Skip to main content
Log in

Time resolution of a 6-gap resistive plate chamber with strip readout

  • Nuclear Experimental Techniques
  • Published:
Instruments and Experimental Techniques Aims and scope Submit manuscript

Abstract

A 6-gap glass resistive plate chamber with a strip readout was tested on the beam of the U-70 accelerator at the Institute for High Energy Physics. A time resolution of ∼45 ps was attained at an efficiency of >98%. The position resolution along a strip was estimated to be ∼1 cm.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Williams, M.C.S., and ALICE Collaboration, Nucl. Phys. A., 1999, vol. 661, p. 707.

    Article  ADS  Google Scholar 

  2. Akindinov, A.V., Alici, A., Anselno, F., et al., Nucl. Instrum. Methods Phys. Res. A, 2004, vol. 532, p. 611.

    ADS  Google Scholar 

  3. Ammosov, V., Dumps, R., Dydak, F., et al., Nucl. Instrum. Methods Phys. Res. A, 2007, vol. 578, p. 119.

    Article  ADS  Google Scholar 

  4. González-Diaz, D., PhD Thesis, Universidad de Santiago de Compostela (Spain), 2006.

  5. Schuttauf, A., Hildenbrand, K.D., Ciobanu, M., et al., Nucl. Phys. B. Proc. Suppl., 2006, vol. 158, p. 52.

    Article  ADS  Google Scholar 

  6. STAR TOF Collaboration, Proposal for a Large Area Time of Flight System for STAR, May 24, 2004.

  7. PANDA Collaboration, Technical Progress Report: PANDA, Strong Interaction Study with Antiprotons, GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, 2005.

    Google Scholar 

  8. Kekelidze, V.D., Sissakian, A.N., and Sorin, A.S., Very High Multiplicity Physics Workshops, Singapore: World Sci., 2008, p. 22.

    Book  Google Scholar 

  9. Novosti i problemy fundamental’noi fiziki (News and Problems of Fundamental Physics), Protvino, 2008, no. 2, p. 31.

  10. Ammosov, V., Gapienko, V., Semak, A., et al., Preprint of Inst. for High Energy Phys., Protvino, 2002, no. 2002–10, p. 9.

  11. Petrovici, M., Herrmann, N., Hildenbrand, K.D., et al., Nucl. Instrum. Methods Phys. Res. A, 2002, vol. 487, p. 337.

    Article  ADS  Google Scholar 

  12. Sun, Y.J., Li, C., Shao, M., et al., Nucl. Instrum. Methods Phys. Res. A, 2008, vol. 593, p. 307.

    Article  ADS  Google Scholar 

  13. Abbrescia, M., Alici, A., An S., et. al., Nucl. Instrum. Methods Phys. Res. A, 2008, vol. 593, p. 263.

    Article  ADS  Google Scholar 

  14. Schuttauf, A., Nucl. Instrum. Methods Phys. Res. A, 2004, vol. 533, p. 65.

    Article  ADS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Original Russian Text © V.V. Ammosov, O.P. Gavrishchuk, V.A. Gapienko, V.G. Zaets, N.A. Kuz’min, Yu.M. Sviridov, A.A. Semak, S.Ya. Sychkov, E.A. Usenko, A.I. Yukaev, 2010, published in Pribory i Tekhnika Eksperimenta, 2010, No. 2, pp. 20–24.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ammosov, V.V., Gavrishchuk, O.P., Gapienko, V.A. et al. Time resolution of a 6-gap resistive plate chamber with strip readout. Instrum Exp Tech 53, 175–179 (2010). https://doi.org/10.1134/S0020441210020041

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S0020441210020041

Keywords

Navigation