The application of the arrangement with a secondary target for the X-ray fluorescent analysis of microimpurities in water solutions without sample destructions and preliminary sample preparations is considered. The limiting contrast values of fluorescence spectra are estimated, the limits of detecting impurities by the arrangement are theoretically calculated and experimentally measured (C min is smaller than 0.5 ppm). The range of chemical elements, which are efficiently excited by the secondary target, is determined by the C min criterion.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Afonin, V.P., Komyak, N.I., Nikolaev, V.P., and Plotnikov, R.I., Rentgenofluorestsentnyi analiz (X-ray Fluorescent Analysis), Novosibirsk: Nauka, 1991.

    Google Scholar 

  2. Anisovich, K.V., Perspektivy povysheniya chuvstvitel’nosti fluorestsentnogo rentgenospektral’nogo analiza. Apparatura i metody rentgenovskogo analiza (Prospects of Increasing the Sensitivity of Fluorescent X-ray Spectral Analysis. Equipment and Methods of X-ray Analysis), Leningrad: Mashinostroenie, 1980.

    Google Scholar 

  3. Ellis, A.T., Energy-Dispersive X-ray Fluorescence Analysis Using X-ray Tube Excitation, in Handbook of X-ray Spectrometry Revised and Expanded (Practical Spectroscopy), van Grieken, R. and Markowicz, A., Eds., CRC Press, 2001.

  4. Anisovich, K.V., Rentgenotekhnika: Spravochnik (X-ray Technique: A Handbook), Moscow: Mashinostroenie, 1980.

    Google Scholar 

  5. Injuk, J., Van Grieken, R., and Blank, A., Handbook of Practical X-Ray Fluorescence Analysis. Ch. 6: Specimen Preparation, Berlin: Springer, 2006.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Original Russian Text © I.F. Mikhailov, A.A. Baturin, A.I. Mikhailov, L.P. Fomina, 2012, published in Pribory i Tekhnika Eksperimenta, 2012, No. 4, pp. 80–84.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Mikhailov, I.F., Baturin, A.A., Mikhailov, A.I. et al. Detection limits of impurities in a light filler in an X-ray fluorescent arrangement with a secondary target. Instrum Exp Tech 55, 490–493 (2012). https://doi.org/10.1134/S002044121203013X

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S002044121203013X

Keywords

Navigation