Abstract—
A cryogenic source of polarized deuterium atoms is described. This source is used in the experiment on measuring the analyzing powers in the deuteron photodisintegration reaction at the VEPP-3 electron storage ring at the Budker Institute of Nuclear Physics. The efficiency has been measured for atomic transitions to a specified energy state in the medium field transition (MFT) unit, in the strong field transition (SFT) unit, and for joint operation of these units. A Lamb shift polarimeter was used in the measurements. The measured efficiency of the units is over 90%. The procedure for determining the background in the polarimeter is presented. The use of pumping in the ionizer chamber is expected to significantly reduce the background signal.
Similar content being viewed by others
REFERENCES
Vasilishin, B.I., Fix, A.I., Gauzshtein, V.V., Darwish, E.M., Kuzin, M.Ya, Levchuk, M.I., Loginov, A.Yu., Nikolenko, D.M., Rachek, I.A., Shestakov, Yu.V., Toporkov, D.K., Yurchenko, A.V., Zevakov, S.A., Bogomyagkov, A.V., Zhuravlev, A.N., et al., Phys. Rev. C, 2022, vol. 106, p. 024003. https://doi.org/10.1103/PhysRevC.106.024003
Isaeva, L.G., Lazarenko, B.A., Mishnev, S.I., Nikolenko, D.M., Popov, S.G., Rachek, I.A., Shestakov Yu.V., Toporkov, D.K., Vesnovsky, D.K., and Zevakov, S.A., Nucl. Instrum. Methods Phys. Res., Sect. A, 1998, vol. 411, p. 201. https://doi.org/10.1016/S0168-9002(98)00352-0
Plis, Yu.A. and Soroko, L.M., Nucl. Instrum. Methods, 1976, vol. 135, no. 3, p. 497. https://doi.org/10.1016/0029-554X(76)90064-1
Engels, R., Emmerich, R., Ley, J., Tenckhoff, G., Paetz gen. Schieck, H., Mikirtytchiants, M., Rathmann, F., Seyfarth, H., and Vassiliev, A., Rev. Sci. Instrum., 2003, vol. 74, no. 11, p. 4607. https://doi.org/10.1063/1.1619550
Dyug, M.V., Lazarenko, B.A., Mishnev, S.I., Nikolenko, D.M., Rachek, I.A., Shestakov, Yu.V., Sadykov, R.Sh., Toporkov, D.K., Zevakov, S.A., Osipov, A.N., and Stibunov, V.N., Nucl. Instrum. Methods Phys. Res., Sect. A, 2005, vol. 536, p. 344. https://doi.org/10.1016/j.nima.2004.08.096
Rachek, I.A., Barkov, L.M., Belostotsky, S.L., Dmitriev, V.F., Dyug, M.V., Gilman, R., Holt, R.J., Lazarenko, B.A., Mishnev, S.I., Nelyubin, V.V., Nikolenko, D.M., Osipov, A.V., Potterveld, D.H., Sadykov, R.Sh., Shestakov, Yu.V., Stibunov, V.N., Toporkov, D.K., de Vries, H., and Zevakov, S.A., Phys. Rev. Lett., 2007, vol. 98, p. 182303. https://doi.org/10.1103/PhysRevLett.98.182303
ACKNOWLEDGMENTS
We are grateful to Markus Büscher, Ralf Engels, and Lukas Huxold for their help in carrying out the work and the numerous discussions.
Funding
This work was supported by a grant of the Russian Science Foundation (no. 16-42-01009) jointly with a grant of the German Research Foundation (no. DFG BU 2227/1-1).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
The authors declare that they have no conflicts of interest.
Additional information
Translated by N. Goryacheva
Rights and permissions
About this article
Cite this article
Toporkov, D.K., Glukhovchenko, S.Y., Nikolenko, D.M. et al. Measurement of the Polarization of a Deuterium Atomic Beam Using a Lamb Shift Polarimeter. Instrum Exp Tech 66, 531–537 (2023). https://doi.org/10.1134/S0020441223030235
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S0020441223030235