Skip to main content
Log in

X-ray spectral determination of gold in geological samples after its concentration by low-temperature fire assay

  • Analysis of Substances
  • Published:
Inorganic Materials Aims and scope

Abstract

The technology of gold extraction to lead from its mixture with the sample powder during lowtemperature alkaline fusion is developed. The optimal ratios of masses for the sample, lead, and alkali, as well as heating conditions, temperature, and fusion duration, are determined for satisfactory gold recovery. A low temperature of fusion makes it possible to lighten the structure of furnaces, to decrease energy consumption, and to shorten the duration of the entire cycle from the beginning of fusion until the next set of crucibles is loaded. Using the modular approach, a furnace can be assembled in a small area for the simultaneous fusion of a great number of samples. The results of determining gold by the X-ray fluorescence method obtained by using the proposed concentration technology satisfy the regulatory requirements with respect to accuracy.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Simakov, V.A., Isaev, I.E., and Kuznetsov, A.P., X-ray fluorescence determination of gold, platinum, and palladium in prills obtained by assay concentration of geological samples, Zavod. Lab., Diagn. Mater., 2013, vol. 79, no. 5, pp. 13–17.

    CAS  Google Scholar 

  2. Dolezal, J., Povondra, P., and Sulcek, Z., Decomposition Techniques in Inorganic Analysis, London: Iliffe, 1968.

    Google Scholar 

  3. Bock, R., A Handbook of Decomposition Methods in Analytical Chemistry, New York: Wiley, 1979.

    Google Scholar 

  4. Probootbiranie i analiz blagorodnykh metallov (Sampling and Analysis of Noble Metals), Baryshnikova, I.F., Ed., Moscow: Metallurgiya, 1978, pp. 116–138.

  5. OST (Industry Standard) 41-08-212–04. Admissible Error in Determining Chemical Composition of Mineral Raw Materials and Classification of Procedures of Laboratory Analysis with Respect to Accuracy of Results), Moscow: Vseross. Nauchno-Issled. Inst. Miner. Syr’ya, 2004.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to V. A. Simakov.

Additional information

Original Russian Text © V.A. Simakov, V.E. Isaev, 2015, published in Zavodskaya Laboratoriya, Diagnostika Materialov, 2015, Vol. 81, No. 10, pp. 11–14.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Simakov, V.A., Isaev, V.E. X-ray spectral determination of gold in geological samples after its concentration by low-temperature fire assay. Inorg Mater 52, 1440–1443 (2016). https://doi.org/10.1134/S0020168516140132

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S0020168516140132

Keywords

Navigation