Skip to main content
Log in

A nanosecond pulse amplitude-to-time interval converter

  • Electronics and Radio Engineering
  • Published:
Instruments and Experimental Techniques Aims and scope Submit manuscript

Abstract

A short (nanosecond) pulse amplitude-to-time interval converter features a 0.1- to 3.5-V input amplitude range with a 3- to 5-ns pulse duration. The conversion accuracy is about 0.5%, and the dead time is up to 10 μs. Differentiating feedback and temperature compensation are used to raise the conversion stability. The converter is intended for correcting errors of time synchronization units.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Grigor’ev, V.A., Kaplin, V.A., Loginov, V.A., et al., Nauch. sessiya MIFI-2005. III Konfer. nauchno-obtazovatel’nogo tsentra CRDF “Fundamental’nye issledovaniya materii v ekstremal’nykh sostoyaniyakh” (Scientific Session MIFI-2005: Fundamental Studies of Matter in Extreme States, Proc. IIIrd Conference of the Research and Education Center CRDF), Moscow: MIFI, 2005, p. 84.

    Google Scholar 

  2. Artyukh Yu., Bespal’ko, V., Lapushka, K., and Rybakov, A., in Proc. 12th International Workshop on Laser Ranging, Matera, Italy, 2000; http://www.edi.lv/HomePage/Publication/Artyukh_et_al_DRCEF.pdf.

  3. Denisov, S.P., Dzierba, A., Klimenko, A.K., et al., Prib. Tekh. Eksp., 2006, no. 4, p. 50 [Inst. Exp. Tech. (Engl. Transl.), vol. 49, no. 4, p. 494].

  4. Lubsandorzhiev, B.K., Kuzmichev, L.A., and Vasil’ev, R.V., Prib. Tekh. Eksp., 2003, no. 2, p. 42 [Inst. Exp. Tech. (Engl. Transl.), no. 2, p. 177].

  5. Kukush, V.D., Elekroradioizmereniya (Electrical Radio Measurements), Moscow: Radio i Svyaz’, 1985, pp. 137–141.

    Google Scholar 

  6. Artuykh, Yu., Bespal’ko, V., Lapushka, K., and Rybakov, A., Prib. Tekh. Eksp., 2008, no. 5, p. 160.

  7. Bespal’ko, V.A., Prib. Tekh. Eksp., 2001, no. 4, p. 167.

Download references

Author information

Authors and Affiliations

Authors

Additional information

Original Russian Text © V.A. Bespal’ko, 2009, published in Pribory i Tekhnika Eksperimenta, 2009, No. 2, pp. 57–60.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bespal’ko, V.A. A nanosecond pulse amplitude-to-time interval converter. Instrum Exp Tech 52, 204–206 (2009). https://doi.org/10.1134/S0020441209020110

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S0020441209020110

PACS numbers

Navigation