A low-background scintillation setup situated in the Gran Sasso National Laboratory is described. The facility is composed of nine identical cells, each 2 L in volume. The 14C content of a PXE-based scintillator has been measured using this setup; the value obtained is R(14C/12C) = (12.6 ± 0.4) × 10−18. This result can be used for comprehensive investigation of possible 14C production channels in organic scintillators.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Libby, W.F., Anderson, E.C., and Arnold, J.R., Science, 1949, vol. 109, no. 2827, p. 227.

    Article  ADS  Google Scholar 

  2. Arpesella, C., Bellini, G., Benziger, J., et al., Phys. Lett. B, 2008, vol. 658, p. 101.

    Article  ADS  Google Scholar 

  3. Alimonti, G., Angloher, G., Arpesella, C., et al., Phys. Lett. B, 1998, vol. 422, p. 349.

    Article  ADS  Google Scholar 

  4. Back, H.O., Balata, M., de Bari, A., et al., Nucl. Instrum. Meth. Phys. Res. Sec. A: Acceler., Spectr., Detect. Assoc. Equip., 2008, vol. 585, nos. 1–2, pp. 48–60.

    Article  ADS  Google Scholar 

  5. Keefer, G., arXiv:1102.3786v1

  6. Buck, C., Barabanov, I., Besida, O., et al., Nucl. Phys. B (Proc. Suppl.), 2005, vol. 143, p. 487; Barabanov I., Besida O., Buck C., et al., Nucl. Phys. B (Proc. Suppl.), 2005, vol. 143, p. 559.

    Article  ADS  Google Scholar 

  7. Raghavan, R., Phys. Rev. Lett., 1976, vol. 37, p. 259.

    Article  ADS  Google Scholar 

  8. Motta, D., PhD Thesis, Heidelberg, 2004.

  9. Motta, D., Buck, C., Hartmann, F.X., et al., Nucl. Instrum. Meth. Phys. Res. Sec. A: Acceler., Spectr., Detect. Assoc. Equip., 2005, vol. 547, nos. 2–3, pp. 368–388.

    Article  ADS  Google Scholar 

  10. Neder, H., Kupfer-Probe fur LENS — “CuHD.” Auswertung der ersten Messperiode, 2002. Memo; http://www.mpi-hd.mpg.de

  11. Laubenstein, M., personal communication, 2003. http://www.lngs.infn.it

Download references

Author information

Authors and Affiliations

Authors

Additional information

Original Russian Text © C. Buck, O. Besida, C.M. Cattadori, F.X. Hartmann, Th. Lasserre, D. Motta, A. di Vacri, L. Pandola, S. Schoenert, U. Schwan, I.R. Barabanov, L.B. Bezrukov, N.A. Danilov, E.A. Yanovich, 2012, published in Pribory i Tekhnika Eksperimenta, 2012, No. 1, pp. 40–43.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Buck, C., Besida, O., Cattadori, C.M. et al. Measuring the 14C isotope concentration in a liquid organic scintillator at a small-volume setup. Instrum Exp Tech 55, 34–37 (2012). https://doi.org/10.1134/S0020441212010022

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S0020441212010022

Keywords

Navigation