Background

All pregnant women in the UK are offered an ultrasound scan to screen for structural anomalies between 18 and 20 weeks of pregnancy as part of their routine antenatal care [1]. Some structural abnormalities detected at this examination may be associated with an increased risk of chromosomal abnormalities. The diagnostic test for confirming this requires analysis of fetal genetic material that may be obtained by invasive procedures such as chorionic villi sampling or an amniocentesis which carry a procedure-related miscarriage risk of at least 1% [2].

In addition to significant structural abnormalities, ultrasound imaging has led to the identification of more subtle markers such as echogenic bowel, mild cerebral ventriculomegaly, renal pelvicalyceal dilatation, nuchal thickening, cardiac echogenic foci (golf balls), choroid plexus cysts, and short femur. In this protocol paper we refer to these collectively as markers. Reports of the prevalence of markers detected on antenatal scans vary, with one review suggesting that the range of the overall prevalence of all markers was 0.6% to 4.3% [3]. Isolated cardiac echogenic foci have been reported in 0.5%-4.9% of scans [4, 5], choroid plexus cysts in 0.6% - 2.1% [6], mild pelvicalyceal dilatation in 0.3% - 4.5% [7, 8] and echogenic bowel in 0.2% – 1.4% [7, 9]. Some of this variation was attributed to heterogeneity in the populations that have been studied. Many studies were carried out in tertiary or specialist institutions that manage a large number of high-risk pregnancies, while in other studies there was a lack of information about the characteristics of the populations that were studied. Variation may also result from the use of different definitions of the markers.

The clinical significance of these markers is unclear [3]. For example, there have been reports that echogenic bowel may be associated with cystic fibrosis [9, 10] and adverse pregnancy outcomes such as intra-uterine growth restriction and stillbirths [11, 12], particularly in high-risk pregnancies. However, there is uncertainty about their significance in low-risk pregnancies (i.e. those who do not have risk factors for chromosomal abnormalities or other pregnancy complications). There is also uncertainty among healthcare professionals about the best practice in clinical management of pregnancies where these markers are identified at the fetal anomaly scan [13]. UK-wide data has suggested that there is variation between hospitals in their clinical management of markers and in the information and quality of care given to women [14, 15].

The reporting of ultrasound findings of uncertain significance can cause unresolved maternal anxiety [16] and exposure to the risks associated with invasive diagnostic tests, although new standards for the performance of amniocentesis and chorionic villus sampling in Wales give clear guidance on appropriate indications for these procedures [17]. For some of these markers, it is not known whether there are long-term adverse health outcomes in children [3]. Questions that remain unanswered include: whether cardiac echogenic foci are associated with future development of cardiac abnormalities in childhood; whether mild cerebral ventriculomegaly (defined as a ventricular atrial diameter at any gestation of 10 mm to 12 mm) is associated with neuro-developmental delay and poorer educational outcomes; or whether pelvicalyceal dilatation is associated with postnatal uropathies or recurrent urinary tract infections in childhood.

We designed a population-based study to investigate the prevalence of markers and their associations with adverse pregnancy outcomes and longer-term health and social outcomes in children. The study objectives are:

  1. 1.

    To estimate the prevalence of individual markers at the 18 to 20 week anomaly scan in an unselected population of pregnant women attending for routine antenatal care in Wales;

  2. 2.

    To assess inter- and intra-sonographer variability in the detection of markers;

  3. 3.

    To investigate associations between the presence of markers and adverse pregnancy outcomes (major congenital abnormality, stillbirth, pre-term birth and small for gestational age);

  4. 4.

    To establish a cohort of children that can be followed-up to investigate associations between specific markers and longer-term health outcomes.

Methods/Design

Research design and setting

This is a population-based cohort study embedded within the routine antenatal services offered to pregnant women by NHS Wales. The population of Wales is approximately 3 million people, of whom approximately 20% are women of reproductive age [18]. All pregnant women have access to NHS maternity care, with almost universal uptake. Minimum standards for maternity care (including guidance on performing ultrasound scans) are recommended by the National Institute for Health and Care Excellence (NICE) and include at least ten antenatal check-ups for women expecting their first baby [1]. Wales is in a unique position to carry out this study because of the way in which healthcare data are routinely collected and can be electronically record-linked. First, an electronic information system for radiological data storage and reporting (Radiology Information Service 2 or RadIS2) was recently implemented in Welsh hospitals. Second, there are ongoing high-quality population-based registers for child health, including measures of pregnancy outcome such as gestation and weight at birth, congenital anomalies, stillbirths, neonatal and infant deaths recorded for all babies born in Wales. All of these systems (including RadIS2) use NHS numbers which can be used to link mother and baby across these routinely collected child health datasets. This provided a unique opportunity to collect standardised information on markers in a cohort of pregnant women and link these data to pregnancy and child health outcomes in their babies.

Ethical approval

Ethical approval was given by the Multicentre Research Ethics Committee (MREC) for Wales (reference 08/MRE09/17).

Participants and recruitment

Inclusion and exclusion criteria

All pregnant women receiving antenatal care within six of seven Welsh Health Boards who had an 18 to 20 week ultrasound scan in Welsh NHS Trusts between July 2008 and March 2011 were eligible for inclusion. The seventh Board was excluded as some of their population received antenatal ultrasound scans from hospitals outside Wales that did not use the RadIS2 system. Women were excluded if they were unable to give written informed consent.

Sample size calculations

Given the number of births in each Health Board and the planned phased introduction schedule for RadIS2 (which varied across Health Boards), it was anticipated that approximately 39,000 pregnant women would be eligible for recruitment during the study period. Assuming that 75% of these women would agree to participate (29,000) and that complete ultrasound and outcome data would be available for 80% of pregnancies, the study would have a projected sample size of 23,000.

A broad range of estimates for the prevalence of markers has been reported in previous studies (Table 1). Using several values from within this range, we performed sample size calculations to estimate i) the precision with which we could measure marker prevalence, and ii) the risk ratios that could be detected when examining the association between a marker and an adverse pregnancy outcome with 80% power at a 5% significance level. Data from 23,000 pregnancies would allow the prevalence of individual markers to be estimated with the following precision: a marker with 0.50% prevalence to within 0.10%; a marker with 1.00% prevalence to within 0.13%; and a marker with 4.50% prevalence to within 0.27%. The following sample size calculations are based on 80% power and a 5% Type 1 error rate. With 23,000 pregnancies and a marker prevalence of 0.5%, the sample size would be adequate to detect a 7-fold increase in an adverse pregnancy outcome which had a baseline prevalence of 1%, or a 2.75-fold increase in an adverse pregnancy outcome with a prevalence of 5%. With a marker prevalence of 1%, the sample size would be adequate to detect a 5-fold increase in an adverse pregnancy outcome which had a prevalence of 1%, or a 2-fold increase in an adverse pregnancy outcome with a prevalence of 5%. With a marker prevalence of 4.50%, the sample size would be adequate to detect with a 2.3-fold increase in an adverse pregnancy outcome which had a prevalence of 1%, or a 1.5-fold increase in an adverse pregnancy outcome with a prevalence of 5%.

Table 1 Definition of markers included in the study

Recruitment

Figure 1 shows the flow chart for recruitment, data collection and data linkage. Recruitment of pregnant women to the study started in July 2008 and ended in March 2011, with a phased roll-out to match the planned phased roll out of RadIS2 across Wales. A study information leaflet was included in the antenatal screening information pack given to pregnant women as early as possible in the pregnancy (at approximately eight to ten weeks of gestation). Women were given verbal information about the study and the opportunity to ask questions and obtain clarification about participation during their first antenatal visit with a healthcare professional (usually conducted by a community midwife between eight and twelve weeks of pregnancy). At this appointment, consent was obtained to:

Figure 1
figure 1

Flow chart of recruitment, data collection and data linkage.

  1. 1.

    Record the presence of markers;

  2. 2.

    Obtain antenatal Down’s syndrome screening results and cytogenetic results (if undertaken);

  3. 3.

    Use NHS numbers of the mother and her baby to link ultrasound data with data on pregnancy and health outcomes from the National Community Child Health Database (NCCHD), All Wales Perinatal Survey (AWPS), Congenital Anomaly Register and Information Service (CARIS), and newborn bloodspot tests; and,

  4. 4.

    Make future contact to obtain follow-up data on their baby.

Study stickers were placed on the front of the antenatal maternity hand-held notes of all women who had consented to participate to aid in the identification of these women at future contacts with health professionals. Stickers were also placed on the request card for the 18 to 20 week ultrasound scan in some sites. The consent form and the patient information leaflet are shown in Additional file 1 and Additional file 2.

Baseline data collection

The specific data items collected and the sources of data are shown in Table 2. A self-administered questionnaire following recruitment was used to collect baseline data on socio-demographics, smoking and alcohol use, and obstetric history. The postcode was used to assign women into a deprivation quintile using the Welsh Index of Multiple Deprivation [22]. In all Health Boards except one, women were given the questionnaire by a support worker, receptionist or sonographer to complete while waiting for their anomaly scan. Once completed, the questionnaires were placed in a box in the ultrasound department. Due to logistic reasons, one Health Board distributed and collected the questionnaires when the women attended their first hospital visit.

Table 2 Data items collected for the study and source

Data collection on markers

The definitions of the seven markers included in the study are shown in Table 1. The current practice in Wales is to routinely report four of these (echogenic bowel, mild to moderate ventriculomegaly, renal pelvicalyceal dilatation, and nuchal thickening). Data on the other three markers (choroid plexus cysts, echogenic cardiac foci, and short femur) were collected specifically for this study; these were not recorded on the clinical report and the woman was not informed of the finding given that these markers would not be reported in usual care. This was explained to the women as part of the consent process.

The presence or absence of markers was recorded in the RadIS2 system at the time of the 18 to 20 week scan. An additional reporting screen was added on to this system to enable rapid and accurate data collection for the study. Sonographers were requested to access this screen during the scans of all women who had consented to participate. RadIS2 implementation was delayed in three Health Boards. Alternative data reporting arrangements using paper forms were implemented at these locations.

Quality assurance of marker reporting

Before recruitment began, the sonographers in each Health Board (n = 140) attended an introductory session and were provided with a ‘Reference Guide for Sonographers’ which included the criteria for each marker as set out for this study. After this session, they were asked to complete a paper-based questionnaire to assess (i) compliance with the study protocol for the measurement of markers, (ii) agreement between sonographers and (iii) intra-sonographer agreement in reporting markers (by asking a sample of sonographers to complete the questionnaire a second time). The data generated were used to assess the level of compliance to the study protocol for the reporting of markers. These training and educational issues were discussed with superintendent sonographers in each Health Board who then provided additional training for their sonographers to address any gaps in knowledge identified.

An expert panel, consisting of radiologists and superintendent sonographers was established to review all anomaly scan images in which a marker had been reported (where images were available for review), to confirm the presence of the reported marker and identify any false positives. A review of all scan data by the expert panel to assess for false negative reports was not possible due to the substantial number of scans. However, the panel did review the scan images for all stillbirths, chromosomal abnormalities reported (Down’s and Edward’s syndrome) and cases of cystic fibrosis, to ascertain whether or not there were any markers visible in those scans that were not reported initially.

Definitions of adverse pregnancy outcomes

Major congenital abnormalities were as defined in Chapter XVII of the tenth revision of the International Statistical Classification of Diseases and Related Health Problems [23] and reported to the European Surveillance of Congenital Anomalies (EUROCAT), and were ascertained from cytogenetic results following amniocentesis or a report to CARIS at up to 1 year after the birth. Stillbirths are defined as the in-utero death of a baby after 24 completed weeks’ gestation. A preterm birth is defined as a birth before 37 weeks’ gestation, and small for gestational age is defined as below the 3rd centile for birth weight appropriate for gestational age, stratified by sex.

Data linkage

We used the NHS numbers of study participants to link the ultrasound scan data with routinely-collected data on pregnancy and health outcomes from NCCHD, AWPS, CARIS, All Wales Medical Genetics Service, Cytogenetics Department and the Down’s screening service (University Hospital of Wales, Department of Medical Biochemistry and Immunology). The extraction of outcome data and linkage to scan data using NHS numbers was co-ordinated by the NHS Wales Informatics Service (NWIS) (work completed during 2012 and 2013). All baseline questionnaires and ultrasound data that were collected on the paper forms were entered on a database by Screening Services Wales and uploaded to NWIS to be linked to the other study datasets.

Statistical analysis

We will calculate study recruitment rates for each hospital and Health Board. Socio-demographic characteristics (age at pregnancy, employment status, cigarette smoking, alcohol use and the Welsh Index of Multiple Deprivation) and pregnancy outcomes of women recruited to the study will be described. Characteristics of women recruited to the study will be compared with data routinely reported for pregnant women in Wales, to assess how representative the sample is of the general population.

We will calculate the reported prevalence of each marker as a proportion of the number of pregnant women with singleton pregnancies with scan data. We will also report the prevalence of validated markers (defined as markers confirmed by the expert panel). 95% confidence intervals [CI] for the validated markers will be estimated using Bayesian methods in Winbugs, to account for the two-stage sampling process (the availability of the images for review and the proportion of markers reviewed that were confirmed). We will describe the variation in prevalence of validated markers by NHS hospital and Health Board as well as by maternal socio-demographic and clinical characteristics. Unadjusted risk ratios with 95% CI will be calculated to estimate the risk of the adverse pregnancy outcomes in the presence of a validated marker compared with no marker, and in the presence of two or more markers compared with no marker. Odds ratios, adjusted for maternal age and deprivation score, will be calculated using logistic regression models if there is evidence of confounding by these variables. Data will be analysed using Stata version 13.0.

Discussion

This is a large prospective population-based study designed to estimate the prevalence of markers in a cohort of pregnant women and investigate associations with abnormal pregnancy outcomes. Quantifying these markers and assessing their significance is important as it will inform pregnancy management and parental counselling. The study addresses the criticism that many previous studies have not described their populations well and may not have included “all-risk” women [4]. This work has established a cohort of babies for longer-term follow-up to further explore associations between specific markers and child health outcomes, which are currently poorly understood [3].

The study takes advantage of an electronic information system for the collection of radiological data that was recently implemented in parts of Wales. This allows for the linkage of these data to high-quality population-based registers of pregnancy outcomes, congenital anomalies, and stillbirths. A major strength of this study is that we asked pregnant women at the time of recruitment for permission to access data that is routinely collected about the health of their baby to facilitate follow-up studies investigating health outcomes associated with markers detected at the 18-20 week anomaly scan. This provides some flexibility in the design of future follow-up studies, allowing us to utilise the wealth of health data that is routinely collected in a cost-effective way. For example, using record linkage to routinely collected healthcare datasets we could establish a future e-cohort study to explore whether babies with a renal marker detected during pregnancy have a higher risk of urinary tract infections or hospital admissions for renal disease during childhood, compared to babies without a marker. This information is vital for pregnant women, families and clinicians to facilitate the development of appropriate clinical guidelines and care pathways during pregnancy and after birth, including the appropriate use of medical interventions and treatment.