Background

Contagious Bovine Pleuropneumonia (CBPP) caused by Mycoplasma mycoides subsp. mycoides (previously further specified as Small Colony (SC) type) (Manso-Silván et al. [1]) is considered as the main plague of cattle in Africa since the eradication of rinderpest (Roeder [2]). In recent years, CBPP re-emerged from where it had persisted and has spread to areas from which it had previously been eradicated, thus stimulating new, large-scale efforts to contain or possibly eradicate epidemics (http://www.fao.org). The pathogen is considered highly contagious and often there is only a slow development of clinical signs. Current vaccines against CBPP confer only partial and short-lived protection and there is some concern regarding their biosafety (Mbulu et al. [3]; Thiaucourt et al. [4]; Wesonga et al. [5]). Hence, rapid and reliable diagnosis of CBPP combined with traditional control measures including reduction of animal movement and isolation or stamping-out of affected animals, remains the most efficient way to control the disease. Serological methods are generally used for determining the CBPP status at herd level (Amanfu et al. [6]; Bruderer et al. [7]; Le Goff and Thiaucourt [8]; Muuka et al. [9]; Schubert et al. [10]; Tardy et al. [11]). Bacterial isolation is still the reference method for detection of the pathogen. However, bacterial cultivation of mycoplasma species in general and subsequent identification is cumbersome due to the fastidious growth requirements of these bacteria.

During the last two decades, several conventional and real-time PCR methods (qPCR) for rapid diagnosis of CBPP and early outbreak warning have been developed (Bashirrudin et al. [12]; Fitzmaurice et al. [13]; Lorenzon et al. [14]; Miserez et al. [15]; Schnee et al. [16]; Vilei and Frey [17]). Although such methods are specific and sensitive they depend on a laboratory infrastructure with sophisticated equipment and highly trained personnel. Most PCR protocols for CBPP diagnosis rely on the samples being pre-enriched for mycoplasmas and/or require expensive and laborious extraction methods. Such methods are not generally available in the rural areas of Africa where CBPP is possibly endemic and rapid diagnosis of the disease is essential. Another issue is that transportation of infected samples over long distances drastically affects the viability of the bacteria rendering them unfit for culturing and/or resulting in spoilage of the nucleic acid. To address the need for an in-the-field diagnostic method for CBPP, an isothermal loop-mediated amplification (LAMP) has been developed (Notomi et al. [18]). This is based on autocycling DNA synthesis under isothermal conditions in the presence of a thermophilic strand-displacing DNA polymerase that contains the 5’ → 3’ polymerase activity but lacks 5’ → 3’ exonuclease activity (such as Bst or Bsm polymerase). The technique uses four specific primers recognizing six distinct regions on the DNA template (Notomi et al. [18]). The CBPP LAMP developed is fulfilling most of the criteria for an Affordable, Sensitive, Specific, User-friendly, Robust and rapid, Equipment free and Deliverable to the end user (ASSURED) diagnostic system (Mabey et al. [19]).

Methods

Mycoplasma strains and DNA extraction

In this study, 83 strains of mycoplasmas representing 17 different species or subspecies including 28 isolates of M. mycoides subsp. mycoides were used (Additional file 1: Table S1). Mycoplasmas were grown in a standard medium (Axcell Biotechnologies, St. Genis l’Argentière, France) at 37°C to a density of 108–109 colony-forming units (CFU) per ml or on solid mycoplasma agar medium (Axcell Biotechnologies). Handling of live M. mycoides subsp. mycoides was performed in a biological safety laboratory fulfilling the BL3 containment safety standards. Lysis of mycoplasmas with GES buffer (5 M guanidium thiocyanate, 100 mM EDTA, 0.5% N-lauroylsarcosine) and extraction of genomic DNA were performed as previously described (Pilo et al. [20]).

Clinical samples

To allow for the use of the LAMP for diagnosis in the field, the amplification should effectively work without the need to extract DNA. This was studied using clinical samples of pleural fluid and bronchial lavage. Sequential bronchial lavage fluids were collected from cattle during an earlier experimental infection trial (Miserez et al. [15]; ethical approval by Swiss Federal Ministry of Veterinary Affairs). In addition, simulated clinical samples consisting of M. mycoides subsp. mycoides suspension supplemented with blood or squeezed liver tissues were prepared. The samples from inoculated cattle from Cameroun were from a vaccination trial (ethically approval by the board of directors of LANAVET, Cameroun; 2010).

Sample preparation

Samples (1.5 μl) were added to 25 μl of LAMP buffer (66 mM Tris-HCl pH 8.8, 32 mM KCl, 32 mM (NH4)2SO4, 16 mM MgCl2, 0.3% (v/v) Tween 20) and heated for five minutes at 95°C (a process available in the reading device), followed by immediate chilling and pulse centrifugation to sediment precipitates. Chilling was necessary before addition to the LAMP master mix to avoid damaging the strand displacement polymerase.

LAMP primer design

The gene sequence encoding a putative pro-lipoprotein of M. mycoides subsp. mycoides, locus tag MSC_0500 (GenBank accession number: BX293980.2 from the type strain PG1; Westberg et al. [21]) was selected for primer design. Since the initial primer design with PrimerExplorer 3.0 (Eicken, Japan; http://www.primerexplorer.jp/elamp3.0.0/index.html) did not yield a performing primer set (high GC content), we first designed the outer primers Msc3.1-F3 and Msc3.1-B3 (Table 1) with Primer Express 2.0 (Life Technologies, Grand Island NY, USA) according to the heat map profile. These colder sequences were then applied to PrimerExplorer 3.0 for the design of the inner primers Msc3.1-FIP and Msc3.1-BIP (Table 1). The melting temperatures (Tm) of the resulting primer sequences were all in the range of 56°C. Primers were then tested for hairpin structures, extensible primer hybrids and specificity by NetPrimer (PREMIER Biosoft, USA; http://www.premierbiosoft.com/netprimer/index.html) and Primer-BLAST (http://www.ncbi.nlm.nih.gov/tools/primer-blast/).

Table 1 Nucleotide sequences of the CBPP LAMP primers used

LAMP reaction conditions

The total volume of the LAMP assays was 25 μl i.e. 15 μl of LAMP buffer including the sample and 10 μl of master mix for final concentrations of 460 mM trehalose (alternative enhancer), 0.4 mM dNTP, 1.25 μM of each of the inner primers (Msc3.1-FIP and Msc3.1-BIP) and 0.25 μM of each of the outer primers (Msc3.1-F3 and Msc3.1-B3). The reaction mix also contained 8 U Bsm polymerase (Fermentas Thermo Scientific, St. Leon-Rot, Germany) and 0.4 × EvaGreen® dye (20×; Biotinum Inc., Hayward, CA, USA). Standard reactions were run for 60 min at 58°C in an ESEQuant Tube Scanner TS95 (Qiagen, Hilden, Germany) recording fluorescence from DNA bound EvaGreen once per minute. The optimal reaction temperature was predetermined on a gradient real-time cycler (StepOnePlus™; Life Technologies, Grand Island NY, US).

Quality assurance

To allow for a quality assurance protocol, the standard procedure for real-time PCR, melting curve analysis (MCA) and an alternatively re-association curve analysis was tested on a real-time platform (Rotor-Gene Q, Qiagen, Hilden Germany). After the LAMP process, for MCA samples were heated from 65°C to 90°C in 1°C/min steps with consecutive measurement at each step. For re-association of melted DNA (amplicons), reactions were cooled down from 90°C to 65°C in the same fashion. The amplicon inherent Tm was assessed with Oligo Calc (http://www.basic.northwestern.edu/biotools/oligocalc.html) and POLAND (http://www.biophys.uni-duesseldorf.de/html/local/POLAND/poland.html).

LAMP result evaluation

LAMP is a continuous process, unlike PCR, with parallel amplification and strand separation. Thus, only a “quasi” exponential function can be expected in short time increments and only the measurement of fluorescence in intervals of 1 minute or longer presents a continuous sigmoidal curve. For this exercise, we chose 1 min increments to evaluate the curve and defined an increase of > 30 mV/minute as a significant increase (Additional file 1). This algorithm was implemented in the Tube Scanner software and has the following limiting factors: the baseline starts after the third measurement and ends after the seventh, whereas the mean of the mV values represents the baseline value (Bv). The curve is classified as positive if the increase of signal (slope) above the mean of the baseline is > 30 mV for a minimum of 3 measurements (Additional file 1). The absolute time-point of detection Td (quantification) is determined when the slope increase is > 30 mV for the first time at a tube scanner excitation intensity of 36%.

Results

Evaluation of analytical sensitivity and specificity

To evaluate the specificity of the CBPP LAMP reaction, templates of purified DNA samples corresponding to approximately 106 genome equivalents or suspensions of mycoplasmal cultures corresponding to approximately 106 cells from 28 different strains of M. mycoides subsp. mycoides and from 57 strains of 15 other related mycoplasma species or subspecies (Additional file 1: Table S1) were examined in the CBPP LAMP. The CBPP LAMP gave positive signals for all 28 strains of M. mycoides subsp. mycoides, but not for any of the other 57 mycoplasma species. The LAMP reactions for the negative control remained negative, even when the reactions extended to 90 minutes.

To assess the limit of detection, a series of 10 fold dilutions of a suspension culture of M. mycoides subsp. mycoides strain Afadé were used as template. As shown in Figure 1, the method detects 1000 cells per reaction at a Time of detection (Td) of 45 minutes, while the detection of 10 cells requires an extended analysis time of Td = 67 minutes.

Figure 1
figure 1

Sensitivity of the CBPP LAMP: Titration curve based on diluted culture samples of M. mycoides subsp. mycoides strain Afadé directly employed in the reaction.

Quality assurance

For pathogen diagnosis, a quality assurance protocol is necessary. We performed MCA, the standard for qPCR and compared the result with the Tm for our CBPP amplicon calculated using two methods (nearest neighbour and Poland algorithm, respectively; Breslauer et al. [22]; Steger [23]). Interestingly, the calculated Tm (74.9°C) did not correspond to the values measured (78.4 to 79.0°C, dependent on the sample origin) (Figure 2). The analysis of the inverse protocol, re-association curve analysis (RCA) gave values matching the calculated ones thus allowing a reliable QA for CBPP LAMP diagnosis.

Figure 2
figure 2

Melting curve and re-association curve analysis of M. mycoides subsp. mycoides type strain PG1; directly from broth culture. The pre-determined Tm (74.9°C) corresponds to the value achieved through re-association (74.6°C) of exo-thermally separated LAMP products.

Analysis of clinical samples

The assessment of the test performance for the crude samples gave for the spiked samples a Td of around 45 minutes (103Mmm/reaction). Pleural fluid samples from two cows, with bacteriologically confirmed CBPP taken at necropsy, resulted in Td values ranging between 20 and 35 minutes (Figure 3).

Figure 3
figure 3

Calibration of the CBPP LAMP. Upper panel: Fluorometric output of LAMP amplifications using non-processed pleural fluid samples from a CBPP infected cow. Lower panel: Titration of M. mycoides subsp. mycoides strain Afadé culture fluid at various concentrations.

LAMP analyses of bronchial lavage samples taken sequentially from in-contact animals (Miserez et al. [15]) gave very similar results to the highly sensitive nested PCR based on P72 gene encoding the lipoprotein LppA (Tables 2, 3), showing that the CBPP LAMP was suitable for both clinical samples from necropsy and from live animals. The AFADE 16 samples gave identical results. The LAMP was additionally positive 4 times and the n-PCR was positive once more. For the L2 strain, 27 samples corresponded and additionally 5 times only LAMP was positive.

Table 2 Detection of M. mycoides subsp . mycoides in bronchial lavage fluid of cattle that were experimentally infected by contact with animals that were directly infected 4 weeks before with M. mycoides subsp . mycoides a) strain Afadé [[15]] or b) strain L2 [[15]]
Table 3 Detection of M. mycoides subsp . mycoides in bronchial lavage fluid of cattle that were experimentally infected by contact with animals that were directly infected 4 weeks before with M. mycoides subsp . mycoides a) strain Afadé or b) strain L2 (Miserez et al., [[15]])

Samples collected from a challenge trial in Cameroun revealed that not only were pulmonary samples and pleural fluids suitable for Mmm detection by LAMP, but the serum also gave valid results (Table 4).

Table 4 Experimental samples from Cameroun tested for M. mycoides subsp. mycoides (Mmm) by different methods and LAMP; all samples were collected >45 days post intubation and showed specific pathology on post mortem PM except 8410

Discussion and conclusion

Sensitive, reliable and time-saving molecular diagnostic tests, vital for the successful control of CBPP, mostly rely on TaqMan®-based real-time PCR for the detection of the pathogen M. mycoides subsp. mycoides in extracted and often pre-cultured clinical samples (Gorton et al. [24]; Schnee et al. [16]; Vilei and Frey [17]). Whilst these are broadly accepted as the most specific and sensitive method and as reference tests in control and surveillance programs, they depend on an elaborate and expensive laboratory infrastructure; sophisticated equipment and personnel with advanced molecular diagnostic knowledge hence, are not applicable to field conditions where CBPP is endemic and where on-site diagnosis is vital to provide confirmation of disease. A new and highly efficient isothermal amplification protocol for the detection of CBPP was developed that offers the same advantages of specificity and sensitivity of the real-time PCR methodology, but does not need the sophisticated laboratory-based equipment and is thus applicable to field conditions. This was accomplished through the design of a specific LAMP primer set for an already optimized master mix. To make the test suitable for the field, the master and the primer mix were lyophilized and are thus thermostable for a longer period (>1 year) and when rehydrated for at least one week on the bench. Additionally, the ready mixes allow the test to be carried out in only two pipetting steps (sample dilution and master mix assembly) thus avoiding errors and reducing training needs of operators.

Because the sample preparation and the amplification steps are run in a battery-driven instrument, the test can easily be performed at any location. The continuous reading of the fluorescence during amplification allows a real-time analysis of the results by the introduction of a minimum absolute increase value for positivity thus avoiding background problems usually faced with threshold values. The interpretation of results simply consists of monitoring the fluorescence increase of more than 30 mV for a minimum of two consecutive readings, which corresponds to a positive sample. Furthermore, these evaluation parameters can be programmed and therefore only the results are displayed on the instrument.

A QA procedure was established corresponding to the published Tm prediction models (Steger [23]; Schütz and van Ahsen [25]; Kibbe [26]). Despite the wide application of melting curve analysis (MCA), the re-association analysis in our setup gives the advantage of a direct correspondence to the established prediction calculations (Breslauer et al. [22]; Steger [23]) and does not require integration of surrogate parameters such as enhancers or dye factors. To perform the re-association analysis, specific software for the tube scanner (ESEmelt) was developed together with the producer based on the Savitzky-Golay filter algorithm (Savitzky and Golay [27]). False positive results due to random amplification of non-specific target DNA or contamination were excluded through the re-association analysis carried directly after amplification step without opening the vessel.

The analytical sensitivity (titration) of our test was comparable to the diagnostic sensitivity (clinical samples) better than, the real-time PCR or nested PCR. As in real-time PCR, heat-inactivated samples, after amplification, are kept in the closed tubes to avoid cross-contamination and to facilitate further analysis in a laboratory.

Regarding the ASSURED parameters published by Mabey the test fulfils all criteria with the exception of freedom from instrumentation. We believe that for a quality assured field result quantitative parameters which can be transmitted instantly to a reference laboratory are important thus allowing an immediate response which might be rather expensive.

The developed CBPP LAMP is an ideal, simple, robust and precise method to diagnose M. mycoides subsp. mycoides in an outbreak situation or during regular slaughterhouse inspections in monitoring programs for CBPP prevalence assessment.