Abstract
Background
Recent advances in migraine research have shown that the cerebral cortex serves a primary role in the pathogenesis of migraine. Since aberrant brain activity in migraine can be noninvasively detected with magnetoencephalography (MEG), The object of this study was to investigate the resting state cortical activity differences between migraineurs and controls and its related clinical characteristics.
Methods
Twenty-two subjects with an acute migraine and twenty-two age- and gender-matched controls were studied using MEG. MEG recordings were recorded 120 seconds during the headache attack. Analyze MEG signals from low (1–4 Hz) to high (200–1000 Hz)-frequency ranges.
Results
In comparison with the controls, brain activity in migraine subjects was significantly different from that of the controls both in two frequency ranges (55–90 Hz, p < 0.001) and (90–200 Hz, p < 0.004). But the power value showed no significantly differences between control and migraines in all frequency ranges (p > 0.05). All the clinical characteristics had no significant correlation with aberrant brain activity.
Conclusions
The results demonstrated that migraine subjects in resting state had significantly aberrant ictal brain activity that can be measured with neuromagnetic imaging techniques. The findings may facilitate the development of new therapeutic strategies in migraine treatment via alterations in cortical excitability with TMS and other medications in the future.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Background
Migraine is a common episodic neurological disorder with a complex pathophysiology that manifests as recurrent attacks of headache that are typically throbbing and unilateral and often severe, with associated features such as hypersensitivity to multiple stimuli, including visual (photophobia), auditory (phonophobia), and sensory (cutaneous allodynia) stimuli during migraine attacks [1-5].
Migraine was originally speculated to be a disease solely involving the cranial vascular structures [1,6]. Recent studies have found that abnormal cortical excitability, believed to be due to calcium channelopathy, appears to play an important role in predisposing to spontaneous, cortical spreading depression, which is suggested to be one basis for the pathophysiology of migraine with aura [7]. Abnormal activation in the contralateral visual cortex in migraine with aura has been observed using functional magnetic resonance imaging (fMRI) [8]. The nature and mechanisms of the primary brain dysfunction(s) leading to the onset of a migraine attack, susceptibility to cortical spreading depression, and episodic activation of the trigeminovascular pain pathway remain largely unknown and are major outstanding issues that need to be addressed to further understand the neurobiology of migraine [2].
Magnetoencephalography (MEG), a relatively new clinical neuroimaging modality, is well suited for the study of cortical dysfunction in migraine because it can noninvasively detect and localize neuromagnetic signals associated with functional brain activation [9,10]. MEG is considered to be superior to scalp-electroencephalography (EEG) because the skull, skin, and other tissues can distort electric signals while magnetic signals can pass through these tissues without significant distortion [11,12]. Previous MEG studies investigating migraine have typically focused on neuromagnetic waveforms in a low-frequency range, such as DC-MEG signals. It has been shown that neuromagnetic brain activity is significantly increased in patients with migraine. Other studies have documented the hyperexcitability of the occipital cortex to visual stimulation in patients with migraine using MEG [13-15]. Another series of recent studies involving patients having an acute migraine or an acute exacerbation of chronic migraine showed that there were significant delays in both auditory processing of information and in motor response to cues, compared with age- and gender-matched controls [16-20]. The excitability of cell membranes appears to be a fundamental factor in the brain’s susceptibility to migraine attack [21].
The aim of the present study was to quantify the spatial and spectral abnormalities in brain activity at a resting state with MEG and to assess its relationship with clinical characteristics. To address this aim, we analyzed MEG signals from low- to high-frequency ranges. To the best of our knowledge, the present study is the first to examine the neuromagnetic signatures of aberrant resting-state brain activity in patients with acute migraine during headache attacks. With a better understanding of the cerebral mechanisms of migraine, headache treatments targeting at cortical dysfunctions (for example, transcranial magnetic stimulation, which currently shows great promise) could be refined and their clinical usefulness can be significantly improved.
Methods
Subjects
Twenty-two subjects with acute migraine (all women; mean age 31.4 years; standard deviation 3.6 years; age range 20 to 40 years) were recruited from the Department of Neurology, Nanjing Brain Hospital Affiliated Nanjing Medical University. The participants were pre-screened by neurologists specialized in headache at the authors’ Headache Clinic at Nanjing Brain Hospital. If a participant met the criteria and was interested in the MEG study, a researcher would explain the research protocol and obtain written informed assent and consent forms from the participants. The Institutional Review Board at Nanjing Brain Hospital formally approved the research protocol, assent, and consent forms. Inclusion criteria were: 1) migraine with or without aura as defined in the International Classification of Headache Disorders, 2nd Edition [18,22]; and 2) no other neurological disorder. Controls were recruited to match the migraine subjects for age and gender (Table 1), and met the inclusion criteria of 1) healthy, without a history of neurological disorder, headache, or brain injury; and 2) age-appropriate hearing, vision, and hand movement. Exclusion criteria for all participants were: 1) presence of an implant, such as cochlear implant devices, a pacemaker, or neurostimulator; devices containing electrical circuitry, generating magnetic signals, or other metal devices that could produce visible magnetic noise in MEG data; and 2) noticeable anxiety (expressing worry about the tests with noticeable physical trembling or sweating) and/or inability to readily communicate with the personnel operating the MEG equipment; and 3) taking antiepileptic drugs in the previous 3 days [14,20].
MEG recording
The brain signals of each subject were recorded for 2 min. The MEG data were recorded using a CTF 275-Channel MEG system (VSM Medical Technology Company, Canada) that assessed the entire head in a magnetically shielded room in the MEG Center at Nanjing Brain Hospital. Before data acquisition commenced, all subjects were asked to remove all possible metals from their body. Subsequently, electromagnetic coils were attached to the nasion, left and right pre-auricular points of the subject. These three coils were subsequently activated at different frequencies to measure subjects’ head positions relative to the MEG sensors. During the MEG recordings, the subjects were required simply to keep still as much as possible, close their eyes and not to think of anything systematically. The subjects were also asked to lie still comfortably in a supine position and avoid swallowing or clenching their teeth during the entire procedure.
To ensure all the subjects were awake, we analyzed Alpha waves. Alpha (8 Hz to 12 Hz) waves are one type of brain waves and predominantly originate from the occipital lobe during wakeful relaxation with closed eyes. Alpha waves are reduced with open eyes, drowsiness and sleep. In our study, the main activity of 8 Hz to 12 Hz (α wave) neuromagnetic regions in all of the subjects and controls were located in the occipital lobe.
The sampling rate of the MEG recordings was 4000 Hz per channel. The subject’s head positions relative to the MEG sensors were measured using the three coils. The head positions were measured at the beginning and the end of procedures. If head movement during a recording was >5 mm, the set was considered to be “bad” and an additional trial was recorded. The MEG signals were acquired with noise cancelation of third-order gradients.
Magnetic Resonance Imaging (MRI) scan
MRI scanning was performed on all subjects using a 1.5 T scanner (Sigma, GE, USA). Three MRI marks were placed in locations corresponding to the locations of the three coils used in the MEG recordings to co-register the MRI and MEG data. The scan field of view was 240 mm, field of view phase was 100%, repetition time was 6600 ms, echo time was 93 ms, and slice thickness was 1.00 mm.
MEGData analysis
MEG waveforms were visually inspected for identifying magnetic noise and artifacts. Any MEG data with noticeable magnetic noise or artifact (>6 pT) were excluded from the analyses. MEG data without noise or artifact were considered to be “clean MEG data.” MEG signals in delta (1 Hz to 4 Hz), theta (4 Hz to 8 Hz), alpha (8 Hz to 12 Hz), beta (12 Hz to 30 Hz), low-gamma (30 Hz to 45 Hz), high-gamma (55 Hz to 90 Hz), ripple (90 Hz to 200 Hz), and high-frequency oscillations (HFOs) (200 Hz to 1,000 Hz) were analyzed. The selection of bandwidth for ripple and HFO frequency bands was mainly based on previous studies investigating high-frequency brain signals in epilepsy [23,24]. Neuromagnetic sources were localized with accumulated source imaging [25,26]. Accumulated source imaging was defined as the volumetric summation of source activity over a period of time, which was specifically developed and optimized to analyze ictal activity in migraine patients. The source localization algorithms of accumulated source imaging were based on recent reports on MEG source reconstruction [27]. Accumulated source imaging could localize correlated sources by using node-beam lead fields [25]. Since each node-beam lead field represented a form of “source-beamformer” or “sub-space solution”, accumulated source imaging had multiple source beamformer to separate correlated sources. The detailed mathematical algorithms and validations are described in a recently published article [25].
To provide an accurate description of brain activity, each voxel in source imaging had at least three parameters: (1) strength of source activity, (2) correlation coefficients between the magnetic signals detected by the MEG system and the magnetic signals generated by the sources, and (3) the statistical significance of the differences between the magnetic signals detected by MEG system and the magnetic signals generated by the sources. We quantified source location with X, Y and Z axes in a 3D coordinate system defined by three fiducial points in MEG. The measurements of neuromagnetic source strength were performed using MEG Processor, a software package implementing the new method of accumulated source imaging [25]. See in Figure 1.
Statistical analyses
The odds ratio of activity in brain areas among the migraine and control groups was analyzed with Fisher’s exact tests. Analysis of variance (ANOVA) analysis was applied to the power value difference between migraine subjects versus controls. The correlation between migraine clinical characteristics (age, headache history, duration, pain type, frequency, and menstruation) and MEG parameters (source location and magnetic source power) were analyzed using Spearman correlation coefficients. For multiple comparisons, a Bonferroni multiple comparisons correction was used. Significance was accepted at the level of p < 0.05 for a single test. If multiple testing were to be taken into account, the significance level for each of these tests was reduced from 0.05 to 0.025 (two parameters) or 0.016 (three parameters).
Results
Clinical characteristics
Of the 22 subjects, six (27.27%) had migraine with aura and 16 (72.73%) had migraine without aura. None of the subjects with migraine with aura experienced the aura during the MEG recording. The average age was 31.63 ± 3.61 years. The headaches of seven (31.81%) women were related to menstruation. Fourteen of the 22 subjects had bilateral headaches (63.64%). The clinical characteristics are presented in Table 2.
Source location
The accumulated magnetic source imaging (MSI) showed that the main activity of neuromagnetic region of resting state in all the eight frequency ranges (Table 3).
In 8 Hz to 12 Hz (α wave), the main activity of neuromagnetic regions in almost all of the subjects and controls were located in the occipital lobe. There were no significant difference between migraine subjects and controls (Figure 2).
In some frequency ranges (1 Hz to 4 Hz, 4 Hz to 8 Hz, 12 Hz to 30 Hz, 30 Hz to 45 Hz, 200 Hz to 1000 Hz), the main activities of the neuromagnetic region in subjects with migraine were not significantly different compared with controls. Most were located in the deep brain areas, such as the brainstem, thalamus, and cerebellum, and were not analyzed in detail.
In the frequency band of 55 Hz to 90 Hz, the MSI showed that the main neuromagnetic activity in the resting state exhibited some differences. Compared with the control, the main neuromagnetic activity in subjects with migraines was observed to be in a significantly different brain region in the 55 Hz to 90 Hz frequency range (p < 0.05; Table 1). In the majority of the controls (21 of 22) and some of the subjects with migraine (11 of 22), the main neuromagnetic activity was in the DBA. The main neuromagnetic activity was located in the lateral frontal cortex (LFC) in some of the subjects with migraine (11 of 22) and very few controls (one of 22) (Figure 3).
In the frequency band of 90 Hz to 200 Hz, the result was similar to 55 Hz to 90 Hz. Compared with controls, the main neuromagnetic activity in subjects with migraines was also observed to be in a significantly different brain region in the 90 Hz to 200 Hz frequency range. In most of the controls (21 of 22) and some of the subjects with migraine (13 of 22), the main neuromagnetic activity was in the DBA. In some of the subjects with migraine (nine of 22) and very few controls (one of 22), the main neuromagnetic activity was located in the LFC [p = 0.004 (<0.05)] (Figures 4 and 5).
In all frequency rages, the main neuromagnetic activity was compared between subjects with migraine with aura and those with migraine without aura. There was no significant difference between these two groups (p > 0.05).
Source strength
The distributions of source power can be displayed on the individual MRI images. There was no significant difference in resting-state main activity of the neuromagnetic source power between the groups with migraine compared with controls in all eight-frequency ranges (from 1 Hz to 4 Hz, to 200 Hz to 1000 Hz; p > 0.05). The source power was also compared between subjects with migraine with aura and subjects with migraine without aura. There was also no significant difference between these groups (p > 0.05) (Table 4).
Clinical characteristics correlation
Results of correlation analyses demonstrated that there were no significant correlations between clinical characteristics (age, headache history, duration, pain type, frequency) and source location (p > 0.05). There were also no significant correlations between source power and clinical characteristics (p > 0.05). Because all subjects were women, the relationships between menstruation and both source location and source power were also analyzed; however, no significant correlations were observed (p > 0.05).
Discussion
The present study investigated the differences in resting-state brain activity and its related clinical characteristics, both in source location and source level from low- (1 Hz to 4 Hz) to high- (200 Hz to 1000 Hz) frequency neuromagnetic signals using MEG between a group of patients with acute migraines and a group of control patients. The source location data revealed differences between the two groups in two frequency ranges: 55 Hz to 90 Hz, and 90 Hz to 200 Hz.
To analyze frequency-dependent changes, MEG signals were divided into eight ranges (1 Hz to 4 Hz, 4 Hz to 8 Hz, 8 Hz to 12 Hz, 12 Hz to 30 Hz, 30 Hz to 45 Hz, 55 Hz to 90 Hz, 90 Hz to 200 Hz, 200 Hz to 1000 Hz). MEG is sensitive to magnetic noise generated by power lines, which were tentatively avoided by analyzing signals in 30 Hz to 45 Hz and 55 Hz to 90 Hz because the power-line noise in China is 50 Hz. Accumulated source imaging is suitable for the study of resting-state brain activity. According to previous reports of functional mapping [16,28-30], if the signals were produced by noise, they should not be consistently localized to a brain area. Furthermore, similar to the conventional averaging for detecting time-locked brain activity in evoked potentials and accumulated spectrograms [24,31], accumulated source imaging detects spatial- and frequency-locked brain activity over a period of time. However, magnetic noise commonly occurs in random frequencies and locations, except power-line noise. To validate the method, we volumetrically localized alpha activity (8 Hz to 12 Hz) for all subjects. Promisingly, alpha activity was consistently localized to the occipital cortex in controls. The reliability of the new approach has been verified with functional mapping [22,32-36], intracranial electroencephalography data, and surgical outcomes [24,31,37], and we are confident that the results are reliable and reproducible.
Most previous studies investigating migraine using MEG have used stimulation, including visual, auditory and motor. This series of studies found many significant differences between subjects with acute migraine and control subjects. Even in the same patient, ictal and interictal measures are significantly different [14,17,18,20]. Previous MEG studies investigating resting-state migraine typically only analyze the waveform and amplitude, or focus on small frequency ranges. These studies have resulted in several observations, such as suppression of spontaneous cortical activity, long-duration field changes, and large-amplitude waves of several seconds’ duration [10]. In the present study, we used a relative new analytical method that enables more direct and accurate analyses. To our knowledge, the present study is the first MEG accumulated source imaging study to investigate resting-state migraine in such a large number of frequency bands in high-frequency ranges in addition to low-frequency ranges. The entire brain was analyzed and volumetric rendering technology was utilized, which enabled us to visualize the functional organization of intrinsic brain activity as volumetric source imaging. Compared with conventional analyses of brain waveforms, our new approach provides spatial, frequency, as well as volumetric descriptions of the abnormalities of brain activity in subjects with migraine compared with controls.
The results of the present study reveal that subjects with acute migraine have a high likelihood of neuromagnetic activity in LFC compared with controls in two frequency ranges. Lateral frontal cortex has a relevant role in modulating behavioral responses to aversive stimuli and may significantly influence pain experience [38]. Since migraine is associated with cortical hyperexcitability, resting-state abnormal activity may play a key role in the cascade of migraine attacks. Resting-state abnormal activity may also influence brain activity following other stimulation, including visual, auditory and motor. The activities during stimulation are all based on the resting state; it is possible that the aberrant resting-state brain activity can provide a better, direct explanation of the pathogenesis of migraine. This observation may be critical for developing spatially targeted treatments for migraine. For example, high-frequency repetitive transcranial magnetic stimulation increases and low-frequency repetitive transcranial magnetic stimulation decreases neural excitability of the stimulated cortex [39-41].
If MEG could reliably reveal the location and types of cortical dysfunction occurring during migraine attacks, all of the preventions and treatments targeted at cortical excitability [42-44] could be refined and optimized. Therefore, we consider the present study to lay an important foundation for the clinical management of migraine in the future.
Although our data showed differences in source location between migraine and control groups, the source power and related clinical characteristics were not significantly different. This is likely due to limited number of subject groups; only two groups were included (ictal migraine and controls), and it is more than likely that the two groups had individual variations. In future research, an interictal migraine group may be added. Comparing three groups may minimize individual differences. Another limitation of the current study is the number of the participants. This is a limitation common to many MEG studies of multi-frequency analysis if high-frequency brain activity is included, because the study of high-frequency brain activity requires a high sampling rate of MEG data, which produces an unusually high number of MEG data points. Consequently, considerable computing power and time are required to analyze these data points and establish the spatial and spectral characteristics for all frequency ranges for each subject. However, with the development of the computer technology, especially the graphics processing unit, the core unit of graphics card, can solve this problem with the advantages of parallel computing, high-speed floating-point performance and high memory bandwidth. In addition, some confounding factors, such as the use of clinical drugs, may affect the results. Therefore, further investigation is necessary.
Conclusions
The results of the present study have demonstrated female patients with migraine during a headache attack had a higher likelihood of neuromagnetic activation in cerebral cortex. The findings support the notion that migraine is associated with cortical hyperexcitability. The abnormal ictal resting state brain activity may play a key role in the cascade of migraine attacks. These findings may be useful for developing spatially targeted treatment (such as rTMS) for migraine treatment in the future.
References
Hershey AD, Kabbouche MA, Powers SW (2006) Chronic daily headaches in children. Curr Pain Headache Rep 10(5):370–376
Vecchia D, Pietrobon D (2012) Migraine: a disorder of brain excitatory-inhibitory balance? Trends Neurosci 35(8):507–520, doi:10.1016/j.tins.2012.04.007
Coppola G, Schoenen J (2012) Cortical excitability in chronic migraine. Curr Pain Headache Rep 16(1):93–100, doi;10.1007/s11916-011-0231-1
Manack AN, Buse DC, Lipton RB (2011) Chronic migraine: epidemiology and disease burden. Curr Pain Headache Rep 15(1):70–78, doi:10.1007/s11916-010-0157-z
Rapoport A (2011) New frontiers in headache therapy. Neurological Sci 32(Suppl 1):S105–S109, do:10.1007/s10072-011-0542-3
Hershey AD, Winner P, Kabbouche MA, Powers SW (2007) Headaches. Curr Opin Pediatr 19(6):663–669, doi:10.1097/MOP.0b013e3282f1a07f
Welch KM, Barkley GL, Tepley N, Ramadan NM (1993) Central neurogenic mechanisms of migraine. Neurology 43(6 Suppl 3):S21–S25
Hadjikhani N, Sanchez Del Rio M, Wu O, Schwartz D, Bakker D, Fischl B, Kwong KK, Cutrer FM, Rosen BR, Tootell RB, Sorensen AG, Moskowitz MA (2001) Mechanisms of migraine aura revealed by functional MRI in human visual cortex. Proc Natl Acad Sci U S A 98(8):4687–4692, doi:10.1073/pnas.071582498
Chen WT, Wang SJ, Fuh JL, Ko YC, Lee YC, Hamalainen MS, Lin YY (2012) Visual cortex excitability and plasticity associated with remission from chronic to episodic migraine. Cephalalgia 32(7):537–543, doi:10.1177/0333102412443337
Barkley GL, Tepley N, Nagel-Leiby S, Moran JE, Simkins RT, Welch KM (1990) Magnetoencephalographic studies of migraine. Headache 30(7):428–434
Barkley GL, Baumgartner C (2003) MEG and EEG in epilepsy. J Clin Neurophysiol 20(3):163–178
Wheless JW, Castillo E, Maggio V, Kim HL, Breier JI, Simos PG, Papanicolaou AC (2004) Magnetoencephalography (MEG) and magnetic source imaging (MSI). Neurologist 10(3):138–153
Bowyer SM, Aurora KS, Moran JE, Tepley N, Welch KM (2001) Magnetoencephalographic fields from patients with spontaneous and induced migraine aura. Ann Neurol 50(5):582–587
Bowyer SM, Mason KM, Moran JE, Tepley N, Mitsias PD (2005) Cortical hyperexcitability in migraine patients before and after sodium valproate treatment. J Clin Neurophysiol 22(1):65–67
Aurora SK, Cao Y, Bowyer SM, Welch KM (1999) The occipital cortex is hyperexcitable in migraine: experimental evidence. Headache 39(7):469–476
Guo X, Xiang J, Wang Y, O’Brien H, Kabbouche M, Horn P, Powers SW, Hershey AD (2012) Aberrant neuromagnetic activation in the motor cortex in children with acute migraine: a magnetoencephalography study. PLoS One 7(11), e50095, doi:10.1371/journal.pone.0050095
Xiang J, Degrauw X, Korman AM, Allen JR, O’Brien HL, Kabbouche MA, Powers SW, Hershey AD (2013) Neuromagnetic abnormality of motor cortical activation and phases of headache attacks in childhood migraine. PLoS One 8(12), e83669, doi:10.1371/journal.pone.0083669
Korostenskaja M, Pardos M, Kujala T, Rose DF, Brown D, Horn P, Wang Y, Fujiwara H, Xiang J, Kabbouche MA, Powers SW, Hershey AD (2011) Impaired auditory information processing during acute migraine: a magnetoencephalography study. Int J Neurosci 121(7):355–365, doi:10.3109/00207454.2011.560312
Wang X, Xiang J, Wang Y, Pardos M, Meng L, Huo X, Korostenskaja M, Powers SW, Kabbouche MA, Hershey AD (2010) Identification of abnormal neuromagnetic signatures in the motor cortex of adolescent migraine. Headache 50(6):1005–1016, doi:10.1111/j.1526-4610.2010.01674.x
Xiang J, Degrauw X, Korostenskaja M, Korman AM, O’Brien HL, Kabbouche MA, Powers SW, Hershey AD (2013) Altered cortical activation in adolescents with acute migraine: a magnetoencephalography study. J Pain 14(12):1553–1563, doi:10.1016/j.jpain.2013.04.009
Welch KM (2003) Contemporary concepts of migraine pathogenesis. Neurology 61(8 Suppl 4):S2–S8
Huo X, Xiang J, Wang Y, Kirtman EG, Kotecha R, Fujiwara H, Hemasilpin N, Rose DF, Degrauw T (2010) Gamma oscillations in the primary motor cortex studied with MEG. Brain Dev 32(8):619–624, doi:10.1016/j.braindev.2009.09.021
Miao A, Tang L, Xiang J, Guan Q, Ge H, Liu H, Wu T, Chen Q, Yang L, Lu X, Hu Z, Wang X (2014) Dynamic magnetic source imaging of absence seizure initialization and propagation: a magnetoencephalography study. Epilepsy Res 108(3):468–480, doi:10.1016/j.eplepsyres.2014.01.006
Xiang J, Wang Y, Chen Y, Liu Y, Kotecha R, Huo X, Rose DF, Fujiwara H, Hemasilpin N, Lee K, Mangano FT, Jones B, DeGrauw T (2010) Noninvasive localization of epileptogenic zones with ictal high-frequency neuromagnetic signals: Case report. J Neurosurg Pediatr 5(1):113–122
Xiang J, Luo Q, Kotecha R, Korman A, Zhang F, Luo H, Fujiwara H, Hemasilpin N, Rose DF (2014) Accumulated source imaging of brain activity with both low and high-frequency neuromagnetic signals. Front Neuroinformatics 8:57. doi:10.3389/fninf.2014.00057
Xiang J, Tenney JR, Korman AM, Leiken K, Rose DF, Harris E, Yuan W, Horn PS, Holland K, Loring DW, Glauser TA (2014) Quantification of Interictal Neuromagnetic Activity in Absence Epilepsy with Accumulated Source Imaging. Brain Topogr, doi:10.1007/s10548-014-0411-5
Brookes MJ, Stevenson CM, Barnes GR, Hillebrand A, Simpson MI, Francis ST, Morris PG (2007) Beamformer reconstruction of correlated sources using a modified source model. Neuroimage 34(4):1454–1465, doi:10.1016/j.neuroimage.2006.11.012
Ge HT, Liu HX, Xiang J, Miao AL, Tang L, Guan QS, Wu T, Chen QQ, Yang L, Wang XS (2014) Abnormal cortical activation in females with acute migraine: A magnetoencephalography study. Clin Neurophysiol, doi:10.1016/j.clinph.2014.03.033
Chen Y, Xiang J, Kirtman EG, Wang Y, Kotecha R, Liu Y (2010) Neuromagnetic biomarkers of visuocortical development in healthy children. Clin Neurophysiol 121(9):1555–1562, doi:10.1016/j.clinph.2010.03.029
Gummadavelli A, Wang Y, Guo X, Pardos M, Chu H, Liu Y, Horn P, Zhang F, Xiang J (2013) Spatiotemporal and frequency signatures of word recognition in the developing brain: A magnetoencephalographic study. Brain Res, doi:10.1016/j.brainres.2013.01.001
Xiang J, Liu Y, Wang Y, Kirtman EG, Kotecha R, Chen Y, Huo X, Fujiwara H, Hemasilpin N, Lee K, Mangano FT, Leach J, Jones B, DeGrauw T, Rose D (2009) Frequency and spatial characteristics of high-frequency neuromagnetic signals in childhood epilepsy. Epileptic Dis 11(2):113–125, doi:10.1684/epd.2009.0253
Kotecha R, Pardos M, Wang Y, Wu T, Horn P, Brown D, Rose D, deGrauw T, Xiang J (2009) Modeling the developmental patterns of auditory evoked magnetic fields in children. PLoS One 4(3), e4811, doi:10.1371/journal.pone.0004811
Liu Y, Xiang J, Wang Y, Vannest JJ, Byars AW, Rose DF (2008) Spatial and frequency differences of neuromagnetic activities in processing concrete and abstract words. Brain Topogr 20(3):123–129, doi:10.1007/s10548-007-0038-x
Xiang J, Holowka S, Sharma R, Hunjan A, Otsubo H, Chuang S (2003) Volumetric localization of somatosensory cortex in children using synthetic aperture magnetometry. Pediatr Radiol 33(5):321–327, doi:10.1007/s00247-003-0883-z
Xiang J, Wilson D, Otsubo H, Ishii R, Chuang S (2001) Neuromagnetic spectral distribution of implicit processing of words. Neuroreport 12(18):3923–3927
Xiang J, Xiao Z (2009) Spatiotemporal and frequency signatures of noun and verb processing: a wavelet-based beamformer study. J Clin Exp Neuropsychol 31(6):648–657, doi:10.1080/13803390802448651
Xiang J, Holowka S, Qiao H, Sun B, Xiao Z, Jiang Y, Wilson D, Chuang S (2004) Automatic localization of epileptic zones using magnetoencephalography. Neurol Clin Neurophysiol 2004:98
Lopez-Sola M, Pujol J, Hernandez-Ribas R, Harrison BJ, Ortiz H, Soriano-Mas C, Deus J, Menchon JM, Vallejo J, Cardoner N (2010) Dynamic assessment of the right lateral frontal cortex response to painful stimulation. Neuroimage 50(3):1177–1187, doi:10.1016/j.neuroimage.2010.01.031
Brigo F, Storti M, Nardone R, Fiaschi A, Bongiovanni LG, Tezzon F, Manganotti P (2012) Transcranial magnetic stimulation of visual cortex in migraine patients: a systematic review with meta-analysis. J Headache Pain 13(5):339–349, doi:10.1007/s10194-012-0445-6
Teepker M, Hotzel J, Timmesfeld N, Reis J, Mylius V, Haag A, Oertel WH, Rosenow F, Schepelmann K (2010) Low-frequency rTMS of the vertex in the prophylactic treatment of migraine. Cephalalgia 30(2):137–144, doi:10.1111/j.1468-2982.2009.01911.x
Minks E, Kopickova M, Marecek R, Streitova H, Bares M (2010) Transcranial magnetic stimulation of the cerebellum. Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia 154(2):133–139
Scherer P, Bauer H, Baum K (1997) Alternate finger tapping test in patients with migraine. Acta Neurol Scand 96(6):392–396
Young WB, Gangal KS, Aponte RJ, Kaiser RS (2007) Migraine with unilateral motor symptoms: a case–control study. J Neurol Neurosurg Psychiatry 78(6):600–604, doi:10.1136/jnnp.2006.100214
Maertens de Noordhout A, Pepin JL, Schoenen J, Delwaide PJ (1992) Percutaneous magnetic stimulation of the motor cortex in migraine. Electroencephalogr Clin Neurophysiol 85(2):110–115
Acknowledgements
The authors also gratefully acknowledge the support of Department of Neurology, Nanjing Brain Hospital Nanjing Medical University. This study was financed based on a National Natural Science Foundation of China grant. Grant number (81271440).
Author information
Authors and Affiliations
Corresponding author
Additional information
Competing interests
The authors declare that they have no competing interests.
Authors’ contributions
XW carried out the Conception and design, participated in the Analysis and Interpretation of data and drafted the manuscript. HL carried out the acquisition of data and analysis and Interpretation of data and drafting the manuscript. TW and LY and QC participated in the analysis and Interpretation of data. HG and AM and LT participated in the design of the study and performed the statistical analysis. JX conceived of the study, and participated in its design and coordination and helped to draft the manuscript. All authors read and approved the final manuscript.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made.
The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.
To view a copy of this licence, visit https://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Liu, H., Ge, H., Xiang, J. et al. Resting state brain activity in patients with migraine: a magnetoencephalography study. J Headache Pain 16, 42 (2015). https://doi.org/10.1186/s10194-015-0525-5
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s10194-015-0525-5