Skip to main content
Log in

Molecular electronic linear accelerometers. Preliminary test results

  • Published:
Gyroscopy and Navigation Aims and scope Submit manuscript

Abstract

The paper focuses on the accuracy characteristics of linear motion meters based on molecular electronic technology. Zero bias stability in terms of Allan variance and power spectral density is experimentally determined for the linear accelerometers. Harmonic distortions depending on the input amplitude are measured.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Larcam, C.W., Acoust. Soc. Am., 1965, vol. 37,no. 4, pp. 664.

    Article  Google Scholar 

  2. Vvedenie v molekuliarnuyu elektroniku (Introduction to Molecular Electronics), Ed., Lidorenko, N.S., (Moscow: Enegoatomizdat, 1984).

    Google Scholar 

  3. Kozlov, V.A. and Terentjev, D.A., Research of Frequency Characteristics of a Spatially Confined Electrochemical Cell under Convective Diffusion, Elektrokhimiya (Electrochemistry), 2002, vol. 38, no. 9, pp. 1104–1112.

    Google Scholar 

  4. Egorov, E.V., Kozlov, V.A., and Yashin, A.V., Phase-Frequency Characteristic of Transfer Function of a Spatially Confined Electrochemical Cell, Elektrokhimiya (Elektrochemistry), 2007, vol. 43, no. 12, pp. 1–7.

    Google Scholar 

  5. Agafonov, V.M. and Krishtop, V.G., Amplitude-Frequency Characteristic of a Molecular Electronic Transducer with a New Geometry, Mikrosistemnaya tekhnika (Microsystem Technology), 2004, no. 9, pp. 40–45.

  6. IEEE Std. 952-1997, Guide and Test for Single Axis Interferometric Fiber Optic Gyros, IEEE, 1997, p. 63.

  7. Stockwell, W., Bias Stability Measurement: Allan Variance, Crossbow Technology, 2004.

  8. Daily, M.R., Defense Manufacturing Conference, DMC’99, 1999.

  9. Kozlov, V.A. and Sakharov, K.A., Sobstvennye shumy molekulyarno-elektronnykh preobrazovatelei diffuzionnogo tipa (Self-Noise of Diffusion Molecular Electronic Transducers), in Fizicheskie osnovy zhidkostnykh i tverdotel’nykh izmeritel’nykh sistem i ustroistv obrabotki informatsii (Physical Foundations of Liquid and Solid-State Measurement Systems and Data Processing Devices), Moscow.: Izd. MFTI, 1994, pp. 43–49.

    Google Scholar 

  10. Newman, J.S. and Thomas-Alyea K.E., Electrochemical Systems, Wiley, 2004.

Download references

Author information

Authors and Affiliations

Authors

Additional information

Published in Russian in Giroskopiya i Navigatsiya, 2010, No. 1, pp. 72–80.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Agafonov, V.M., Egorov, E.V. & Zaitsev, D.L. Molecular electronic linear accelerometers. Preliminary test results. Gyroscopy Navig. 1, 246–251 (2010). https://doi.org/10.1134/S2075108710040024

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S2075108710040024

Keywords

Navigation