sutureless SF-IOL was lower. Meanwhile, the operation time of sutureless SF-IOL was shorter than that of suture SF-IOL. The subgroup analysis showed that the absolute postoperative spherical equivalent and astigmatism values in Yamane technique were lower than those in suture SF-IOL, with statistical value. This finding also proved that Yamane’s technique is superior to Gabor’s technique. Therefore, through the above analysis and summary, we believe that, compared with suture SF-IOL, Sutureless SF-IOL has the advantages of shorter operation time, stable postoperative refractive state and the incidence of postoperative complications. Yamane technique is superior to suture SF-IOL and Gabor’s technique in subgroup analysis.

In 1997, Italian scholars Ricardo Maggi and Carlo Maggi [24] put forward the concept of sutureless SF-IOL for the first time in view of the possible postoperative complications caused by suture. They chose an intraocular lens with three long 8.5 mm rings (made of polytetrafluoroethylene), which were fixed to the sclera through a special needle at 2:00, 6:00, and 10:00. This surgical method uses conjunctiva and sclera to cover the intraocular lens loop to avoid exposure to the outside of the eye, thus reducing the incidence of intraocular infection after operation. In addition, when using this method, if intraocular lens displacement or deviation occurs during operation, it could be corrected by adjusting the length of the ring. This method provides a new fixation method and fixed site for suture-free scleral interlamellar intraocular lens implantation. German scholar Gabor proposed seamless intraocular lens implantation in the ciliary sulcus in 2007 [25]. This method uses a standard three-piece foldable intraocular lens. The scleral tunnel is made by a common No. 24 cannula needle at the distance from the limbal of 1.5–2.0 mm, and then the IOL loop is brought into the scleral tunnel by tweezers, and the IOL loop is buried in the sclera. This method is the first time that the concept of “sutureless and glueless” has been applied to the clinic. During the follow-up period, no serious complications were noted, and in the later follow-up, 96.8% of the 63 patients had stable IOL. The work of Gabor provides a practical basis for the follow-up research, but the operation of the intraocular lens loop into the scleral tunnel is more difficult and takes a long time because of the equipment. In 2008, Agarwal [26] proposed to make a scleral flap to fix the IOL loop, which makes it more convenient to fix the IOL loop. Compared with the method proposed by Gabor, Agarwal expands the operating space by changing the shape of the sclera incision to make the IOL loop easier to draw out from the eye. However, excessive sclerotomy may cause postoperative scleral thinning and softening, resulting in other serious complications, and the technique closes the scleral flap with fibrin glue, which may lead to postoperative prion-associated infection [12]. In 2014, Yamane of Yokohama City University in Japan introduced a new technique at the annual meeting of ophthalmology in the United States [27]. This technique uses two No. 27 needles to perform scleral lamellar anatomy. It combines the advantages of Gabor and Akira’s methods, not only reducing the size of scleral incision and the probability of incision leakage and low intraocular pressure but also simplifying the operation procedure and shortening the operation time. Although some defects, such as difficulty in intraoperative operation and unstable intraocular lens fixation after operation [28], could still be noted, this method has been popularized after the report. In view of the poor stability of postoperative IOL, Yamane [29] proposed to use two No. 30 cannula needles to make a scleral tunnel and increase the fixation of IOL by cauterizing the end of IOL loop. The scleral damage of the 30 G needle used in this operation is less than that of the Nos. 25 and 27 G needle, and the smaller the diameter of the cannula needle is, the higher the stability of the scleral tunnel. No cases of dislocation were identified during the follow-up period in this study. So far, sutureless SF-IOL has been rapidly promoted.

At present, sutureless SF-IOL has become the mainstream surgical scheme for the clinical treatment of aphakic eyes, because it does not require suture, adhesion, scleral cauterization, and other operations. As a result, the tissue injury is greatly reduced, the incidence of postoperative complications is reduced, and the postoperative recovery time is shortened [14]. According to the comparative analysis of the present study, this method has the advantages of shorter operation time, more stable refractive state, and lower incidence of complications than suture SF-IOL.

The topic of comparing various secondary IOL techniques is a difficult and controversial issue, as well-designed comparative studies are rare and challenging to conduct due to the variations in each technique and the learning curve for each operator. The postoperative outcomes especially the operation time and visual acuity may be greatly influenced by the experience of the surgeon. Meanwhile, the reason of aphakia may influence the postoperative outcomes. Surgically, traumatically or congenitally induced aphakia may be accompanied with glaucoma, macular oedema and other ocular dysplasia. However, we believe that by comparing one surgical method with other surgical methods to find out the shortcomings of this surgical method and constantly adjust it is a feasible way to improve the quality of medical care. Besides, the main limitation of this study is the retrospective nature of most studies. The location of the IOL is determined by the surgeon’s preference and the patient’s eye history, leading to differences in baseline characteristics, which may affect the results between groups. Standardization among studies is also lacking, resulting in inconsistencies in clinical indications, surgical techniques, surgeon experience, reported results and limited duration in several studies. Meanwhile, duration of follow up is very important. The visual acuity, refractive errors, inclination of intraocular lens, and the postoperative complications may change with time. Thus, the quality of the evidence of the results differs, and it may lead to inconsistencies and statistical heterogeneity. In addition, the sample size of the study is small, which leads to the low statistical ability of some analyses. Due to the limited number of studies, this paper could not fully compare the differences among Yamane, Gabor, and Agarwal’s techniques.

Conclusion

According to the analysis of forest map, sensitivity map and funnel map, we found that the operation time of sutureless SF-IOL was shorter than that of suture SF-IOL, there was statistical difference when we compared the IOL-related astigmatism and the absolute postoperative spherical equivalent after sutureless SF-IOL and suture SF-IOL. Yamane technique is superior to suture SF-IOL and Gabor’s technique in subgroup analysis. In summary, Sutureless SF-IOL has the advantages of stable refraction and short operation time. However, high-quality literature to compare these technologies is lacking. Some long-term follow-up longitudinal prospective studies are needed to confirm the findings.