Abstract
The time of extraction of negative ions from the ionization chamber of a static mass spectrometer has been measured as a value that significantly exceeds the time of their free exit from the chamber. It has been established that anomalously long ion extraction time is due to their adsorption on the ionization-chamber walls; as a result, their arrival at the analyzer tube is delayed. It has been shown that negative ions, which were initially generated as noninfinitely long-lived ones with respect to auto splitting off of an additional electron, are stabilized to everlasting ions due to adsorption, and the subsequent contribution from infinitely long-lived ions to the total ion flux reaching the recording system distorts the results of measuring the ion lifetime. It has been shown that some of the adsorbed ions are annihilated because of neutralization due to the additional electron tunneling to the surface. The probability of tunneling increases with an increase in temperature; thus, the temperature dependence of the ion lifetime is also distorted.
Similar content being viewed by others
References
E. Illenberger and B. M. Smirnov, Phys.-Usp. 41, 651 (1998)
V. G. Lukin, A. S. Vorob’ev, and G. S. Lomakin, Instrum. Exp. Tech. 52, 560 (2009).
M. Cannon, Y. Liu, L. Suess, F. B. Dunning, J. D. Steill, and R. N. Compton, J. Phys. Chem. 127, 064314 (2007).
P. P. Barzilovich, V. V. Zakharchenko, V. I. Zenkin, O. R. Savin, and V. F. Shkordoda, Prib. Sist. Upr., No. 1, 24 (1971).
O. R. Savin, V. I. Simonovskii, N. I. Starodub, et al., Prib. Sist. Upr., No. 10, 13 (1983).
V. I. Khvostenko, V. A. Mazunov, V. S. Fal’ko, et al., Khim. Fiz., No. 7, 915 (1982).
V. G. Lukin and G. S. Lomakin, Instrum. Exp. Tech. 53, 401 (2010).
Interface Device (Specification and Operation Manual) (Chernogolovka, 1989).
S. E. Trokhov, V. P. Shcherbinin, Yu. G. Seroklin, and Yu. S. Nekrasov, Prib. Tekh. Eksp., No. 3, 255 (1975).
V. I. Khvostenko, I. I. Furlei, V. A. Mazunov, and R. G. Kostyanovskii, Izv. Akad. Nauk SSSR, Ser. Khim., No. 3, 680 (1973).
V. G. Lukin, V. S. Fal’ko, and D. E. Vyazovkin, Avtometriya, No. 1, 111 (1992).
GDS-820C Digital Oscilloscope. Operation Manual (Moscow, 2007).
J. H. De Boer, The Dynamical Character of Adsorption (Clarendon Press, Oxford, 1968).
V. I. Khvostenko and G. A. Tolstikov, Russ. Chem. Rev. 45, 127 (1976).
O. G. Khvostenko and G. M. Tuimedov, Rapid Commun. Mass Spectrom. 20, 3699 (2006).
O. G. Khvostenko, G. M. Tuimedov, and U. M. Dzhemilev, Dokl. Phys. Chem. 414, 162 (2007).
O. G. Khvostenko, P. V. Shchukin, G. M. Tuimedov, M. V. Muftakhov, E. E. Tseplin, S. N. Tseplina, and V. A. Mazunov, Int. J. Mass Spectrom. 273, 69 (2008).
O. G. Khvostenko, V. G. Lukin, and E. E. Tseplin, Rapid Commun. Mass Spectrom. 26, 2535 (2012).
R. F. Tuktarov, R. V. Khatymov, P. V. Shchukin, M. V. Muftakhov, V. Yu. Markov, and O. A. Solomeshch, JETP Lett. 90, 515 (2009).
NIST/EPA Gas-Phase Infrared Database. https://www.nist.gov/srd/nist-standard-referencedatabase-35.
V. G. Lukin and G. M. Tuimedov, Instrum. Exp. Tech. 56, 565 (2013).
L. Sanche, J. Phys. B 23, 1597 (1990)
G. D. Waddill and L. L. Kesmodel, Phys. Rev. B 32, 2107 (1985).
Author information
Authors and Affiliations
Corresponding author
Additional information
Original Russian Text © V.G. Lukin, O.G. Khvostenko, G.M. Tuimedov, 2017, published in Zhurnal Tekhnicheskoi Fiziki, 2017, Vol. 87, No. 7, pp. 982–989.
Rights and permissions
About this article
Cite this article
Lukin, V.G., Khvostenko, O.G. & Tuimedov, G.M. Dispersion in the results of measuring the lifetime of negative ions due to their adsorption on ionization-chamber walls. Tech. Phys. 62, 998–1005 (2017). https://doi.org/10.1134/S1063784217070118
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S1063784217070118