Abstract
Femtosecond (fs) x-ray pulses are a key tool to study the structure and dynamics of matter on its natural length and time scale. To complement radio-frequency accelerator-based large-scale facilities, novel laser-based mechanisms hold promise for compact laboratory-scale x-ray sources. Laser-plasma driven undulator radiation in particular offers high peak-brightness, optically synchronized few-fs pulses reaching into the few-nanometer (nm) regime. To date, however, few experiments have successfully demonstrated plasma-driven undulator radiation. Those that have, typically operated at single and comparably long wavelengths. Here we demonstrate plasma-driven undulator radiation with octave-spanning tuneability at discrete wavelengths reaching from 13 nm to 4 nm. Studying spontaneous undulator radiation is an important step towards a plasma-driven free-electron laser. Our specific setup creates a photon pulse, which closely resembles the plasma electron bunch length and charge profile and thus might enable novel methods to characterize the longitudinal electron phase space.
Similar content being viewed by others
Introduction
Since they match the intrinsic length and time scales of matter, femtosecond (fs) x-ray pulses are ubiquitously applied as an important tool in many scientific disciplines for solving previously unknown structures1,2,3 and accessing atomic and molecular dynamics4,5. Today, the required high-brightness x-ray beams are provided to the user community almost exclusively by large-scale synchrotron6,7 and free-electron laser facilities8,9,10,11, which represent mature and highly developed technologies, delivering well-characterized photon beams with exceptional availability and reproducibility. Due to their size and cost, however, access to these important resources is very limited.
Laser-driven sources of high brightness particle12,13,14,15,16 and x-ray beams17 are promising to complement established facilities by offering easy access to compact, laboratory-scale femtosecond x-rays that are intrinsically synchronized to the optical driver and thus enable sub-fs temporal resolution in pump-probe experiments. These prospects have motivated a large variety of concepts for laser-driven x-ray sources, including high-harmonic generation18,19 or plasma lasers20, as well as novel acceleration schemes, like THz acceleration21,22,23, dielectric laser acceleration24,25, or laser-plasma acceleration12,13, which can generate x-rays from laser-driven relativistic electron beams26,27,28,29,30,31,32,33.
Laser-plasma acceleration in particular is a promising laboratory-scale technique to generate ultra-relativistic electron beams. Here, the interaction of a terawatt-class laser with an under-dense plasma creates a density modulation, i.e., plasma wave, trailing the laser, which traps and accelerates electrons from the plasma background. The field gradients supported by the plasma wave are orders of magnitude stronger than in a conventional radio-frequency (RF) driven cavity and as a result, the acceleration distance required for typical GeV-level electron beams can be as short as a few centimetres34,35,36,37. In this process, the plasma wavelength, which is typically on the order of 10 microns, determines the characteristic time and length scale. It limits the length of the generated electron bunch to a few femtoseconds38,39,40, supports electron beam currents of several kA40,41, and provides the optical synchronisation between driver laser and electrons. Those characteristics make plasma-generated electron beams appealing for driving a next-generation compact undulator or free-electron laser29,30,31 sources.
Creating stable and reproducible high-quality electron beams from a plasma is, however, conceptually and experimentally very challenging, as the technology is still less developed compared to conventional accelerators. While the small characteristic scale of the plasma wave supports extreme temporal resolution, it also makes it very difficult to diagnose and precisely control the laser-plasma interaction. As a consequence, plasma-driven electron beams available today provide inferior beam quality compared to RF-based accelerators, especially in terms of electron beam energy spread, and typically feature a jitter in central energy of a few-percent. Since an undulator effectively acts as a brightness converter, this electron beam quality is imprinted on the generated photon pulses.
To date, only few experiments42,43,44,45,46,47 have experimentally shown undulator radiation from a laser-plasma accelerated electron beam. Plasma-driven undulator radiation was generated first in the visible42 at 740 nm with 7.5% FWHM bandwidth, using electron beams of 65 MeV energy and achieving a beam brightness of 6.5 × 1016 photons/s/mrad2/mm2/0.1% bandwidth. Soft x-ray undulator radiation at 17 nm central wavelength and 22% FWHM relative bandwidth was demonstrated43 using 200 MeV electrons, achieving a beam brightness of 1.7 × 1017 photons/s/mrad2/mm2/0.1%. Other groups reported 210 nm wavelength44, broadband undulator radiation with a peak around 30 nm45, and 200 nm46 at similar bandwidths. We have recently been made aware of ref. 47, which provides a more detailed study of the undulator radiation presented in ref. 46. Here, the authors report on a plasma-driven undulator source with 7.6% FWHM bandwidth and a brightness of 6 × 1017 photons/s/mrad2/mm2/0.1%. The emitted wavelength is tuneable in the range of 200 nm to 300 nm by varying the undulator gap and electron beam energy.
Studying the generation of spontaneous, i.e., incoherent, undulator radiation using the plasma-generated electron beams available today, these experiments represent important steps towards the ultimate goal of a plasma-driven free-electron laser.
Previously reported undulator radiation often featured an on-target central wavelength, that was mainly determined by fluctuations of the electron beam energy. The resulting radiation bandwidths varied from shot-to-shot, due to instabilities in the electron beam properties, which limited the application of this radiation even the simplest experiments.
Here we show, plasma-driven undulator radiation tuneable in discrete steps over more than one octave from 13 nm to the water-window at 4 nm. Using a set of custom-designed multilayer mirrors, we effectively monochromatize the undulator radiation central wavelength and, as a result, provide discrete wavelengths at sub-nm precision with one-percent relative bandwidth. Our specific setup creates a photon pulse, which closely resembles the electron bunch length and charge profile, and thus opens a new path to study the laser-plasma acceleration mechanism.
Results
Experimental setup
To generate wavelength-tuneable few-nm plasma-driven undulator radiation, we use the Atlas TW-class Ti:Sapphire laser system (see Methods) in an experimental setup illustrated in Fig. 1. The laser is focused into a variable-length hydrogen-filled plasma cell40,48,49, where it drives a plasma wave to generate electron beams in the self-injection regime. The electron beams are collimated using a pair of in-vacuum permanent-magnet quadrupole lenses50 and are then propagated through an undulator, i.e., a periodic arrangement of dipoles, which forces electrons onto a sinusoidal trajectory. In their mean rest frame, the oscillating electrons emit dipole radiation which is Doppler-shifted in the laboratory frame, where the observed on-axis radiation wavelength λ follows the well-known equation
Here, K is the dimensionless undulator parameter, which characterizes the strength of the on-axis magnetic field, λu is the magnetic field period, and \(\gamma =E/m{c}^{2}\) is the normalized electron beam energy. As λ scales quadratically with γ, changing the electron beam energy enables tuning of the undulator radiation over a broad spectral range. Undulator radiation is linearly polarized. In our setup, the compact undulator can be rotated around the beam axis to provide x-rays of s- and p-polarization.
After the undulator, a permanent magnet dipole disperses the electron beam onto a scintillating screen to measure the electron beam spectrum and to separate the x-ray from the electron beam. Following the dipole magnet, curved multilayer mirrors can selectively be moved in the x-ray beam path to focus the undulator radiation into a spectrometer based on a gold transmission grating51. The undulator radiation bandwidth, Δλ, scales with the electron beam spectral width, i.e., \(\Delta \lambda /\lambda \sim 2\Delta \gamma /\gamma \), and is initially very broad due to the large electron energy spread, Δγ. The multilayer mirrors effectively monochromatize the undulator radiation at a well-defined wavelength and any instabilities inherited from the electron beam are converted into a single parameter: the photon number per pulse. We use three custom multilayer designs, which are optimized for a narrowband reflectivities around 13.0 nm, 6.2 nm, and 4.2 nm, respectively. Each multilayer mirror is combined with a thin metal filter of appropriate transmission window to suppress parasitic visible and scattered laser light, as well as possible dipole radiation from the electron spectrometer dipole.
Few-nm undulator radiation
To generate undulator radiation of a particular wavelength, our experimental procedure is as follows. A key factor enabling tuning of the X-ray wavelength is control over the electron energy. Thus, we first optimize the plasma density and target length, i.e., the field gradient inside the plasma cavity and the total acceleration distance, to generate the desired electron energy according to Eq. (1). Limited by the available drive laser parameters, the plasma target supports an electron peak energy tuneable in the range of 230 to 410 MeV. Second, we adopt the beam transport and account for the energy-dependent focal length of the fixed-gradient quadrupole lenses by adjusting their longitudinal position to collimate the selected target electron energy through the undulator. Using a multilayer mirror to transport the generated undulator radiation further monochromatizes the emitted spectrum and effectively provides a fixed wavelength and bandwidth at the detector. Following this procedure, we stepwise tune the emitted wavelength from 13 nm, to 6 nm, to 4 nm in a single experiment shift.
Using an electron energy of 230 MeV, we expect to generate undulator radiation at 13 nm, or 95 eV. The corresponding measured single-shot undulator radiation spectra are shown in Fig. 2, using a gold-coated mirror (blue) and a multilayer mirror (red) to transport the photons from the undulator to the spectrometer.
The gold-coated mirror reflects over a wide spectral range and the detected undulator radiation is broadband, Δλ/λ ≈ 0.3. The bandwidth is determined by the chromaticity of the electron beam optic, which effectively acts as a bandpass filter (ΔE/E ≈ 0.15) for the electron beam43, see also Supplementary Fig. 3.
In contrast, the multilayer mirror acts as a monochromator and thus provides a reproducible central x-ray wavelength and bandwidth independent of the stability of electron beam parameters. The spectrum measured with the multilayer mirror has a ±1st diffraction order at 13.0 nm and a shot-to-shot reproducibility of 0.2 nm rms, which verifies this effect. The relative bandwidth of 3% rms is set by the multilayer mirror reflectivity, which has been independently characterized by the soft x-ray reflectometer at the Advanced Light Source (ALS)52. An experimental characterization of all custom multilayer mirrors is presented in Supplementary Fig. 1.
Note, that the width of the ±1st diffraction orders, shown in Fig. 2, is dominated by the 500 µm size of the spectrometer entrance slit and therefore appears to be broader than 3%.
In principle, the mirror reflectivity can be designed for any central wavelength and bandwidth in the energy regime specified above. For example, generating the corresponding electron energy, tuning the setup and using a tailored multilayer mirror, we measure undulator radiation at 6.2 nm (199.5 eV) and 1.6% relative bandwidth. Generating even shorter wavelengths, we reach into the water-window at 4.2 nm (296.6 eV), which is the highest photon energy from a plasma-driven undulator reported to date and shown in Fig. 3.
Here, the presented spectrum (blue) is averaged over 10 shots, as our specific multilayer design in combination with the metal filter and the spectrometer grating had a combined efficiency of only 0.04% causing a low signal on the detector. An improved mirror design53 would increase the signal level by a factor of 3 and using a gracing incidence geometry would further increase the photon transport efficiency (see Supplementary Fig. 2) in future measurements. The measured undulator radiation relative bandwidth at 4 nm is 1% rms, verified by an independent characterization of the multilayer mirror. X-rays are detected in 92% of the drive laser shots.
At 4 nm the number of emitted photons per pulse within 1% rms bandwidth is 2.5 × 105 with a shot-to-shot fluctuation of 30% rms (see Methods), which agrees well with the shot-to-shot fluctuations in charge.
To provide an order-of-magnitude estimation for the peak brightness54 of our setup at 4 nm we use a previous characterization of the variable-length plasma target48, which reported a normalized emittance of 0.4 mm.mrad. Note, that as the undulator radiation at a certain wavelength is generated from electrons with a particular energy, the energy-resolved emittance is the quantity relevant for this discussion. With the beam optics set to collimate a 410 MeV beam, we calculate a beam size in the undulator of about 100 µm by 375 µm rms using a particle tracking code. Assuming a 5-fs bunch length, which was independently measured for the variable-length plasma target40, and with 104 photons in 0.1% bandwidth emitted from the undulator, we estimate an upper limit for the peak brightness of 1019 photons/s/mrad2/mm2/0.1% bandwidth54. The on-target brightness is lower due to losses in the photon transport. Due to the energy spread, it is difficult to experimentally verify the electron beam size, which is a dominating factor in the calculation of the undulator brightness. Electrons off the design energy are not matched to the beam transport and feature a large beam size. In the experiment, the beam size is measured after the undulator using a scintillating screen. A scintillating screen cannot resolve different energies and all electrons contribute to the measured spot, which is therefore larger compared to a monochromatic 410 MeV beam relevant for emission at 4 nm. An over-estimated electron beam size results in an under-estimated photon brightness. Using only the electron beam size measured at the scintillating screen, we conservatively derive a peak brightness of order 1017 photons/s/mrad2/mm2/0.1% bandwidth at 4 nm from the undulator. This range for the estimated brightness is consistent with results reported by other groups for a laser-plasma undulator source42,43,44. Due to the variations in photon flux, we expect a shot-to-shot fluctuation of the beam brightness by at least 30% rms, which, however, we could not directly verify experimentally due to the above-mentioned constraints.
Discussion
Laser-driven x-ray sources, including high harmonic generation18,19, laser-driven undulators42,43,44,45,46, betatron radiation26,27,28 and Compton scattering32,33, each are based on fundamentally different physical mechanisms, typically cover distinct and complementary ranges of the x-ray spectrum, and provide different performance in key characteristics, such as the peak and average photon flux, coherence, the pulse repetition rate, and the scalability towards shorter wavelengths. It is therefore difficult, and beyond the scope of this work, to directly compare laser-based techniques. Eventually, laser-based sources will form a set of complementary tools, each providing specific benefits for certain applications. Here we discuss the prospects and potential of a laser-plasma driven undulator.
Using laser-plasma accelerated, GeV-level electron beams available in experiments today, plasma-driven undulator radiation can, in principle, cover a range from few to sub-nm wavelengths, while providing a high peak photon flux at a Hz-level repetition rate. The performance is mainly determined by the available drive laser repetition rate and the electron beam quality. The photon bandwidth scales with the beam energy spread providing 10%-level bandwidths for currently available laser-plasma beams. Any quality improvement in the electron beam directly benefits the generated photon bandwidth.
In our experiment, the photon energy of the undulator radiation was limited by the maximum electron beam energy we could achieve, which was, in turn, limited by the available energy of the laser pulses. To further reduce the undulator radiation bandwidth to a 1% level, we applied spectral filtering using custom multilayer mirrors.
Increasing electron energies to the GeV-level, which has already been demonstrated in several laboratories34,35,36,37, would enable us to extend our source into the few Angstrøm regime. For example, we expect of order 104 photons on target at 7 Å (1.8 keV), 1% rms bandwidth and few-fs pulse length using a 1 GeV electron beam with our current undulator and an already fabricated and characterized multilayer mirror of 50% reflectivity. While our current setup is limited to a stepwise tuning owing to the discrete wavelengths supported by the multilayer mirrors, a future extension with a monochromator based on a multilayer mirror pair could provide continuous wavelength tuning.
Plasma-driven undulator radiation offers, in principle, new possibilities to diagnose the temporal properties of the electron beam, which is difficult to access using other techniques55. The undulator pulse duration is a good representation of the electron bunch duration if the slippage between the electrons and the generated x-rays in the undulator is limited. This condition requires a short undulator, i.e., a small number of undulator periods Nu, and a wavelength λ much shorter than the electron bunch length σz, i.e., a few-nm wavelength for an electron bunch of few-fs duration such that \({N}_{u}\times \lambda \ll {\sigma }_{z}\).
With a mirror of broadband reflectivity, e.g., a gold-coated mirror, the full spectrum from a plasma-driven undulator pulse can be transported to an interaction point, to measure the photon pulse length as a representative of the electron bunch length. Laser-based streaking, for example, is a well-established technique in attosecond pulse metrology19 and has previously been used to characterize x-ray pulse durations56,57.
In principle, one could also gain access to longitudinal electron phase space. We propose to repeatedly measure the undulator pulse length using multilayer mirrors of increasing bandwidth. A chirped electron bunch would result in a measured undulator pulse length that is proportional to the bandwidth of the selected multilayer mirror. To perform such a measurement, we would require an additional set of custom design multilayer mirrors, each having a slightly different bandwidth. Note, that our setup already fulfils the important requirements \({N}_{u}\times \lambda \ll {\sigma }_{z}\), i.e., providing low slippage between the electron bunch and the undulator pulse.
In its current configuration, our setup generates synchrotron-like, i.e., incoherent, undulator radiation. Compared to state-of-the-art high-harmonic sources, the repetition rate of our setup is low and limited by the drive laser.
Ultimately, the goal of the community is to operate a plasma-driven undulator in the free-electron laser regime29,30,31, providing a compact source of high-brightness coherent few-fs x-rays. Free-electron laser operation, however, requires exceptional electron beam quality, which is not yet available from a laser-plasma accelerator. Studying the spontaneous emission regime, demonstrating key features of plasma-driven undulator radiation, offering new paths for advanced electron beam diagnostics, and thereby advancing the field are important steps in the development of a laser-plasma driven free-electron laser.
Methods
Electron beams
We use the Atlas Ti:Sapphire laser system (1.5 J in 28 fs FWHM, corresponding to a peak power of ~50 TW) at the Max-Planck-Institute for Quantum Optics (Garching, Germany), focused with a f/20 off-axis parabola to a spot size of 20 µm and providing an intensity of 6.4 × 1018 W/cm2, corresponding to a normalized intensity of a0 = 1.7. The laser operates with a repetition rate of one shot every few seconds, determined by the gas load from the plasma target. Electrons beams are generated in a self-injection regime using a variable-length (3–7 mm) plasma cell target, described and characterized in refs. 48,49. Filled with hydrogen up to a pressure of 130 mbar, corresponding to a plasma density of 3.2 × 1018 cm−3, and operated with optimized parameters48 the target provides electron beams with up to ~2 mrad FWHM divergence. Due to geometrical constraints the spectrometer can only measure electron energies above 200 MeV. Above 200 MeV, the electron beam spectrum contains 50 pC of charge. The electron spectra are broadband and feature a high-energy peak. During the experiment, the electron peak energy, E, is tuned in the range from 230 to 410 MeV by varying the target gas pressure and length. The electron beam optic is chromatic and acts as a bandpass filter, ΔE/E ≈ 0.15 for the electron beam43.
We model the electron beam optics using the Elegant58 and Madx codes and tune the longitudinal position of the quadrupoles for each electron beam energy to collimate the beam through the undulator. The permanent magnet quadrupole lenses have focal lengths of f1 = 11.4 cm and f2 = −17.3 cm for a 410 MeV beam. To measure the electron spectra a permanent magnet dipole of 40 cm length and on-axis field of 0.9 T disperses the electron beam on a charge-calibrated59 scintillating screen.
X-Rays: We use a 60-period miniature undulator (undulator period λu = 5 mm, undulator parameter K = 0.37) to generate undulator radiation. As the undulator has a fixed gap, the wavelength has to be tuned by changing the electron beam energy. The undulator radiation is collected either using an in-house gold-coated mirror, or a set of in-house manufactured multilayer mirrors. The multilayer mirrors are produced with a dual ion beam sputtering system at the Max-Planck-Institute of Quantum Optics, generating a sequence of molybdenum/silicon or chromium/scandium layers60,61 on spherical super-polished fused silica substrates with 2 m radius of curvature. We achieve a surface roughness and interface roughness on the order of 0.4 nm, which is crucial to obtain high reflectivities. The layer design and the 45° angle of incidence tailors the reflectivity of the mirror to a specific central wavelength and bandwidth according to the Bragg equation and the number of contributing layer pairs. The mirror reflectivities have been independently measured at the reflectometry beamline at the Advanced Light Source (Berkeley, USA). We characterize the undulator radiation with a transmission grating based spectrometer. A filter wheel equipped with thin metal filters of aluminium (Al, 300 nm thick), zirconium (Zr, 250 nm thick), palladium (Pd, 200 nm thick), and indium (In, 250 nm thick), reduces residual stray light from the electron drive laser and pre-selects the wavelength range of the spectrometer. The spectrometer offers slit sizes of 100 µm, 250 µm and 500 µm width. By reducing the slit size, we trade spectral resolution for photon flux on the detector. The x-rays are dispersed by 1008 l/mm free-standing gold transmission grating51 onto the x-ray CCD camera, which has a 1st diffraction order efficiency of 8% in the wavelength range of interest. We use a Princeton Instruments Pixis XO-2048B and a Pixis XO-400B CCD camera, of 13.5 × 13.5 µm2 and 20 × 20 µm2 (XO-400B) pixel size and cool the chip below −20 °C to reduce thermal noise. To confirm that the generated signal is undulator radiation, we record a spectrum using a gold-coated broadband mirror and verify that the ±1st diffraction order shows the characteristic and well-known red-shift with observation angle, i.e., \(\lambda \propto {\theta }^{2}\). The photon number per pulse is determined summing the photon counts on the CCD image (with background subtracted) and accounting for the quantum efficiency of the chip, the transmission of the x-ray filters and the reflectivity of the multilayer mirrors. For these measurements, the entrance slit and the grating are removed from the x-ray beam path. At 4 nm, we obtain 2.5 × 105 photons in 1% bandwidth, generated from 4 pC of charge in the contributing range of the electron spectrum. Using a simple analytical estimation for a thin (filament) electron beam resonantly emitting on axis54 this charge agrees with the measured number of photons within a factor of 2. We attribute this discrepancy to uncertainties in the spectrometer calibration and the emission from the thick electron beam. Gamma ray hits (hot pixels) are eliminated from the raw CCD image using a threshold filter. For the analysis presented in Fig. 2, we additionally apply a 3 × 3 pixels median filter to the camera images (shown as insets). The lineouts are taken after the hot pixel removal. To measure x-ray spectra at 4 nm wavelength we remove the entrance slit and bin 4 × 4 camera pixels for increased sensitivity and reduced noise level.
Data availability
The data is available from the corresponding authors upon reasonable request.
References
Neutze, R., Wouts, R., van der Spoel, D., Weckert, E. & Hajdu, J. Potential for biomolecular imaging with femtosecond X-ray pulses. Nature 406, 752 (2008).
Chapman, H. N. et al. Femtosecond diffractive imaging with a soft-X-ray free-electron laser. Nat. Phys. 2, 830 (2006).
Chapman, H. N. et al. Femtosecond X-ray protein nanocrystallography. Nature 470, 73 (2011).
Young, L. et al. Femtosecond electronic response of atoms to ultra-intense X-rays. Nature 466, 56 (2010).
Seddon, E. A. et al. Short-wavelength free-electron laser sources and science: a review. Rep. Prog. Phys. 80, 115901 (2017).
Bilderback, D. H., Elleaume, P. & Weckert, E. Review of third and next generation synchrotron light sources. J. Phys. B 38, 773 (2005).
Khan, S. et al. Femtosecond undulator radiation from sliced electron bunches. Phys. Rev. Lett. 97, 074801 (2006).
McNeil, B. W. J. & Thompson, N. R. X-ray free-electron lasers. Nat. Photon. 4, 814 (2010).
Ackermann, W. et al. Operation of a free-electron laser from the extreme ultraviolet to the water window. Nat. Photon. 1, 336 (2007).
Emma, P. et al. First lasing and operation of an ångström-wavelength free-electron laser. Nat. Photon. 4, 641 (2010).
Ishikawa, T. et al. A compact X-ray free-electron laser emitting in the sub-ångström region. Nat. Photon. 6, 540 (2012).
Tajima, T. & Dawson, J. M. Laser electron accelerator. Phys. Rev. Lett. 43, 267 (1979).
Esarey, E., Schroeder, C. B. & Leemans, W. P. Physics of laser-driven plasma-based electron accelerators. Rev. Mod. Phys. 81, 1229 (2009).
Roth, M. et al. Bright laser-driven neutron source based on the relativistic transparency of solids. Phys. Rev. Lett. 110, 044802 (2013).
Macchi, A., Borghesi, M. & Passoni, M. Ion acceleration by superintense laser-plasma interaction. Rev. Mod. Phys. 85, 751–793 (2013).
Daido, H., Nishiuchi, M. & Pirozhkov, A. S. Review of laser-driven ion sources and their applications. Rep. Prog. Phys. 75, 056401 (2012).
Corde, S. et al. Femtosecond x rays from laser-plasma accelerators. Rev. Mod. Phys. 85, 1 (2013).
Corkum, P. B. Plasma perspective on strong field multiphoton ionization. Phys. Rev. Lett. 71, 1994 (1993).
Krausz, F. & Ivanov, M. Attosecond physics. Rev. Mod. Phys. 81, 163 (2009).
Zeitoun, P. et al. A high-intensity highly coherent soft X-ray femtosecond laser seeded by a high harmonic beam. Nature 431, 426 (2004).
Wong, L. J., Fallahi, A. & Kärtner, F. X. Compact electron acceleration and bunch compression in THz waveguides. Opt. Express 21, 9792 (2013).
Nanni, E. A. et al. Terahertz-driven linear electron acceleration. Nat. Commun. 6, 8486, https://doi.org/10.1038/ncomms9486 (2015).
Zhang, D. et al. Segmented terahertz electron accelerator and manipulator (STEAM). Nat. Photon. 12, 336 (2018).
England, R. J. et al. Dielectric laser accelerators. Rev. Mod. Phys. 86, 1337 (2014).
Breuer, J. & Hommelhoff, P. Laser-based acceleration of nonrelativistic electrons at a dielectric structure. Phys. Rev. Lett. 111, 134803 (2013).
Rousse, A. et al. Production of a keV X-Ray beam from synchrotron radiation in relativistic laser-plasma interaction. Phys. Rev. Lett. 93, 135005 (2004).
Kneip, S. et al. Bright spatially coherent synchrotron X-rays from a table-top source. Nat. Phys. 6, 980 (2010).
Wenz., J. et al. Quantitative X-ray phase-contrast microtomography from a compact laser-driven betatron source. Nat. Commun. 6, 7568, https://doi.org/10.1038/ncomms8568 (2015).
Grüner., F. et al. Design considerations for table-top, laser-based VUV and X-ray free electron lasers. Appl. Phys. B 86, 431 (2007).
Maier, A. R. et al. Demonstration scheme for a laser-plasma-driven free-electron laser. Phys. Rev. X 2, 031019 (2012).
Loulergue, A. et al. Beam manipulation for compact laser wakefield accelerator based free-electron lasers. New J. Phys. 17, 023028 (2015).
Khrennikov, K. et al. Tunable all-optical quasimonochromatic thomson x-Ray source in the nonlinear regime. Phys. Rev. Lett. 114, 195003 (2015).
Powers, N. D. et al. Quasi-monoenergetic and tunable X-rays from a laser-driven compton light source. Nat. Photon. 8, 28 (2014).
Leemans, W. P. et al. GeV electron beams from a centimetre-scale accelerator. Nat. Phys. 2, 696 (2006).
Leemans, W. P. et al. Multi-GeV electron beams from capillary-discharge-guided subpetawatt laser pulses in the self-trapping regime. Phys. Rev. Lett. 113, 245002 (2014).
Walker, P. A. et al. Investigation of GeV-scale electron acceleration in a gas-filled capillary discharge waveguide. N. J. Phys. 15, 045024 (2013).
Wang, X. et al. Quasi-monoenergetic laser-plasma acceleration of electrons to 2 GeV. Nat. Commun. 4, 1988, https://doi.org/10.1038/ncomms2988 (2013).
Buck, A. et al. Real-time observation of laser-driven electron acceleration. Nat. Phys. 7, 543 (2011).
Lundh, O. et al. Few femtosecond, few kiloampere electron bunch produced by a laser-plasma accelerator”. Nat. Phys. 7, 219 (2011).
Heigoldt, M. et al. Temporal evolution of longitudinal bunch profile in a laser wakefield accelerator. Phys. Rev. ST Accel. Beams 18, 121302 (2015).
Couperus, J. P. et al. Demonstration of a beam loaded nanocoulomb- class laser wakefield accelerator. Nat. Commun. 8, 487, https://doi.org/10.1038/s41467-017-00592-7 (2017).
Schlenvoigt, H.-P. et al. A compact synchrotron radiation source driven by a laser-plasma wakefield accelerator. Nat. Phys. 4, 130 (2008).
Fuchs, M. et al. Laser-driven soft-x-ray undulator source. Nat. Phys. 5, 826 (2009).
Anania, M. P. et al. An ultrashort pulse ultra-violet radiation undulator source driven by a laser plasma wakefield accelerator. Appl. Phys. Lett. 104, 264102 (2014).
Shaw, B. et al. Undulator radiation from laser-plasma-accelerated electron beams. AIP Conf. Proc. 1507, 310 (2012).
André, T. et al. Control of laser plasma accelerated electrons for light sources. Nat. Commun. 9, 1334, https://doi.org/10.1038/s41467-018-03776-x (2018).
Ghaith, A. et al. Tunable High Spatio-Spectral Purity Undulator Radiation from a Transported Laser Plasma Accelerated Electron Beam. Sci. Rep. 9, 19020 (2019).
Popp, A. Dynamics of electron acceleration in laser-driven wakefields: Acceleration limits and asymmetric plasma waves. PhD thesis, Ludwig-Maximilians Universität München (2011).
Weingartner, R. Characterisation of the transverse emittance of laser-wakefield-accelerated electrons. PhD thesis, Ludwig-Maximilians Universität München (2018).
Eichner, T. et al. Miniature magnetic devices for laser-based, table-top free-electron lasers. Phys. Rev. ST Accel. Beams 10, 082401 (2007).
Predehl, P. et al. Grating elements for the AXAF low-energy transmission grating spectrometer. Proc. SPIE 1743, 475 (1992).
Gullikson, E. M., Mrowka, S. & Kaufmann, B. J. Recent developments in EUV reflectometry at the Advanced Light Source. Proc. SPIE 4343, 363 (2001).
Guggenmos, A. et al. Ion polished Cr/Sc attosecond multilayer mirrors for high water window reflectivity. Opt. Express 22, 26526 (2014).
Clarke, J. A. The science and technology of undulators and wigglers (Oxford Univ. Press, Oxford, 2006).
Downer, M. C., Zgadzaj, R., Debus, A., Schramm, U. & Kaluza, M. C. Diagnostics for plasma-based electron accelerators. Rev. Mod. Phys. 90, 035002 (2018).
Grguras, I. et al. Ultrafast X-ray pulse characterization at free-electron lasers. Nat. Photon. 6, 851 (2012).
Helml, W. et al. Measuring the temporal structure of few-femtosecond free-electron laser X-ray pulses directly in the time domain. Nat. Photon. 8, 950 (2014).
Borland, M. elegant: A Flexible SDDS-Compliant Code for Accelerator Simulation. Advanced Photon Source LS-287 (2000).
Buck, A. et al. Absolute charge calibration of scintillating screens for relativistic electron detection. Rev. Sci. Instrum. 81, 033301 (2010).
Guggenmos, A. et al. Aperiodic CrSc multilayer mirrors for attosecond water window pulses. Opt. Express 21, 21728 (2013).
Salashchenko, N. N. & Shamov, E. A. Short-period X-ray multilayers based on Cr/Sc. Opt. Commun. 134, 7 (1997).
Acknowledgements
We thank Nicholas Matlis (DESY) for fruitful discussions. The work has been supported by the DFG through the Munich-Centre for Advanced Photonics (MAP), the SFB TR18 framework, and via Euratom via the IPP-MPQ association.
Author information
Authors and Affiliations
Contributions
A.R.M. designed the experiment and analysed the data. A.R.M., N.K., C.W., N.D., J.W., B.Z., A.G. and J.S. carried out the experiment. A.G. designed and produced the multi-layer mirrors. I.D. and A.R.M. characterized the undulator. U.S. designed and realized the undulator and permanent magnet quadrupoles. E.M.G. characterized the multilayer mirrors. A.R.M. and N.K. wrote the manuscript. F.K., S.K., U.K. and F.G. provided overall guidance to the project.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Maier, A.R., Kajumba, N., Guggenmos, A. et al. Water-Window X-Ray Pulses from a Laser-Plasma Driven Undulator. Sci Rep 10, 5634 (2020). https://doi.org/10.1038/s41598-020-62401-4
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-020-62401-4
- Springer Nature Limited
This article is cited by
-
Shaped liquid drops generate MeV temperature electron beams with millijoule class laser
Communications Physics (2024)
-
Prospects for free-electron lasers powered by plasma-wakefield-accelerated beams
Nature Photonics (2024)
-
Attosecond-Angstrom free-electron-laser towards the cold beam limit
Nature Communications (2023)
-
Seeded free-electron laser driven by a compact laser plasma accelerator
Nature Photonics (2023)