Abstract
We have investigated the activation characteristics of mining faults and the effect of grouting reinforcement under thick loose layer and thin bedrock of the working face and evaluate their impact on the safety of mining at similar working faces. Implementing the geological conditions of the 331 working face of the Yangcun Coal Mine (China) of the Yankuang Energy Group Corporation, we have analyzed mechanically the process of fault activation at first. Subsequently, we have obtained the mechanical criterion of fault slip and the expression of relative strength of the nearby rock mass. Using numerical software we have simulated and analyzed the damage characteristics of different bedrock thicknesses on overlying rocks and faults in the fluid–solid coupling mode. In addition, we have studied the controlling effect of grouting reinforcement on fault activation, which has been verified in the field. The main results of our study show that: 1. The mechanical properties of the rock mass near the fault interface have changed and they are related to the cohesive force of the interface; 2. The water inrush mode of the working face changes under different bedrock thickness, and the thinner the bedrock, the less easily the fault is destroyed 3. The slip of the high-level fault is reduced after the grouting of the fault, the propagation of the fracture zone at the fault is suppressed, the seepage of the aquifer water is prevented, and the safe recovery is realized. The results of our study provide a scientific basis for the secure mining across the fault of the 331 working face of Yangcun Coal Mine. Based on the results of our study the working face can be mined safely from now on and in the future.
Similar content being viewed by others
Introduction
Coal is the most important fossil energy source in China. According to the bulletin of the National Bureau of Statistics, China's raw coal production will reach 4.13 billion tons in 2021. In 2021, China's raw coal production and consumption will increase by 5.7% and 4.6%, respectively, and coal consumption will account for 56.0% of the total energy consumption. Coal mine water inrush seriously endanger the safety of workers and the progress of the mine production1,2,3. On July 5, 2012, a fault was induced in the Jialichong Xinjing Coal Mine in Leiyang City (Hunan Province, China) due to the change of the geological conditions during the excavation process, and the surrounding rock of the roadway collapsed, causing a water inrush accident and 16 workers were trapped underground. On March 11, 2013, the Heilongjiang Zhenxing Coal Mine (China) was mined for extra-thick coal seams due to top coal caving in the lower wall of the reverse fault, resulting in the development of water-conducting fracture zones which involved the upper coal seam and the fault zone. The process induced a major water accident at the working face and 18 worker lost their life. The economic loss was 22.81 million yuan. On October 25, 2019, blasting operation at the working face in the Xigu County Coal Mine of Xiangkuang, Changzhi City, Shanxi Province (China), caused the loosing of the fault fracture zone, which finally collapsed under the action of water pressure, leading to an old empty area and causing a large water disaster accident. Four miners lost their life and the economic loss was 9.68 million yuan. The examples of the mining accident demonstrate that coal seam mining may lead to fault activation with mine water inrush as one of the urgent problems that need conclusive solution.
To solve the problem of fault activation during mining operation, numerous studies have been conducted in recent years: Wankui et al.4 used the elasticity theory to analyze the relationship between the dip angle of normal faults and their activation, and concluded that normal faults with small dip angles are easier to activate. Used numerical simulation, Yaodong et al.5 studied the influence of different mining methods on fault activation and concluded that the impact of footwall mining on faults is more enhanced, and its activation risk is higher. Qingfeng et al.6 studied the activation water inrush mechanics model of the water-proof key layer containing water-proof faults, and proposed the water inrush conditions and water inrush principle of the fault mining activation under the combined action of mineral pressure and water pressure. Shucai et al.7 analyzed the filling medium. Based on the mechanical properties and seepage properties, they established the swallowtail catastrophe model of the sliding water inrush of the backfill structure. Aiwen et al.8,9,10,11,12 used similar material simulation experiments to study the stress change law of the fault under the influence of mining. Shao et al.13 established a multi-field coupled seepage characteristic evolution model to study the evolution process of water inrush inside the fault and the influence of water pressure, initial effective porosity, and initial permeability on water flow. Peisen et al.14,15 used numerical software to simulate the dip angle of the fault, the impact of drop, and broken zone width change on the stress and slip of the fault plane in the solid–liquid coupling mode. Using numerical simulations, Li et al.16,17,18,19,20,21 analyzed the coupled evolution process of stress field, displacement field and seepage field, and summarized the precursory information characteristics of fault activation.
The bond strength of the fault plane and the influence of the fault grouting reinforcement on the fault slip were not considered in the previous studies. The 331 working face of Yangcun Coal Mine of Yankuang Energy Group Co.Ltd. is part of the mining area under thin bedrock and thick loose aquifer. The normal fault of Quince Tree No. 2 in the working face crosses the working face obliquely from the upper left end of the incision. The working face must be mined across the fault, which is very risky. Therefore, we have developed a plan for grouting and strengthening of the fault prior to the mining. To reduce the probability of water gushing and sand inrush accidents caused by fault activation, we studied the failure characteristics of faults and the effect of grouting reinforcement under different bedrock thickness conditions based on the mechanism of fault activation mechanics and the analysis of the bonding force of the fault zone. Based on the degree of fault activation control we can evaluate the mining safety of the working face, providing a reliable scientific basis for the safe production of the working face.
Mechanical analysis of fault activation mechanism
After excavation of the coal seam, the fault is activated through the influence of mining. To study the mechanical behavior of the rock mass near the fault and the conditions for slipping, we simplified the actual fault as a rock-fault zone structure with a contact surface (see Fig. 1) mechanical analysis.
According to the Mohr–Coulomb criterion, the residual shear force of the contact surface slipping is obtained as:
with τe as the residual shear stress at the contact surface, τ1 as the shear stress on the contact surface, and cj as the bonding force of the contact surface.
According to the generalized Hooke's law and Moore's Coulomb strength theory, the axial ultimate strengths of the rock mass near the contact surface are obtained as:
in:
with Rc as the uniaxial compressive strength of the rock mass; fRF as the friction coefficient at the contact surface; and φ as the internal friction angle of the rock mass.
If the residual shear force τe is > 0, the structure body slides along the contact surface according to Eq. (1), and the greater the stress (σ1) of the fractured rock mass, the easier the structure body slides along the contact surface. In the peak area of supporting pressure, i.e., in front of the coal wall of the coal mining face, the fault activation is more likely to occur. Equations (2) and (3) indicate that, for fixed values of other parameters, the greater the bonding force of the contact surface, the greater the degree of strengthening of the fault zone, and the lower the strength required for the rock at the contact surface. On the contrary, the smaller the bonding force of the contact surface, the lower the degree of strengthening of the fault zone, and the greater the strength required for the rock at the contact surface, which is reflected in good coordination and consistency. This shows that if the fault zone at the peak area of supporting pressure in front of the coal wall of the coal mining face is not activated, it is necessary to increase the bonding force between the fault zone and the contact surface of the rock formation (which can be achieved by grouting) or to improve the strength of the rock formation. The peak area of supporting pressure in front of the coal wall of the underground coal mining face is bound to appear, and the seepage of water is very likely to occur in the near loose aquifer (even the weak aquifer). The water-bearing situation in the fault zone is also common. However, the previous analytical equation does not consider the influence of confined water and fluid–solid coupling. Moreover, it is difficult to accurately describe the activation characteristics of fault zones and the effect of grouting reinforcement of fault zones in the dynamic process of production for the three-dimensional underground space. Therefore, we use the cross-fault mining under the thin bedrock and thick loose layer of the 331 working face of the Yangcun Coal Mine of Yankuang Energy Group Corporation as a case study. Based on the mechanical analysis, the FLAC3D numerical simulation software is used to conduct various methods to model the slip failure of the fault. The results will improve the safety and feasibility of cross-fault mining under the thin bedrock and thick loose aquifer of the 331 working face.
Engineering background
Coal seam and roof and floor characteristics
The research area studied in our project is the designed mining area of the 331 working face of Yangcun Coal Mine. The length of the working face is 452–610 m, the width of the cut hole is about 182 m, the width of the stop line is about 100 m, and the area is about 89,309 m2 (Fig. 2). The buried depth of the 3 coal seam is 215.8 m, the dip angle of the coal seam is 1° to 6°, with an average of 4°, and the thickness of the coal seam is 7.75–9.20 m, with an average of 8.20 m. The bedrock thickness is 15.9–49.3 m. Most of the area 3 coal seams are less than 40 m away from the Quaternary loose layer aquifer. The Quince Tree No. 2 normal fault (with a fall of 6 m, an inclination of 50°, and width of 3 m) cross-cuts the 331 working face (Fig. 2), posing a serious threat to safe mining of the working face.
The direct roof of the 3 coal seam is siltstone, ranging from 3.22 to 6.33 m, with an average of 4.36 m. The basic roof is dominated by interbeds of medium to fine sandstone, with a thickness of 10.69–17.06 m, with an average of 12.67 m. The thickness is uniform, but abundant fissures are developed. False tops occur, mostly mudstone, aluminous mudstone, or carbonaceous mudstone. The direct bottom is sandy mudstone with a thickness of 0.00–2.40 m and an average of 1.20 m. The basic bottom is fine sandstone with a thickness of 5.00–5.05 m and an average of 5.02 m, which is relatively stable.
Water richness analysis
Results of the observation of the water level in an observation hole, indicate that the lower group of the Quaternary, i.e., the "bottom containment", is the main water-filled aquifer on the roof of the 331 working face, which has no necessary hydraulic connection with other aquifers. The unit water inflow q is 0.002 3–0.074 274 L/(s∙m), demonstrating that the water richness is weak, and the replenishment is not smooth. It is a weak water rich aquifer, and the current water level shows only minor changes. The cohesive soil layer at the bottom of the Quaternary system is a hard, semi-consolidated and dense water-saturated soil with low compressibility, poor permeability, and good expansion. The soil layer is an effective cohesive soil water barrier with a variable thickness of 0.00–5.74 m.
Numerical simulation
Construction of a numerical model
At first we established the FLAC3D numerical simulation model was first to study the risk of water gushing and sand inrush caused by the activation of faults in the 331 working face of Yangcun Coal Mine during the mining process. Considering the geological conditions of the 331 working face, the size of the model is 260 m × 50 m × 104 m (the model heights are 84 m and 94 m when the bedrock thickness is 20 m and 30 m, respectively). Horizontal constraints were applied to the front, rear, and left and right boundaries. The bottom boundary was fixed. The the upper part is a free boundary and a load of 3.3 MPa is applied to replace the overlying gravity. The water pressure of the loose layer is set to 0.4 MPa. The Molecular-Coulomb criterion is used for the mechanical calculation, and an isotropic, uniform, and equivalent continuum model is used for fluid calculation. The left and right sides of the model are left to protect coal pillars. The coal thickness is 8 m and the coal mining process is fully mechanical (along the coal seam floor). The mining height is 3 m and the mining method is the forward type, gradually approaching the fault with an advance of 10 m each time towards the fault. The monitoring points A, B, and C are arranged in the belt, 5 m, 15 m, and 25 m away from the upper part of the coal seam, respectively, as shown in Fig. 3.
According to the results of the on-site geological investigation and relevant rock mechanics experiments, and considering the size effect of the mine rock mass, suited calculation parameters were selected for the numerical calculation that are summarized in Table 1. To improve the accuracy of the simulation, the seepage parameters of the rock mass after plastic failure were modified with the fish language22.
Overburden and fault failure under different bedrock thickness conditions
Figure 4 shows the plastic failure diagram of the model in the process of working face propulsion for a bedrock thickness of 20 m (shear-n means that the element is currently being shear damaged, shear-p means that the element has been shear damaged before; tension-n means that the element is currently being tension damaged, tension-p means that the element has been tension damaged before). According to the “Regulations for coal pillar retention and coal press mining for building water bodies, railways and main shafts”, the mining height is 3 m below the condition of a medium-hard rock. The height of the caving zone is 6.9–11.3 m. The development height of the fracture zone is 30.1–41.3 m. It is evident that the thickness of the bedrock is not satisfied with the development height of the fracture zone. According to the size of the model and the form of the rock mass failure, the height of the caving zone and the fracture zone can be adjusted23. For a progress of 50 m of the working face, the caving zone develops to 10 m and strops rising. Moreover, the fracture zone has developed to the top of the bedrock. For a advance of 70 m of the working face, the height of the fracture zone does not change, because the clay layer can temporarily inhibit the development of fractures until it is completely destroyed24. At this time, the top of the fault zone starts to be affected by plastic failure, and becomes connected to the fracture zone. The clay layer on-top shows through-type fractures, which connect the overlying loose aquifer to form a water-conducting channel. When the working face advances up to 90 m, a through-type fracture appeared in the clay layer overlying the opening, connecting the loose aquifer to form a water-conducting channel, and the fault and the rock mass of the upper and lower walls became affected by large-scale damage. After 110 m advance of the working face, it had passed through the fault zone for 10 m at this time. The rock mass above the mining face has been completely destroyed, the water-blocking ability of the clay layer has been completely lost, and the fault zone has been rotated due to the mining of the working face25. As a consequence, the original shear failure has been transformed into tensile failure.
Figure 5 shows the plastic failure diagram of the model in the process of working face propulsion for a bedrock thickness of 30 m. When the working face is advanced by 50 m, the caving zone develops to 10 m, and the fracture zone develops to 26 m. At this time, the fault becomes affected by slight shear damage. When the working face is advanced to 70 m, the fracture zone develops to the top of the bedrock and becomes connected with the fault zone failure area. The clay layer overlying the fault is destroyed and connected with the loose aquifer. When the working face is advanced by 90 m, the height of the fracture zone remains unchanged and the clay layer above the incision hole remains unmodified. Partially damaged but not penetrated, it still maintains a good water blocking capacity and the clay layer above the fault is damaged. When the working face advances toward 110 m, the damage range of the clay layer above the incision hole is enlarged and the damage of the clay layer on the upper wall of the fault is low.
Figure 6 shows the plastic failure diagram of the model in the process of working face propulsion for a bedrock thickness of 40 m. When the working face is advanced by 50 m, the fracture zone develops to 26 m and the fault zone becomes affected by plastic failure. When the working face is advanced by 70 m, the fracture zone interacts with the fault plastic zone. When the working face is advanced by 90 m, the fracture zone develops to 40 m. Due to the "barrier" effect of the fault26, the area of the plastic zone on the fault hanging wall is relatively small. When the working face is advanced by 110 m, the height of the fracture zone remains unchanged, but a through-type fracture appears in the clay layer above the fault, linking the water-bearing sand layer with the fault failure area, thus forming a water channel.
Figure 7 shows the distribution of model pore pressure at 32,000 steps when the working face passes through the fault 10 m for different bedrock thicknesses. For a bedrock thickness of 20 m, the overlying rocks and the upper clay layer are all destroyed, causing blocking of the resistance. The water capacity is largely reduced and the water in the loose layer seeps into the working face through the fault and the overlying fissure zone. Because the fault zone is more broken, the seepage speed of the water in the fault zone will be faster and it will merge into the working face earlier. Water inrush will occur along the entire surface. When the bedrock thickness is 30 m, the fractured rock mass above the fault zone and the open incision are the main seepage channel for water in the loose layer. For a bedrock thickness of 40 m, the bedrock thickness is larger than the development height of the fracture zone. The clay layer above the fault zone is damaged. Therefore, the fault zone is the main seepage channel.
This analysis indicates that when the working face advances the same distance, the lower the thickness of the bedrock, the lower the probability of fault failure. The water inrush mode of the working face varies with the different bedrock thicknesses. If all parts are destroyed, a serious risk of water inrush exist at various positions of the working face. When the bedrock thickness is 30 m, the fault zone and the cracks above the opening are the main water-conducting channels. For ae bedrock thickness of 40 m, water is mainly conducted by the fault zone. If the fault is reinforced in advance, the bond degree of the fault zone will be significantly strengthened. Therefore, the upper clay layer will not be affected by the fracture zone and no water conduction channel can form, realizing secure mining conditions across the fault under the thin bedrock.
Simulation analysis of fault grouting reinforcement treatment
In order to realize cross-fault mining in the 331 working face and to prevent water gushing and sand inrush accidents of the working face caused by the activation of the fault, it is necessary to conduct grouting reinforcement on the Quince Tree No. 2 fault in the 331 working face. The grouting reinforcement can fill the interconnected surrounding rock cracks and the closed fissures that cannot be filled with grout can be closed and compressed27, thus improving the strength and water permeability of the rock. However, the effect of grouting reinforcement needs to be analyzed by numerical simulation. Considering the geological mining conditions of the Yangcun Coal Mine, we analyzed the grouting effect. The mechanical parameters selected for the grouting body are summarized in Table 228.
Figure 8 shows the plastic failure diagram of the model after grouting reinforcement. When the working face is advanced to 70 m, the fault is not affect by premature failure. The failure height of the rock mass is the same, indicating that the fault has no additional influence on the fracture. When the working face passes through the fault zone for 10 m, the failure height of the fault zone and the height of the fracture zone reach a certain value and the clay layer is not affected by plastic damage, maintaining a good water resistance. The failure type of the fault zone is shear failure, indicating that the roof collapses normally without formation of a water conduction channel.
Figure 9 shows the slippage of the fault before and after grouting. The starting distance is used to describe the distance between the working face and the fault when the fault first responds. It can be seen from the figure that the starting distance of the fault at the high level is larger without grouting. The starting distance of the fault at the low level is the lowest and all reach the peak slip amount when the working face contacts the fault. The peak value of the slip amount of each layer is inversely proportional to the vertical distance from the fault. After the working face proceeded through the fault, the slip decreases gradually and tends towards a constant value after pushing 30 m through the fault. After the fault grouting, the starting distance of the fault and the peak value of the slip amount in each layer decrease and the peak values of the slip amount at monitoring points A, B, and C decrease accordingly by 10.8%, 58.8%, and 59.6%, indicating that after the fault is strengthened, the slip of the high-level fault is largely reduced. The displacement of monitoring point A is only moderately reduced due to its proximity to the caving zone.
To sum up, after fault grouting reinforcement, the fault zone will not be damaged in advance, the height of fracture development at the fault is suppressed, the slip of high-level faults is reduced, and the impact on the upper clay layer is low. Therefore, the formation of a water channel is prevented and safe recovery across fault is realized.
Field practice verification analysis
To improve secure mining conditions, Yangcun Coal Mine carried out grouting reinforcement on the No. 2 fault in the 331 working face before mining, and then subsequently continued to mining production. The main purpose of this grouting was to strengthen the fault plane, delay the caving time of the roof near the fault, and reduce the development height of the caving zone due to the influence of the fault. The grouting hole is designed at the position of the fault plane 8 m below the Quaternary bottom boundary (Fig. 10), the grout splits and spreads in the fault zone to compact and reinforce the fault fracture zone. Part of the grout continues to diffuse upwards, enters the bottom containment, and reinforces part of the bottom sand layer.
The grouting body is made of pure cement slurry, mainly pure cement slurry and supplemented by double-liquid slurry. A cement with the grade of 42.5 is selected and the concentration of water glass is > 36 Baume degrees. It is suitable for filling wide cracks and cavities. Six different slurry ratios were prepared before grouting. According to the fluidity, rapid setting, economic analysis and actual situation of the slurry, the ratio in Table 3 was selected.
11 preset grouting holes were present. The drilling interval is 10 m and two inspection holes are used for peeping and coring to check the grouting effect (Fig. 11). Only the holes 4# and 7# of the 13 drilling holes have water output. The water output is 0.1 and 2.0 m3/h, respectively. According to the analysis of the water output depth, the water output location should occur in the fault fracture zone. The overall water output holes are rare and single hole output. The water volume is low and there is no obvious water pressure in the effluent, indicating that the fault zone is weak in water richness and poor in water conductivity.
After grouting, we used two inspection holes to conduct drilling peeping (Fig. 11). The peeping depths of the 12# and 13# inspection holes are 86 m and 70 m, respectively, and the depths of the faults are 85.6 m and 61.5 m. The overall structure of the hole wall is relatively stable. Striking weathering fractures in the strata occur at the depth of 71 m and 50 m (Fig. 11). Fault fracture zones are missing in the peeping section. Combined with the grouting amount, drilling construction and coring comprehensive analysis, the conclusion is drawn: The filling is relatively dense and obvious water outflow phenomena are lacking, indicating a good effect of the grouting.
No water gushing, sand gushing, and roof pumping occurred in the 331 working face during the actual mining process, especially when the working face approached and pushed over the Queshu No. 2 fault, the roof fell normally, and abnormal situations did not occur. which verifies the accuracy of our numerical simulation analysis of grouting reinforcement. The safety stoping of the 331 working face was completed on September 5, 2021.
Conclusions
-
(1)
The mechanical properties of the rock mass near the fault interface change and they are related to the cohesive force at the interface. The lower the required strength, on the contrary, the lower the cohesive force of the contact surface, the less strengthened the fault zone, and the larger the strength required for the rock at the contact surface.
-
(2)
The damage degree of the fault zone is related to the bedrock thicknesses during mining: The thinner the bedrock thickness, the lower the fault damage degree, for the same advancing distance. Different modes of water inrush occur: For a bedrock thickness of 20 m, the working face is fully inrush, for a thickness of 30 m the water inrush mainly depends on the fault zone and the fissure zone above the cut hole, and for a thickness of 40 m the water mainly follows the fault zone.
-
(3)
After fault grouting reinforcement, the fault zone of the working face did not fail in advance during the advancing process and had no effect on the development height of the fracture zone. It is small, effectively prevents the seepage of water in the loose layer and provides a meaningful scientific basis for cross-fault mining of coal mine working face under similar conditions.
Data availability
The primary data used to support the findings of this study are available from the corresponding author upon request.
References
Lan, H., Chen, D. K. & Mao, D. B. Current status of deep mining and disaster prevention in China. Coal Sci. Technol. 44, 39–46. https://doi.org/10.3969/j.issn.1673-4076.2020.16.094 (2016).
Sun, W. J., Zhou, W. F. & Jiao, J. Hydrogeological classification and water inrush accidents in China’s coal mines. Mine Water Environ. 35, 214–220. https://doi.org/10.1007/s10230-015-0363-3 (2016).
Wu, Q. Progress, problems and prospects of prevention and control technology of mine water and reutilization in China. J. China Coal Soc. 39, 795–805. https://doi.org/10.13225/j.cnki.jccs.2014.0478 (2014).
Pu, W. K. & Mao, X. B. Reserch on effect of fault dip on fault activation and water inrush of coal floor. Chin. J. Rock Mech. Eng. 28, 386–394. https://doi.org/10.3321/j.issn:1000-6915.2009.02.024 (2009).
Jiang, Y. D., Wang, T., Zhao, Y. X. & Wang, C. Numerical simulation of fault activation pattern induced by coal extraction. Int. J. Min. Sci. Technol. 1, 1–5. https://doi.org/10.13247/j.cnki.jcumt.2013.01.002 (2013).
Li, Q. F., Wang, W. J., Zhu, C. Q. & Peng, W. Q. Analysis of fault water-inrush mechanism based on the principle of water-resistant key strata. J. Min. Saf. Eng. 26, 87–90. https://doi.org/10.3969/j.issn.1673-3363.2009.01.017 (2009).
Li, L. P., Li, S. C., Shi, S. S. & Xu, Z. H. Water inrush mechanism study of fault activation induced by coupling effect of stress-seepage-damage. Chin. J. Rock Mech. Eng. 30, 3295–3304 (2009).
Wang, A. W. et al. Similar experimental study of rockburst induced by mining deep coal seam under fault action. Rock Soil Mech. 35, 2486–2492. https://doi.org/10.16285/j.rsm.2014.09.020 (2014).
Xie, X. P., Huang, Y. Q., Hu, C. M. & Caimeng,. Similar simulation study on the law of mining pressure in “three soft” coal seam near the fault. Min. Saf. Environ. Protect. 46, 45–48 (2019).
Sun, X. Y., Liu, L. D., Li, C. & Miao, L. T. Study on influence of layered mining of extra thick coal seam on faults based on similar materials test. Coal Sci. Technol. 47, 35–40. https://doi.org/10.13199/j.cnki.cst.2019.02.006 (2019).
Shao, J. L. et al. Effects of the borehole drainage for roof aquifer on local stress in underground mining. Geomech. Eng. 24, 479–490. https://doi.org/10.12989/GAE.2021.24.5.479 (2021).
Wang, Z. Y. et al. New type of similar material for simulating the processes of water inrush from roof bed separation. ACS Omega 5, 30405–30415. https://doi.org/10.1021/acsomega.0c03535 (2020).
Shao, J. L., Zhou, F. & Sun, W. B. Evolution model of seepage characteristics in the process of water inrush in faults. Geofluids 10, 1–14. https://doi.org/10.1155/2019/4926768 (2019).
Zhang, P. S., Yang, J., Wang, M. H. & Wang, H. Simulated study on variation of interfacial stress of fault induced by mining under solid-liquid coupling mode. China Min. Mag. 23, 84–89. https://doi.org/10.3969/j.issn.1004-4051.2014.04.020 (2014).
Zhang, P. S. Numerical simulation of silding rule of two plates of fault induced by mining under solid-liquid coupling mode. J. Shandong Univ. Sci. Technol. Nat. Sci. 33, 53–57. https://doi.org/10.16452/j.cnki.sdkjzk.2014.02.012 (2014).
Li, A. et al. Design of longwall coal pillar for the prevention of water inrush from the seam floor with through fault. Geofluids 2021, 1–14. https://doi.org/10.1155/2021/5536235 (2021).
Li, B. & Wu, Q. Catastrophic evolution of water inrush from a water-rich fault in front of roadway development: A case study of the Hongcai coal mine. Mine Water Environ. 38, 521–430. https://doi.org/10.1007/s10230-018-00584-z (2019).
Liu, S., Liu, W. & Yin, D. Numerical simulation of the lagging water inrush process from insidious fault in coal seam floor. Geotech. Geol. Eng. 35, 1–9. https://doi.org/10.1007/s10706-016-0156-x (2017).
Cheng, J. L. et al. Numerical simulations of water-inrush induced by fault activation during deep coal mining based on fluid-solid coupling interaction. Disaster Adv. 6, 10–14. https://doi.org/10.1007/s10230-018-00584-z (2013).
Zhu, C. et al. Investigating toppling failure mechanism of anti-dip layered slope due to excavation by physical modelling. J. Rock Mech. Rock Eng. 53, 1–22. https://doi.org/10.1007/s00603-020-02207-y (2020).
Wang, Z. Y., Zhang, Q. & Zhang, W. Q. A novel collaborative study of abnormal roof water inrush in coal seam mining based on strata separation and wing crack initiation. Eng. Fail. Anal. https://doi.org/10.1016/j.engfailanal (2022).
Xu, S. Y., Zhang, Y. B., Shi, H. & Xiang, X. H. Flow characteristics and experimental study on the permeability of mining-induced fractured rock mass in caving zones. Saf. Environ. Eng. 29, 128–134. https://doi.org/10.13578/j.cnki.issn.1671-1556.20210645 (2022).
Wu, Y. L., Yu, Z. R., Yan, Z. H. & Zhu, S. Y. Numerical simulation of development characteristics of “two zones” of repeated mining at the first face of shallow mining area. Saf. Coal Mines 50, 199–203. https://doi.org/10.13347/j.cnki.mkaq.2019.05.049 (2019).
Yi, S. H., Zhu, W. & Liu, D. M. Study on the failure law of overburden with thin bedrock and thick unconsolidated layers. Coal Eng. 51, 86–91. https://doi.org/10.11799/ce201911019 (2019).
Wang, P. Study on mining effect caused by normal fault and the inducing mechanism of rock burst. J. Shandong Univ. Sci. Technol. Nat. Sci. https://doi.org/10.27275/d.cnki.gsdku.2018.000148 (2018).
Zhang, P. S., Yang, J. & Wang, M. H. Experimental research on fault activation and water inrush induced by mining under solid-liquid coupling mode. Saf. Coal Mines 45, 24–27. https://doi.org/10.13347/j.cnki.mkaq.2014.03.007 (2014).
Liu, Y. Grouting reinforcement design and practice of roadway in fault crushed zone. Coal Min. Technol. 17, 56–58. https://doi.org/10.13532/j.cnki.cn11-3677/td.2012.06.020 (2012).
Li, G., Ma, W., Tian, S., Zhou, H. & Zou, W. Groundwater inrush control and parameters optimization of curtain grouting reinforcement for the Jingzhai tunnel. Geofluids 7, 1–10. https://doi.org/10.1155/2021/6634513 (2021).
Acknowledgements
We acknowledge the financial support from the National Natural Science Foundation of China (Nos. 51774199). We would like to express their gratitude to EditSprings (https://www.editsprings.cn) for the expert linguistic services provided.
Author information
Authors and Affiliations
Contributions
W.Q.Z.: Funding acquisition, project administration, writing-review AND editing. Y.L.: Formal analysis, software, writing-original draft, investigation, data curation. J.L.S.: Investigation, supervision,validation. X.N.W.: Methodology, Investigation, concepyualization. S.L.: Inverstigation, sofeware, resources. C.Q.M.: Inverstigation, supervision. All authors reviewed the manuscript.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Zhang, W., Lei, Y., Shao, J. et al. Simulation of the activation of mining faults and grouting reinforcement under thick loose layer and thin bedrock. Sci Rep 12, 17049 (2022). https://doi.org/10.1038/s41598-022-21654-x
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-022-21654-x
- Springer Nature Limited
This article is cited by
-
Mining-induced fault failure and coseismic slip based on numerical investigation
Bulletin of Engineering Geology and the Environment (2024)
-
Research and engineering practice on space characteristics of gangue slurry filling
Scientific Reports (2023)
-
Characteristics of an underground stope channel supplied by atmospheric precipitation and its water disaster prevention in the karst mining areas of Guizhou
Scientific Reports (2023)