Abstract
The paper focuses on the accuracy characteristics of linear motion meters based on molecular electronic technology. Zero bias stability in terms of Allan variance and power spectral density is experimentally determined for the linear accelerometers. Harmonic distortions depending on the input amplitude are measured.
Similar content being viewed by others
References
Larcam, C.W., Acoust. Soc. Am., 1965, vol. 37,no. 4, pp. 664.
Vvedenie v molekuliarnuyu elektroniku (Introduction to Molecular Electronics), Ed., Lidorenko, N.S., (Moscow: Enegoatomizdat, 1984).
Kozlov, V.A. and Terentjev, D.A., Research of Frequency Characteristics of a Spatially Confined Electrochemical Cell under Convective Diffusion, Elektrokhimiya (Electrochemistry), 2002, vol. 38, no. 9, pp. 1104–1112.
Egorov, E.V., Kozlov, V.A., and Yashin, A.V., Phase-Frequency Characteristic of Transfer Function of a Spatially Confined Electrochemical Cell, Elektrokhimiya (Elektrochemistry), 2007, vol. 43, no. 12, pp. 1–7.
Agafonov, V.M. and Krishtop, V.G., Amplitude-Frequency Characteristic of a Molecular Electronic Transducer with a New Geometry, Mikrosistemnaya tekhnika (Microsystem Technology), 2004, no. 9, pp. 40–45.
IEEE Std. 952-1997, Guide and Test for Single Axis Interferometric Fiber Optic Gyros, IEEE, 1997, p. 63.
Stockwell, W., Bias Stability Measurement: Allan Variance, Crossbow Technology, 2004.
Daily, M.R., Defense Manufacturing Conference, DMC’99, 1999.
Kozlov, V.A. and Sakharov, K.A., Sobstvennye shumy molekulyarno-elektronnykh preobrazovatelei diffuzionnogo tipa (Self-Noise of Diffusion Molecular Electronic Transducers), in Fizicheskie osnovy zhidkostnykh i tverdotel’nykh izmeritel’nykh sistem i ustroistv obrabotki informatsii (Physical Foundations of Liquid and Solid-State Measurement Systems and Data Processing Devices), Moscow.: Izd. MFTI, 1994, pp. 43–49.
Newman, J.S. and Thomas-Alyea K.E., Electrochemical Systems, Wiley, 2004.
Author information
Authors and Affiliations
Additional information
Published in Russian in Giroskopiya i Navigatsiya, 2010, No. 1, pp. 72–80.
Rights and permissions
About this article
Cite this article
Agafonov, V.M., Egorov, E.V. & Zaitsev, D.L. Molecular electronic linear accelerometers. Preliminary test results. Gyroscopy Navig. 1, 246–251 (2010). https://doi.org/10.1134/S2075108710040024
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S2075108710040024