Abstract
The paper presents the performance studies of the scintillation detector prototype with SiPM readout using different types of the front-end electronics. The timing and position resolutions with LED have been obtained. These results can be applied for the proton and deuteron beams polarimetry at the Internal Target Station at Nuclotron.
Similar content being viewed by others
REFERENCES
V. P. Ladygin et al. (DSS Collab.), “Few-body studies at Nuclotron-JINR,” Few Body Syst. 55, 709 (2014).
M. Janek, V. P. Ladygin, Yu. V. Gurchin, S. M. Piyadin, A. A. Terekhin, A. Yu. Isupov, P. N. Batyuk, J.‑T. Karachuk, A. K. Kurilkin, P. K. Kurilkin, A. N. Livanov, G. Martinska, S. P. Merts, S. G. Reznikov, G. Tarjanyiova, A. A. Terekhin, and I. E. Vnukov, “Investigation of the dp Breakup and dp elastic reactions at intermediate energies at Nuclotron,” Few Body Syst. 58, 40 (2017).
A. Terekhin, “A study of the dp-elastic scattering at 2 GeV,” arXiv:1503.07968 [nucl-ex].
V. P. Ladygin et al. (SPD Collab.), “Possible studies at the first stage of the NICA collider operation with polarized and unpolarized proton and deuteron beams,” arXiv: 2102.08477 [hep-ph].
A. A. Terekhin (DSS Collab.), “Upgrade of the polarimeter at the internal target station at the Nuclotron,” J. Phys.: Conf. Ser 1435, 012051 (2020).
A. V. Tishevsky, Yu. V. Gurchin, A. Yu. Isupov, P. K. Kurilkin, V. P. Ladygin, S. G. Reznikov, Ya. T. Skhomenko, A. A. Terekhin, and A. N. Khrenov, “Study of the 16-channel scintillation detector prototype with silicon photomultiplier readout,” Phys. At. Nucl. 83, 1691 (2020).
A. V. Tishevsky, Yu. V. Gurchin, A. Yu. Isupov, A. N. Khrenov, M. Janek, P. K. Kurilkin, V. Kushpil, V. P. Ladygin, O. Mezhenska, S. G. Reznikov, and A. A. Terekhin, “Study of the 16-channel scintillation detector prototype with silicon photomultipliers readout,” AIP Conf. Proc. 2377, 030017 (2021).
A. V. Tishevskiy, Yu. V. Gurchin, A. Yu. Isupov, A. N. Khrenov, T. V. Kulevoy, V. P. Ladygin, P. A. Polozov, S. G. Reznikov, A. A. Terekhin, and I. S. Volkov, “Development of the scintillation detector prototypes with SiPM readout for SPD at NICA,” J. Phys.: Conf. Ser 1690, 012051 (2020).
I. A. Alekseev et al. (DANSS experiment), “DANSS: Detector of the reactor AntiNeutrino based on Solid Scintillator,” arXiv:1606.02896 [physics.ins-det].
Hamamatsu S12572-010P Datasheet. http://www.hamamatsu.com/jp/en/S12572-010P.html.
http://hvsys.ru/images/data/news/5_small_1368802948.pdf.
A. Yu. Isupov, “VME-based DAQ system for the deuteron spin structure setup at the Nuclotron internal target station,” EPJ Web Conf 204 10003 (2019).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
The authors declare that they have no conflicts of interest.
Rights and permissions
About this article
Cite this article
Tishevsky, A.V., Alekseev, I.G., Volkov, I.S. et al. Study of the Scintillation Detector Prototype for the Upgraded Polarimeter at the Internal Target Station at the Nuclotron. Phys. Part. Nuclei Lett. 20, 1165–1168 (2023). https://doi.org/10.1134/S1547477123050710
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S1547477123050710