Abstract
A high-sensitivity bolometer with a short time response to heating with external radiation has been developed. It is intended for measuring the integral parameters of soft X-ray radiation of liner plasma. The bolometer is adapted to the conditions of explosion experiments with an increased level of electromagnetic pickups at facilities that are based on magnetic-explosion generators with megaampere currents. The bolometer has a metal casing for improving the noise immunity of measurements. A 2-μm-thick nickel foil is used as the material for the resistive element of the working substance of the bolometer. The choice of the material and the geometrical dimensions of the bolometer working elements were analyzed. The ultimate thermal load on the bolometer was determined. A technique for calibrating the working elements using a pulse current was developed. The working capacity, good noise immunity, and a high sensitivity of the bolometer were demonstrated in experiments. The dynamic range in measurements of the surface energy density of X rays is 0.03–0.3 J/cm2.
Similar content being viewed by others
References
Deeney, C., Coverdale, C.A., Douglas, M.R., Struve, K.W., Spielman, R.B., Stygar, W.A., Peterson, D.L., Roderick, N.F., Haines, M.G., Beg, F.N., and Ruiz- Camacho, J., Phys. Plasmas, 1999, vol. 6, p. 3576.
Douglas, M.R., Deeney, C., Spielman, R.B., Coverdale, C.A., Roderick, N.F., and Haines, M.G., Phys. Plasmas, 2000, vol. 7, p. 2945.
Selemir, V.D., Demidov, V.A., Ivanovskii, A.V., Ermolovich, V.F., Kornilov, V.G., Chelpanov, V.I., Kazakov, S.A., Vlasov, Yu.V., and Orlov, A.P., Plasma Phys. Rep., 1999, vol. 25, no. 12, p. 1000.
Callen, D.E., Hubbel, J.H., and Kissel, L., Epdl 97: the evaluated photon data library 97 version, Report UCRL-5040, Lawrence Livermore National Laboratory, 1997, vol. 6, rev. 5.
Tablitsy fizicheskikh velichin. Spravochnik (Tables of Physical Quantities. A Handbook), Kikoin, I.M., Ed., Moscow: Atomizdat, 1976.
Gutorov, M.M., Osnovy svetotekhniki i istochniki sveta (Foundations of Lighting Technology and Light Sources), Moscow: Energoatomizdat, 1983.
Author information
Authors and Affiliations
Additional information
Original Russian Text © P.B. Repin, I.M. Markevtsev, S.Yu. Kornilov, 2014, published in Pribory i Tekhnika Eksperimenta, 2014, No. 2, pp. 97–102.
Rights and permissions
About this article
Cite this article
Repin, P.B., Markevtsev, I.M. & Kornilov, S.Y. A fast time-response bolometer for soft X-ray radiation energy measurements in a high-current Z-pinch. Instrum Exp Tech 57, 183–188 (2014). https://doi.org/10.1134/S0020441214020122
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S0020441214020122