Abstract
A one-dimensional position-sensitive detector of thermal neutrons has been developed to equip high-efficiency neutron spectrometers at the ИБР-2 research reactor. The detector is based on a multiwire proportional chamber filled with a mixture of 3He + CF4 and has an active area of 200 × 80 mm and a spatial resolution of 2 mm. The detector has been used to good effect in the REFLEX and HRFD spectrometers of the ИБР-2 reactor, as well as in the diffraction facility of the ИВВ-2M research reactor (Zarechnyi, Russia).
Similar content being viewed by others
References
Fischer, J., Radeka, V., and Boie, R.A., Position-Sensitive Detection of Thermal Neutrons, New York: Academic, 1983.
Boulin, C.J., Kempf, R., Gabriel, A., and Koch, M.H.J., Nucl. Instrum. Methods Phys. Res., Sect. A, 1988, no. 269, p. 312.
Balagurov, A.M., Neutron News, 2005, vol. 16, p. 8.
Korneev, D.A., Bondarchuk, V.I., and Yaradaikin, S.P., Report of Joint Institute for Nuclear Research, Dubna, 2002, no. R3-2002-189.
Radeka, V., IEEE Trans. Nucl. Sci., 1974, vol. 21, p. 51.
Levchanovski, F.V., Gebauer, B., Litvinenko, E.I., et al., Nucl. Instrum. Methods Phys. Res., Sect. A, 2004, vol. 529, p. 413.
Levchanovsky, F.V., Litvinenko, E.I., Nikiforov, A.S., et al., Nucl. Instrum. Methods Phys. Res., Sect. A, 2006, vol. 569, p. 900.
Kirilov, A.S., Litvinenko, E.I., Astakhova, N.V., et al., Prib. Tekh. Eksp., 2004, no. 3, p. 65 [Instrum. Exp. Tech. (Engl. Transl.), no. 3, p. 334].
Aksenov, V.L., Jernenkov, K.N., Khaidukov, Yu.N., et al., Physica B, 2005, vol. 356, p. 9.
Author information
Authors and Affiliations
Additional information
Original Russian Text © A.V. Belushkin, A.A. Bogdzel’, V.V. Zhuravlev, S.A. Kutuzov, F.V. Levchanovskii, Li Yong Jae, E.I. Litvinenko, A.S. Nikiforov, Ts.Ts. Panteleev, V.I. Prikhod’ko, A.N. Chernikov, A.V. Churakov, V.N. Shvetsov, 2007, published in Pribory i Tekhnika Eksperimenta, 2007, No. 6, pp. 23–29.
Rights and permissions
About this article
Cite this article
Belushkin, A.V., Bogdzel’, A.A., Zhuravlev, V.V. et al. A one-dimensional position-sensitive detector for thermal neutrons. Instrum Exp Tech 50, 737–743 (2007). https://doi.org/10.1134/S0020441207060048