Abstract
Background
Accurate diagnosis of coronary heart disease has the potential to contribute substantially to cost-effective delivery of health services. Recent work by Fleischmann et al (JAMA 1998;280:913-20) represents an effort to summarize the accuracy of exercise echocardiography and exercise single photon emission computed tomography (SPECT).
Methods and Results
A critique of the previous work was constructed, obtaining the 44 articles used. These articles were reviewed and summarized with established techniques for metaanalysis. The studies summarized by Fleischmann et al were found to be significantly heterogeneous (echocardiography and SPECT, both P < .001). In the SPECT cohort, combination of different radioisotopes and reading techniques, and inclusion of reports using experimental techniques, were sources of heterogeneity. In the echocardiography cohort, experimental techniques and an individual series were identified. When the sample was stratified for sources of heterogeneity, it was found that there was no significant difference in diagnostic accuracy between the echocardiography and SPECT techniques used in current clinical practice. Meta-regression with summary receiver operating characteristic curve techniques, after adjustment of the model for multicolinearity and outliers, revealed that there were no significant differences between SPECT as used in current clinical practice and echocardiography.
Conclusion
The report by Fleischmann et al contains serious flaws that limit its validity and generalizability.
Similar content being viewed by others
References
American Heart Association. Cardiovascular disease statistics. Available at: http://www.amhrt.org/catalog/Scientific_catpage70.html. Accessed 1999.
Fleischmann KE, Hunink MG, Kuntz K, Douglas P. Exercise echocardiography or exercise SPECT imaging? A meta-analysis of diagnostic test performance. JAMA 1998;280:913–20.
Petitti DB. Meta-analysis, decision analysis, and cost-effectiveness analysis; New York: Oxford Press; 1994.
Irwig L, Tosteson A, Gatsonis C, Lau J. Guidelines for meta-analyses evaluating diagnostic tests. Ann Intern Med 1994;120:667–76.
Egger M, Schneider M, Smith GD. Meta-analysis: spurious precision? Meta-analysis of observational studies. BMJ 1998;316:140–4.
Bailar JC III. Passive smoking coronary heart disease, and meta-analysis [editorial]. N Engl J Med 1999;340:958–9.
Peterson ED, Shaw LJ, Califf RM. Clincal guideline: part II; risk stratification after myocardial infarction. Ann Intern Med 1997;126:561–82.
Kuntz KM, Fleischmann KE, Hunink MGM, Douglas PS. Cost-effectiveness of diagnostic strategies for patients with chest pain. Ann Intern Med 1999;130:709–18.
Hunink MGM, Kuntz KM, Fleischmann KE, Brady TJ. noninvasive imaging for diagnosis of coronary artery disease: focusing the development of new diagnostic technology. Ann Intern Med 1999;131:673–80.
Kymes SM, Shaw LJ, Fletcher JF. Exercise cardiography or exercise SPECT imaging? A meta-analysis of diagnostic test performance [letter]. JAMA 1999;282:1622.
Hecht HS, DeBord L, Shaw R. Supine bicycle stress echocardiography versus tomographic thallium-201 exercise imaging for the detection of coronary artery disease. J Am Soc Echocardiogr 1993;6:177–185.
Hoffmann R, Lethen H, Kleinhans E, Weiss M, Flachskampf FA, Hanrath P. Comparative evaluation of bicycle and dobutamine stress echocardiography with perfusion scintigraphy and bicycle electrocardiogram for identification of coronary artery disease. Am J Cardiol 1993;72:555–9.
Marwick TH, D’Hondt AM, Mairesse GH. Comparative ability of dobutamine and exercise stress in inducing myocardial ischemia in active patients. Br Heart J 1994;72:31–8.
Pozzoli MMA, Fioretti PM, Salustri A, Reijs AE, Roelandt JR. Exercise echocardiography and technetium-99m MIBI single-photon emission computed tomography in the detection of coronary artery disease. Am J Cardiol 1991;67:350–5.
Quinones MA, Verani MS, Haichin RM, Mahmarian JJ, Suarez J, Zoghbi WA. Exercise echocardiography versus 201TI single-photon emission computed tomography in evaluation of coronary artery disease: analysis of 292 patients. Circulation 1992;85:1026–31.
Salustri A, Pozzoli MM, Hermans W, et al. Relationship between exercise echocardiography and perfusion SPECT in patients with singlevessel coronary artery disease. Am Heart J 1992;124:75–83.
Berman DS, Kiat H, Friedman JD. Separate acquisition rest thallium- 201/stress technetium-99m sestamibi dual-isotope myocardial perfusion single-photon emission computer tomography: a clinical validation study. J Am Coll Cardiol 1993;22:1455–64.
Chae SC, Heo J, Iskandrian AS, Wasserleben V, Cave V. Identification of extensive coronary artery disease in women by exercise singlephoton emission computed tomography (SPECT) thallium imaging. J Am Coll Cardiol 1993;21:1305–11.
Christian TF, Miller TD, Bailey KR, Gibbons RJ. Noninvasive identification of severe coronary artery disease using exercise tomographic thallium-201 imaging. Am J Cardiol 1992;70:14–20.
Fleming RM, Kirkeeide RL, Taegtmeyer H. Comparison of technetium- 99m teboroxime tomography with automated quantitative coronary arteriography and thallium-201 tomographic imaging. J Am Coll Cardiol 1991;17:1297–302.
Gupta NC, Esterbrooks DJ, Hilleman DE, Mohiuddin SM. Comparison of adenosine and exercise thallium-201 single-photon emission computed tomography (SPECT) myocardial perfusion imaging. J Am Coll Cardiol 1992;19:248–57.
Hambye AS, Vervaet A, Lieber S, Ranquin R. Diagnostic value and incremental contribution of bicycle exercise, first-pass radionuclide angiography, and 99mTc-labeled sestamibi single-photon emission computed tomography in the identification of coronary artery disease in patients without infarction. J Nucl Cardiol 1996;3:464–74.
Heiba SI, Hayat NJ, Salman HS. Technetium-99-MIBI myocardial SPECT: supine versus right lateral imaging and comparison with coronary arteriography. J Nucl Med 1997;38:1510–4.
Ho YL, Wu CC, Huang PJ. Dobutamine stress echocardiography compared with exercise thallium-201 single-photon emission computed tomography in detecting coronary artery disease-effect of exercise on level of accuracy. Cardiology 1997;88:379–85.
Kiat H, Van Train KF, Maddahi J. Development and prospective application of quantitative 2-day stress-rest Tc-99m methoxy isobutyl isonitrile SPECT for the diagnosis of coronary artery disease. Am Heart J 1990;120:1255–66.
Mahmarian JJ, Boyce TM, Goldberg RK, Cocanougher MK, Roberts R, Verani MS. Quantitative exercise thallium-201 single photon emission computed tomography for the enhanced diagnosis of ischemic heart disease. J Am Coll Cardiol 1990;15:318–29.
Minoves M, Garcia A, Magrina J, Pavia J, Herranz R, Setoain J. Evaluation of myocardial perfusion defects by means of “bulls eye” images. Clin Cardiol 1993;16:16–22.
Nguyen T, Heo J, Ogilby JD, Iskandrian AS. Single photon emission computed tomography with thallium-201 during adenosine-induced coronary hyperemia: correlation with coronary arteriography, exercise thallium imaging and two-dimensional echocardiography. J Am Coll Cardiol 1990;16:1375–83.
Oguzhan A, Kisacik HL, Ozdemir K. Comparison of exercise stress testing with dobutamine stress echocardiography and exercise technetium- 99m isonitrile single photon emission computerized tomography for diagnosis of coronary artery disease. Jpn Heart J 1997;38:333–44.
Palmas W, Friedman JD, Diamond GA, Silber H, Kiat H, Berman DS. Incremental value of simultaneous assessment of myocardial function and perfusion with technetium-99m sestamibi for prediction of extent of coronary artery disease. J Am Coll Cardiol 1995;25:1024–31.
Rubello D, Zanco P, Candelpergher G. Usefulness of 99mTc-MIBI stress myocardial SPECT bull’s-eye quantification in coronary artery disease. Q J Nucl Med 1995;39:111–5.
Solot G, Hermans J, Merlo P. Correlation of 99Tcm-sestamibi SPECT with coronary angiography in general hospital practice. Nucl Med Comm 1993;14:23–9.
Sylven C, Hagerman I, Ylen M, Nyquist O, Nowak J. Variance ECG detection of coronary artery disease: a comparison with exercise stress test and myocardial scintigraphy. Clin Cardiol 1994;17:132–40.
Taillefer R, DePuey EG, Udelson JE. Comparative diagnostic accuracy of Tl-201 and Tc-99m sestamibi SPECT imaging (perfusion and ECGgated SPECT) in detecting coronary artery disease in women. J Am Coll Cardiol 1997;29:69–77.
VanTrain KF, Garcia EV, Maddahi J. Multicenter trial validation for quantitative analysis of same-day rest-stress technetium-99m-sestamibi myocardial tomograms. J Nucl Med 1994;35:609–18.
VanTrain KF, Areeda J, Garcia EV. Quantitative same-day rest-stress technetium-99m-sestamibi SPECT: definition and validation of stress normal limits and criteria for abnormality. J Nucl Med 1993;34: 1494–02.
Van Train KF, Maddahi J, Berman DS. Quantitative analysis of tomographic stress thallium-201 myocardial scintigrams: a multicenter trial. J Nucl Med 1990;31:1168–79.
Beleslin BD, Ostojic M, Stepanovic J. Stress echocardiography in the detection of myocardial ischemia. Circulation 1994;90:1168–76.
Bjornstad K, Aakhus S, Hatle L. Comparison of digital dipyridamole stress echocardiography and upright bicycle stress echocardiography for identification of coronary artery stenosis. Cardiology 1995;86: 514–20.
Cohen JL, Ottenweller JE, George AK, Duvvuri S. Comparison of dobutamine and exercise echocardiography for detecting coronary artery disease. Am J Cardiol 1993;72:1226–31.
Crouse LJ, Harbrecht JJ, Vacek JL, Rosamond TL, Kramer PH. Exercise echocardiography as a screening test for coronary artery disease and correlation with coronary arteriography. Am J Cardiol 1991;67:1213–8.
Dagianti A, Penco M, Agati L. Stress echocardiography: comparison of exercise, dipyridamole and dobutamine in detecting and predicting the extent of coronary artery disease. J Am Coll Cardiol 1995;26:18–25.
Galanti G, Sciagra R, Comeglio M. Diagnostic accuracy of peak exercise echocardiography in coronary artery disease: comparison with thallium-201 myocardial scintigraphy. Am Heart J 1991;122:1609–16.
Jun T, Guizhen A, Xiaoming W, Jijun C, Jing X. Exercise echocardiography: feasibility and value for detection of coronary artery disease. Chin Med J 1996;109:381–4.
Luohtolati M, Saraste M, Hartiala J. Exercise echocardiography in the diagnosis of coronary artery disease. Ann Med 1996;28:73–7.
Marangelli V, Iliceto S, Piccinni G, De Martino G, Sorgente L, Rizzon P. Detection of coronary artery disease by digital stress echocardiography: comparison of exercise, transesophageal atrial pacing and dipyridamole echocardiography. J Am Coll Cardiol 1994;24:117–24.
Marwick TH, Nemec JJ, Pashkow FJ, Stewart WJ, Salcedo EE. Accuracy and limitations of exercise echocardiography in a routine clinical setting. J Am Coll Cardiol 1992;19:74–81.
Marwick TH, Anderson T, Williams MJ. Exercise echocardiography is an accurate and cost-efficient technique for detection of coronary artery disease in women. J Am Coll Cardiol 1995;26:335–41.
Marwick TH, Torelli J, Harjai K. Influence of left ventricular hypertrophy on detection of coronary artery disease using exercise echocardiography. J Am Coll Cardiol 1995;26:1180–6.
Roger VL, Pellikka PA, Oh JK, Bailey KR, Tajik AJ. Identification of multivessel coronary artery disease by exercise echocardiography. J Am Coll Cardiol 1994;24:109–14.
Roger VL, Pellikka PA, Bell MR. Sex and test verification bias: impact on the diagnostic value of exercise echocardiography. Circulation 1997;95:405–10.
Ryan T, Segar DS, Sawada SG. Detection of coronary artery disease with upright bicycle exercise echocardiography. J Am Soc Echocardiogr 1993;6:186–97.
Tawa CB, Baker WB, Kleiman NS. Comparison of adenosine echocardiography, with and without isometric handgrip, to exercise echocardiography in the detection of ischemia in patients with coronary artery disease. J Am Soc Echocardiogr 1996;9:33–43.
Williams MJ, Marwick TH, O’Gorman D, Foale RA. Comparison of exercise echocardiography with an exercise score to diagnose coronary artery disease in women. Am J Cardiol 1994;74:435–8.
Kent DL, Larson FB. Disease, level of impact, and quality of research methods: three dimensions of clinical efficacy assessment applied to magnetic resonance imaging. Invest Radiol 1992;27:245–54.
Fletcher J, Adams E, Flynn K, Papatheofanis F. Design of prospective clincal trials for assessment of PET. Clinical Positron Imaging 1998;1:201–11.
Midgette AS, Stukel TA, Littenberg B. A meta-analytic method for summarizing diagnostic test performance. Med Decis Making, 1993;13:253–7.
Lau J, Ioannidis JPA, Schmid CH. Quantitative Synthesis in Systematic Reviews. Annals of Internal Medicine November 1, 1997;127(9): 820–6.
Shaw LJ, Peterson ED, Kesler K, Hasselblad, Califf RM. A metaanalysis of predischarge risk stratification after acute myocardial infarction with stress electrocardiographic, myocardial perfusion, and ventricular function imaging. Am J Cardiol 1996;78:1327–37.
Thompson SG. Why sources of heterogeneity in meta-analysis should be investigated. BMJ 1994;309:1351–5.
Moses L, Shapiro D, Littenberg B. Combining independent studies of a diagnostic test into a summary roc curve: data-analystic approaches and some additional considerations. Stat Med 1993; 2:1293–1316.
de Vries S, Hunink M, Polak J. Summary receiver operating characteristic curves as a technique for meta-analysis of the diagnostic performance of duplex ultrasonography in peripheral arterial disease. Acad Radiol 1996;3:361–9.
Neter J, Kutner MH, Nachtsheim CJ, Wasserman W, eds. Applied linear regression models. 3rd ed. Chicago: Irwin; 1996.
Littenberg B, Moses L. Estimating diagnostic accuracy from multiple conflicting reports: a new meta-analytic method. Med Decis Making 1993;12:313–21.
Shapiro S. Meta-analysis/shmeta-analysis. Am J Epidemiol 1994;140: 771–8.
Hanley JA, McNeil BJ. The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology 1982;143: 29–36.
Russell MW, Huse DM, Drowns S, Hamel EC, Hartz SC. Derect medical costs of coronary artery disease in the United States. Am J Cardiol 1998;81:1110–5.
Patterson R, Eisner R, Horowitz S. Comparison of cost-effectiveness and utility of exercise ecg, single proton emission computed tomography, positron emission tomography, and coronary angiography for diagnosis of coronary artery disease. Circulation 1995;91:54–65.
Schelbert H, Maddahi J. Clinical cardiac PET: quo vadis? J Nucl Cardiol 1994;1:576–9.
DePuey EG, Rozanski A. Using gated technetium-99-m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact. J Nucl Med 1995;36:952–5.
Shaw LJ, Gillam L, Feinstein S. Use of an Intravenous contrast agent (optisontm) to enhance echocardiography: efficacy and cost implications. Am J Managed Care 1998;4:SP169-SP176.
Jacobs M. Review: exercise echo is a more specific and discriminitory test than exercise SPECT for coronary artery disease. ACP Journal Club 1999;130:45.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kymes, S.M., Bruns, D.E., Shaw, L.J. et al. Anatomy of a meta-analysis: A critical review of “Exercise echocardiography or exercise SPECT imaging? A meta-analysis of diagnostic test performance”. J Nucl Cardiol 7, 599–615 (2000). https://doi.org/10.1067/mnc.2000.109027