Abstract
The Active spectroscopy plasma diagnostics (CXRS, charge eXchange recombination spectroscopy) and plans for its use in the ITER tokamak are described. A technique for the wavelength calibration of a multichannel polychromator spectrometer using a Fabry–Perot etalon is presented. This idea of the wavelength calibration of the spectrometer was originally used for the CXRS diagnostics in the JET tokamak. Using this technique, a high-resolution tri-band polychromator spectrometer, which was created for the CXRS diagnostics at the ITER facility, was calibrated. This polychromator spectrometer allows simultaneous measurements in three spectral ranges: 469–477, 529–538, and 650–661 nm. The obtained error of the calibration for various wavelengths was evaluated, which was on average 0.003 nm. The resulting calibration accuracy for different wavelengths is enough to meet the requirements for the CXRS diagnostics in the ITER tokamak with a margin.
Similar content being viewed by others
REFERENCES
Afrosimov, V.V., Gordeev, Yu.S., and Zinov’ev, A.N., Pis’ma Zh. Tekh. Fiz., 1977, vol. 3, p. 97.
Zinov’ev, A.N., Korotkov, A.A., Krzhizhanovskii, E.R., Afrosimov, V.V., and Gordeev, Yu.S., Zh. Eksp. Teor. Fiz., 1980, vol. 32, no. 9, p. 557.
Berezovskii, E.L., Berezovskaya, M.M., Izvozshchikov, A.B., and Krupin, V.A., Pis’ma Zh. Tekh. Fiz., 1982, vol. 8, p. 1382.
Fonck, R.J., Darrow, D.S., and Jaehnig, K.P., Phys. Rev. A, 1984, vol. 29, p. 6. https://doi.org/10.1103/PhysRevA.29.3288
Isler, R.C., Plasma Phys. Controlled Fusion, 1994, vol. 36, p. 171. https://doi.org/10.1088/0741-3335/36/2/001
Tugarinov, S.N., Beigman, I.L., Vainshtein, L.A., Dokuka, V.N., Krasil’nikov, A.V., Naumenko, N.N., Tolstikhina, I.Yu., and Khairutdinov, R.R., Plasma Phys. Rep., 2004, vol. 30, no. 2, p. 128.
Serov, S.V., Tugarinov, S.N., and Von Hellermann, M., Vopr. At. Nauki Tekh., Ser.: Termoyad. Sint., 2018, vol. 41, no. 2, p. 89. https://doi.org/10.21517/0202-3822-2018-41-2-89-94
Tugarinov, S.N., Serov, V.V., Belokopytov, A.A., Lukin, A.V., Sattarov, F.A., Shigapova, N.M., Kulakov, D.M., Usoltseva, M.A., Khabanov, F.O., Yartsev, V.P., and Naumenko, N.N., Instrum. Exp. Tech., 2016, vol. 59, no. 1, pp. 104–109. https://doi.org/10.1134/S0020441216010152
Donné, A.J.H., Costley, A.E., Barnsley, R., Bindslev, H., Boivin, R., Conway, G., Fisher, R., Giannella, R., Hartfuss, H., Von Hellermann, M.G., Hodgson, E., Ingesson, L.C., Itami, K., Johnson, D., Kawano, Y., et al., Nucl. Fusion, 2007, vol. 47, p. S343. https://doi.org/10.1088/0029-5515/47/6/S07
Zaidel’, A.N., Ostrovskaya, G.V., and Ostrovskii, Yu.I., Tekhnika i praktika spektroskopii (Technique and Practice of Spectroscopy), Moscow: Fizmatlit, 1972, pp. 163–164.
Delabie, E., Hawkes, N., Biewer, T.M., O’Mullane, M.G., and JET Contributors, Rev. Sci. Instrum., 2016, vol. 87, p. 11E525. https://doi.org/10.1063/1.4960306
Striganov, A.R. and Odintsova, G.A., Tablitsy spektral’nykh linii atomov i ionov. Spravochnik (Tables of Spectral Lines of Atoms and Ions. Handbook), Moscow: Energoizdat, 1982.
Author information
Authors and Affiliations
Corresponding author
Additional information
Translated by A. Seferov
Rights and permissions
About this article
Cite this article
Shabashov, A.Y., Serov, S.V., Tugarinov, S.N. et al. A Technique for Wavelength Calibration of a Multichannel Polychromator Spectrometer Using the Fabry–Perot Etalon. Instrum Exp Tech 62, 675–678 (2019). https://doi.org/10.1134/S0020441219040201
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S0020441219040201