Abstract
Three-dimensional spheroids are widely used as cancer models to study tumor cell proliferation and to evaluate new anticancer drugs. Growth-induced stress (i.e., stress that persists in tumors after external loads removal) influences tumor growth and resistance to treatment. However, it is not clear whether spheroids recapitulate the tumor physical properties. Here, we demonstrated experimentally and with the support of mathematical models that, like tumors, spheroids accumulate growth-induced stress. Moreover, we found that this stress is lower in spheroids made of 5,000 cancer cells and grown for 2 days than in spheroids made of 500 cancer cells and grown for 6 days. These two culture conditions associated with different growth-induced stress levels also had different effects on the spheroid shape (using light sheet microscopy) and surface topography and stiffness (using scanning electron microscopy and atomic force microscopy). Finally, the response to irinotecan was different in the two spheroid types. Taken together, our findings bring new insights into the relationship between the spheroid physical properties and their resistance to antitumor treatment that should be taken into account by the experimenters when assessing new therapeutic agents using in vitro 3D models or when comparing studies from different laboratories.
Similar content being viewed by others
Introduction
All tissues are characterized by physical parameters to which cells respond and adapt. Tissue mechanics studies have been developed to understand their stress and strain responses. In the 1990s, Fung and collaborators demonstrated the fundamental importance of residual stress, which corresponds to stress remaining in a tissue when all external loads have been removed1. Making cuts and observing the resulting changes of shape can reveal the presence of residual stresses in a tissue ex vivo. By using this experimental method, the presence of residual stresses has been demonstrated in arterial wall, veins, heart and brain, for instance2,3,4,5. An important conclusion of these studies is that the level of internal stress and strain of organs guides physiological functions.
Tumor micro-regions consist of heterogeneous cancer cell populations that are organized in 3D and in which cell growth and response to anti-tumor drugs are strongly influenced by the 3D architecture, cell-cell junctions and interaction with the microenvironment6,7. Moreover, tumor growth and progression are also strongly influenced by mechanical cues6,7. In solid tumors, cancer cells proliferation imposes elastic strain on the surrounding tumor microenvironment, thus generating a stress created by reciprocal forces between solid tumor and the surrounding normal tissue. Stylianopoulos et al.8 have experimentally demonstrated the presence of residual stresses in murine and human solid tumors. Indeed, partial cut through an excised tumor causes opening due to relaxation of the growth-induced stress in the absence of external loads.
Cells cultured in 2D monolayers have been classically used for the pharmacological evaluation of anticancer drugs. However, over the last decade, the development of 3D cell culture models has significantly changed the landscape of preclinical studies, and 3D spheroid models are now widely used as tumor surrogates. Indeed, spheroids in which cancer cells are cultured as 3D aggregates reproduce the cell-cell and cell-matrix interactions found in solid tumors9. Moreover, spheroids can grow up to several hundred micrometers in diameter, thus progressively displaying a gradient of proliferating cells similar to what observed in tumor micro-regions10. In recent years, technical innovations in the development of dedicated devices and strategies to produce and manipulate spheroids and the marketing of ready-to-use spheroids have tremendously boosted the use of such models for basic research, drug screening, and preclinical studies11,12,13. In parallel, many efforts have been made to develop new technologies to characterize the complex 3D multicellular organization and regionalization of spheroids14,15,16.
Little is known about the physical characterization of 3D spheroids. Centrifugation, parallel-plate compression, micropipette aspiration and fracture of fused spheroids have been used to quantify tissue rheology17,18. However, due to the value of spheroids as in vitro tumor models for pre-clinical studies, it is crucial to complete their physical characterization and to determine whether they display, like tumors, growth-induced stress. Moreover, it is important also to assess the impact of spheroid production methods on their physical properties. To address these issues we first adapted the experimental protocol described by Stylianopoulos et al. to spheroids to demonstrate that growth-induced stress accumulates during the growth of colon adenocarcinoma-derived spheroids. Then, we characterized the spheroid physical properties and investigated how the different seeding and growth duration conditions affect the spheroid structure and the establishment of residual stress. By coupling experimental data with mathematical modeling and simulations, we found that growth-induced stored stress is lower in spheroids made of a high number of cells and grown for shorter time than in spheroids made of fewer cells and grown for longer time. This difference was associated with modifications of the surface topography and local stiffness. Moreover, the different experimental conditions also significantly influenced spheroid response to irinotecan.
Results
Spheroids store growth-induced solid stress
To determine whether tumor spheroids accumulate solid stress, we made a partial incision on each spheroid derived from HCT116 colon carcinoma cells and then monitored the morphological changes by video-microscopy. Such partial cuts resulted in a measurable deformation that involved simultaneously swelling at the center and retraction at the boundary of the spheroid (Fig. 1a and Supplementary Movie 1). In spheroids made starting from 500 cells and grown for 6 days (called thereafter D6-500 spheroids), a clear opening was visible at the site of the cut three minutes after incision.
We quantified the accumulation of growth-induced solid stress using a relaxation index that corresponds to the extent of the post-incision opening normalized to the spheroid diameter before the partial cut (Fig. 1b,c and Supplementary Fig. S1). In parallel, we used a quantitative mathematical model that proposes a method to estimate the stored stress in a spherical domain on the basis of the opening extent and incision depth (and19 see Methods for more details). It assumes that the distribution of the stored stress in a domain at the equilibrium (at rest) results from the relationship between radial and circumferential stored stresses. Combined with a mechanical model of hyperelasticity, it allows simulating the displacement of a spherical domain after an incision. Thus, for a given stored stress, the model predicts the response curve that gives the relaxation index, depending on the incision depth/diameter ratio. To estimate the stored stress predicted by this mathematical model, we made incisions of various depths in D6-500 spheroids and measured the relaxation index for each incision depth. In parallel, we performed a series of simulations for various magnitudes of stored stress, and then compared the obtained response curves with the experimental data (Fig. 2a and Supplementary Fig. S2). We used the stored stress magnitude for which the response curve points belong to the regression line of the experimental points to generate simulated images of spheroid opening that fairly reproduce the experimental observations (Fig. 2b). This analysis allowed determining the stress accumulated within D6-500 spheroids (Fig. 2c). Together, these experimental and mathematical simulation results confirmed the accumulation of solid stress in spheroids at a given growth stage, as reported macroscopically for solid tumors8.
Growth-induced solid stress accumulation depends on spheroid production conditions
Spheroids made starting from 500 cells but grown only for 2 days (D2-500 spheroids) relaxed less after incision compared with D6-500 spheroids (Fig. 1a,c), suggesting that spheroids progressively accumulate solid stress during growth. To exclude that the opening differences between D2-500 and D6-500 spheroids were only the consequence of a volume difference, we compared the response to incision of D6-500 spheroids and of spheroids made from 5,000 cells and grown for 2 days (D2-5000 spheroids). These culture conditions allowed the production of spheroids that reached the same final volume either by proliferation (D6-500 spheroids) or simply by assembling a higher number of cells (D2-5000 spheroids).
Following incision, the opening of D2-5000 spheroids was smaller (Fig. 1a) and relaxation also was significantly lower than in D6-500 spheroids (Fig. 1c). Accordingly, mathematical modeling and simulation indicated that the stored solid stress accumulated during spheroid growth was 1.67-fold higher in D6-500 spheroids (0.276 ± 0.037) than in D2-5000 spheroids (0.166 ± 0.037) (Fig. 2). These data show that growth-induced solid stress is lower in D2-5000 spheroids and that the spheroid production conditions have a very significant impact on this physical property.
Growth-induced solid stress is associated with difference in spherical shape acquisition depending on the spheroid production conditions
We next investigated the relationship between accumulation of solid stress and spheroid multicellular organization. We used light sheet fluorescence microscopy coupled to 3D image analysis to evaluate the volume and flatness of D6-500 and D2-5000 spheroids. To visualize the whole spheroid volume, we used propidium iodide staining and a benzyl alcohol and benzyl benzoate (BABB)-based clearing procedure (see Materials and Methods section) to achieve inner-tissue imaging while preserving the cell morphology and 3D organization15. This visualization method (representative images in Fig. 3a) revealed that D6-500 spheroids were quite spherical, while D2-5000 spheroids displayed a flattened shape in the x-y and x-z axes. Importantly, we could not detect these shape differences by using 2D transmitted-light microscopy (see images in Fig. 1a). Determination of the spheroid flatness confirmed this visual observation. While D6-500 spheroids were almost spherical (0.86 ± 0.08), D2-5000 spheroids were extremely flat (0.30 ± 0.05) (Fig. 3b). Conversely, the spheroid volume was comparable in D6-500 and D2-5000 spheroids (Fig. 3c). These observations indicate that morphological changes and spherical shape are associated with the increase in growth-induced solid stress.
Spheroid surface topology and stiffness are dependent on the production conditions
Analysis of 3D light sheet microscopy images of D6-500 and D2-5000 spheroids suggested that the surface of D2-5000 spheroids was rougher than that of D6-500 spheroids (Fig. 3a). Characterization of the spheroid surface using scanning electronic microscopy showed that the surface of D6-500 spheroids was rather smooth (Fig. 4a and Supplementary Fig. S3). Conversely, the surface of D2-5000 spheroids was more irregular with many cells individually visible at the surface.
Therefore, we investigated the local mechanical properties and measured the spheroid surface stiffness using atomic force microscopy (AFM). The major technical challenge was to immobilize the spheroids for probing the surface with the AFM cantilever. To this aim, we designed and produced 200 µm-high polydimethylsiloxane micro-well arrays with an internal diameter of 450 µm, which corresponds to the spheroid diameter (see Methods and Supplementary Fig. S4). We positioned D6-500 and D2-5000 spheroids in the micro-wells and then analyzed their surface stiffness by measuring the elastic modulus. To take into account the high spheroid size (in relation to the surface analyzed by AFM) and the possible stiffness heterogeneity due to variations between cells and cell-cell junctions, we analyzed different 10 µm2 zones in each spheroid to determine an average Young’s modulus (see Methods section and Supplementary Fig. S4). The Young’s modulus values varied between 2 kPa and 10 kPa, in agreement with data obtained in soft tissues20. The significantly higher Young’s modulus values for D6-500 spheroids than for D2-5000 spheroids (p < 0.001) (Fig. 4b and Supplementary Fig. S4) indicated that D6-500 spheroids are characterized by higher surface stiffness.
These findings show that the spheroid production conditions have a significant impact on the surface topography and mechanical properties, as indicated by the different surface stiffness.
The spheroid production conditions modulate the response to irinotecan
As our results showed that the spheroid production conditions influence the accumulated growth-induced solid stress, spheroid shape, surface topography and surface stiffness, we asked whether these effects could modify the spheroid biological properties, such as the response to anticancer drugs. As an example, we incubated D6-500 and D2-5000 spheroids with increasing concentrations of irinotecan, a widely used chemotherapeutic agent, and then measured the spheroid area from transmitted-light images at 24 h and 48 h to determine the growth inhibition. This is a classical strategy to evaluate the activity of anti-proliferative compounds in 3D models. It does not allow considering the difference in shape, but is compatible with longitudinal recording of live spheroids. Exposure to irinotecan for 48 h resulted in growth inhibition in both spheroid types (representative micrographs in Fig. 5a). Quantification of the growth rate (normalized to untreated control) at 24 h and 48 h of incubation showed that at low irinotecan concentration, the growth rates of D6-500 and D2-5000 spheroids were similar. Conversely, at concentrations higher than 5 µM, irinotecan growth inhibitory effect was stronger in D2-5000 spheroids, and this difference increased with higher concentrations (Fig. 5b). These results indicate that D2-5000 spheroids are more responsive to irinotecan that D6-500 spheroids.
Discussion
The objective of our work was to investigate the physical properties of 3D spheroids and to determine whether, like tumors, they accumulate growth-induced stress8. To this aim, we analyzed the physical and biological properties of spheroids of similar volume obtained by seeding different numbers of cancer cells (500 and 5,000) and culturing them for different amounts of time (6 and 2 days).
We first adapted the experimental protocol described by Stylianopoulos et al. to demonstrate using micro-dissection experiments and mathematical modeling that 3D spheroids accumulate growth-induced solid stress. We then showed that this growth-induced stored stress is lower in D2-5000 spheroids than in D6-500 spheroids. We also found using light sheet microscopy that the spheroid preparation conditions have a critical impact on the spheroid shape. Indeed, D2-5000 spheroids are not spherical (Fig. 3). This result indicates that accumulation of growth-induced stress is central in the 3D multicellular structuration of a cell aggregate that progressively becomes spherical. In agreement, we also found by scanning electron microscopy that the surface topography is different in D2-5000 and D6-500 spheroids, and by AFM that the surface Young’s modulus is higher in D6-500 spheroids. The Young’s modulus values of our HCT116 cell-derived spheroids (between 2000 and 3500 Pa) are comparable with those (230 and 1250 Pa) reported in a recent publication on the first use of micro-tweezers to measure the stiffness of 3D spheroids derived from breast normal and cancer cell lines21. In this previous study, for each cell line, the number of cells to be seeded was chosen to obtain spheroids of the same size, highlighting the fact that adjusting the number of seeded cells is a common experimental habit.
Finally, we showed that accumulation of growth-induced solid stress is associated with a significant modification of the sensitivity to irinotecan. “Young” D2-5000 spheroids were more sensitive than “old” D6-500 spheroids prepared with fewer cells and grown for a longer time. Spheroids are largely used in pre-clinical evaluation because they recapitulate some of the tumor features that are responsible for treatment resistance, including 3D architecture, cell proliferation heterogeneity and cellular physical interactions that constitute potential barriers for drug penetration and distribution9,14. In 3D spheroids, drug sensitivity is linked to the cell proliferation status that is largely dependent on their size9, and on nutrient and oxygen availability16. Here, we show that growth-induced solid stress also plays a central role in the drug response. This could result from modifications in the cell proliferation gradient, or from differences in the amount of extracellular matrix that is involved in the stored stress and represents a barrier for drug diffusion22. Moreover, elevated interstitial fluid pressure has been associated with limited drug penetration within tumors, and its level could be influenced by solid stress8,23. Indeed, solid stress on spheroid could represent a key parameter in a physical barrier to drug diffusion inside spheroids. Hence, it has to be considered together with pathophysiological gradients when using spheroid models for pre-clinical evaluation.
In recent years, multicellular spheroids have taken a remarkable place in the assessment of new drugs and the interest for these 3D models is currently expanding with applications in basic research and also for pharmacological evaluation. Many production methods have been developed to produce batches of 3D spheroids of homogeneous size in a very reproducible way. However, whatever the production method used, an aspect is never explicitly considered by users: the number of cells used at seeding to produce a spheroid of a required size after a given number of days. Indeed, the only considered parameter is the spheroid size at the beginning of the experiment. For reasons often largely dependent on the users’ habits, or in order to comply with experimental or working schedule constraints, experimenters will adjust both the number of seeded cells and the duration of growth, and sometimes will change these parameters from one experiment to another, in order to obtain spheroids of the required size. As pointed out in a recent review, the parameters for the “optimal spheroid” varies depending on the study objectives, and more often than not, the spheroid production protocol and the reasons for choosing a given method are never discussed24.
We consider that our present results should be a warning for the 3D spheroids users’ community. Indeed, the differences in the physical properties/organization and in the response to an anti-tumor agent observed in D2-5000 and D6-500 spheroids should be taken into account by researchers when designing experiments that require 3D spheroids. The parameters of spheroid production must be obligatorily integrated in the assessment and the analysis of results and also for comparison between studies. More generally, tissue engineering is already and will continue to be of tremendous interest for biological research and biomedical applications. Our study demonstrates that special care must be given to the protocol used to produce such tissues to faithfully reproduce the biological and physical properties of a normal tissue.
Methods
Cell culture and spheroid generation
HCT116 colorectal carcinoma cells (ATCC CCL-247) were cultured in Dulbecco’s Modified Eagle’s Medium, (DMEM, Gibco # 11574516) containing 10% fetal bovine serum with 100 U/ml penicillin/streptomycin (GIBCO #11548876). Spheroids were prepared as previously described10,25. Briefly, 500 cells/well or 5,000 cells/well were distributed in home-made poly-HEMA-coated 96-well round bottom plates (with 100 µL of culture medium. Plates were centrifuged (200 g for 6 min) and then placed in a humidified atmosphere of 5% CO2 at 37 °C. This methodology allows obtaining one spheroid per well.
Spheroid incision experiment and opening analysis
For incision experiments, spheroids were processed one-by-one. After 2 days of growth for spheroids prepared starting from 5,000 cells, and after 2 or 6 days of growth for spheroids derived from 500 cells, one spheroid was transferred to a Petri dish in a drop of 20 µl of PBS using a micropipette. The Petri dish was placed on the stage of a MacroFluo Z16 APO microscope (Leica) fitted with a CoolSNAP ES2 CCD camera (Roper). The incision was done manually along the diameter by using an ophthalmic microscalpel (MicroScalpel Feather®, 15°, Electron Microscopy Sciences #72045-15). During the incision process, the experimenter controlled the positioning of the blade on the spheroid and the incision through the microscope. The incision was rapidly done and bright-field images of spheroids were acquired before, immediately, and at 10 and 180 seconds post-incision to measure the incision length, the opening distance (distance between the two sides of the cut) and the spheroid diameter. These values allowed calculating the relaxation index as follows: (opening distance/spheroid diameter)*100.
Analysis of the response to irinotecan treatment
After 6 days (D6-500) or 2 days (D2-5000) of culture, 10 µl of culture medium containing 10 times the required irinotecan (SIGMA #I1406) concentration was added to each well that contained 90 µl of culture medium (n = 6 spheroids/concentration). At the time of irinotecan addition and after 24 h and 48 h of incubation, bright-field images of each live spheroid were acquired with a 5x objective and an inverted microscope (AxioObserver, Zeiss GmbH). Segmentation and shape descriptors were quantified with the ImageJ software26. Growth rates at 24 h and 48 h were calculated for each spheroid, relative to the spheroid area at the time of irinotecan addition. For each experiment, the average growth rate at each irinotecan concentration was normalized to the average growth rate of untreated spheroids.
Light-sheet fluorescence microscopy of optically cleared spheroids
Spheroids were fixed in formalin (Sigma, #HT5014) overnight, then washed twice with PBS and incubated with propidium iodide (10 µg/ml) (Molecular probes #11599296) in the presence of RNase (1 mg/ml) for 30 min (Euromedex #9707). Spheroids were then embedded in 1% low-melting agarose in PBS (Euromedex #1670). Agarose cylinders containing spheroids were collected with a biopsy puncher (8 mm in diameter) and sequentially transferred to 25% (2 h and then overnight), 50% (2 h twice), 70% (2 h twice) and 95% (2 h and then overnight)(v/v) ethanol solutions for complete dehydration. For clearing, samples were transferred in BABB solution (1:2 benzyl alcohol (Alfa Aesar#41218): benzyl benzoate (Sigma#B6630)) for 8 h and then overnight. Images were acquired as previously described15. Propidium iodide fluorescence was excited with a 532 nm laser and detected with a 593 nm long-pass filter. The voxel size was 0.645 × 0.645 × 1 μm.
Global spheroid analysis
The Amira software (Mercury Computer Systems Inc., Chelmsford, MA) was used to create iso-surfaces from the LSFM z-stacks by fluorescence intensity thresholding, and to perform morphometric measurements that were used to determine the spheroid volume and flatness. The same threshold was used for D6-500 and D2-5000 spheroids.
Atomic force microscopy mechanical measurements and data analysis
PDMS micro-well arrays (see Supplementary Fig. S2) coated with Pluronic-F127 (Sigma, #P2443) to prevent cell adhesion27 were fixed to the glass bottom of a Petri dish (FluoroDish WPI#50-823-005, Sarasota, USA) using an oxygen plasma torch (Elveflow, Paris, France). The Petri dish was then filled with 4 ml of culture medium before adding one spheroid in each micro-well using a micropipette. D2-5000 and D6-500 spheroids were placed in different arrays inside the Petri dish that was then carefully placed on the stage of the AFM (Nanowizard II, JPK Instruments, Berlin, Germany) mounted on an inverted microscope (Zeiss, Germany). This setup is fitted with a Petri dish heater (JPK) set to 37 °C and under a flow of 5% CO2 to maintain the physiological conditions during the measurements. The deflection sensitivity of the MLCT cantilever (Bruker, Germany) was obtained by calculating the force-distance curve on the glass bottom of the Petri dish 30 min after placing the cantilever in the liquid medium to allow the cantilever to reach the thermal equilibrium. The thermal tune method available for the AFM system was used to calibrate the spring constant of the cantilever far from the surface. The calibrated spring constants were 0.13–0.16 N/m. The “force mapping” mode was used to calculate the force-distance curves over 100 µm2 zones on top of each spheroid. The maximum applied force was kept at 1 nN during force mapping and for the initial approach. The JPK Data analysis software was used to extract the apparent Young’s modulus form each force curve. Each approach curve was first smoothed using a 3 pixels Gaussian filter, and then force vs. vertical deflection curves were converted into force vs. tip separation curves before fitting the Conical Hertz Sneddon model:
where F is the Force, E is the apparent Young’s modulus, α is the cantilever tip half angle, 17.5° for MLCT probes, ν is the Poisson ratio set to 0.5 in liquid and δ is the indentation depth.
Estimation of the stored growth induced-stress using mathematical modeling
The mathematical model that describes the stored growth-induced stress and its effect on spheroid opening upon incision has been described in19 and we recall here the key points. The elastic model is hyperelasticity, and we used a Ciarlet-Geymonat material with a Poisson coefficient ν = 0.46 and Ciarlet-Geymonat parameter a′ = 0.4. The stored stress distribution is assumed to have a spherical symmetry. It was proved that radial and tangential stored stresses are linked, and they are defined by a magnitude and a radial profile. The radial profile is assumed to follow a power law with exponent n. To estimate the value of the total radial stored stress and its standard deviation, series of simulations were performed for various magnitudes of stored stress (see Supplementary Fig. S2). To compare the model response and the experimental data (opening/diameter versus incision depth/diameter), for each value γ of the magnitude of stored stress, the number of data points below the response curve gives the fraction of data points that correspond to a stored stress below the value γ. This allows sampling the cumulative distribution function (cdf) of the stored stress magnitude. Fitting the cdf of a Gaussian distribution to these points provides the values of stored stress and the standard deviation (see Supplementary Fig. S2).
Statistical analysis
Graphs and data were analyzed with GraphPad Prism version 6.00 (GraphPad software, La Jolla California USA, www.graphpad.com) and R (R Core Team 2017, https://www.R-project.org/). The non-parametric Mann-Whitney test was used to compare data from different conditions. Stacks were analyzed using the Amira, Imaris and Fiji28 software programs.
References
Fung, Y. C. What are the residual stresses doing in our blood vessels? Annals of biomedical engineering 19, 237–249 (1991).
Chuong, C.-J. & Fung, Y.-C. Residual stress in arteries, in Frontiers in biomechanics 117–129 (Springer, 1986).
Liu, S. Q. & Fung, Y. C. Zero-stress states of arteries. J Biomech Eng 110, 82–84 (1988).
Omens, J. H. & Fung, Y. C. Residual strain in rat left ventricle. Circulation research 66, 37–45 (1990).
Xu, G., Bayly, P. V. & Taber, L. A. Residual stress in the adult mouse brain. Biomechanics and modeling in mechanobiology 8, 253–262, https://doi.org/10.1007/s10237-008-0131-4 (2009).
Correia, A. L. & Bissell, M. J. The tumor microenvironment is a dominant force in multidrug resistance. Drug Resist Updat 15, 39–49, https://doi.org/10.1016/j.drup.2012.01.006 (2012).
Jain, R. K., Martin, J. D. & Stylianopoulos, T. The role of mechanical forces in tumor growth and therapy. Annual review of biomedical engineering 16, 321–346, https://doi.org/10.1146/annurev-bioeng-071813-105259 (2014).
Stylianopoulos, T. et al. Causes, consequences, and remedies for growth-induced solid stress in murine and human tumors. Proc Natl Acad Sci USA 109, 15101–15108, https://doi.org/10.1073/pnas.1213353109 (2012).
Hirschhaeuser, F. et al. Multicellular tumor spheroids: an underestimated tool is catching up again. Journal of biotechnology 148, 3–15, https://doi.org/10.1016/j.jbiotec.2010.01.012 (2010).
Laurent, J. et al. Multicellular tumor spheroid models to explore cell cycle checkpoints in 3D. BMC Cancer 13 (2013).
Nath, S. & Devi, G. R. Three-dimensional culture systems in cancer research: Focus on tumor spheroid model. Pharmacology & Therapeutics 163, 94–108, https://doi.org/10.1016/j.pharmthera.2016.03.013 (2016).
Sant, S. & Johnston, P. A. The production of 3D tumor spheroids for cancer drug discovery. Drug Discovery Today: Technologies 23, 27–36, https://doi.org/10.1016/j.ddtec.2017.03.002 (2017).
Weiswald, L.-B., Bellet, D. & Dangles-Marie, V. Spherical Cancer Models in Tumor Biology. Neoplasia 17, 1–15, https://doi.org/10.1016/j.neo.2014.12.004 (2015).
Costa, E. C. et al. 3D tumor spheroids: an overview on the tools and techniques used for their analysis. Biotechnol Adv 34, 1427–1441, https://doi.org/10.1016/j.biotechadv.2016.11.002 (2016).
Desmaison, A. et al. Impact of physical confinement on nuclei geometry and cell division dynamics in 3D spheroids. Scientific reports 8, 8785, https://doi.org/10.1038/s41598-018-27060-6 (2018).
Gomes, A. et al. Oxygen Partial Pressure Is a Rate-Limiting Parameter for Cell Proliferation in 3D Spheroids Grown in Physioxic Culture Condition. PLoS One 11, e0161239, https://doi.org/10.1371/journal.pone.0161239 (2016).
Gonzalez-Rodriguez, D., Guevorkian, K., Douezan, S. & Brochard-Wyart, F. Soft matter models of developing tissues and tumors. Science 338, 910–917, https://doi.org/10.1126/science.1226418 (2012).
Dolega, M. E. et al. Cell-like pressure sensors reveal increase of mechanical stress towards the core of multicellular spheroids under compression. Nature communications 8, 14056, https://doi.org/10.1038/ncomms14056 (2017).
Colin, T. et al. Experimental estimation of stored stress within spherical microtissues. Journal of mathematical biology, 1–20 (2018).
Pillet, F., Gibot, L., Madi, M., Rols, M. & Dague, E. Importance of endogenous extracellular matrix in biomechanical properties of human skin model. Biofabrication 9, 025017 (2017).
Jaiswal, D. et al. Stiffness analysis of 3D spheroids using microtweezers. PLoS One 12, e0188346, https://doi.org/10.1371/journal.pone.0188346 (2017).
Goodman, T. T., Olive, P. L. & Pun, S. H. Increased nanoparticle penetration in collagenase-treated multicellular spheroids. International journal of nanomedicine 2, 265–274 (2007).
Baxter, L. T. & Jain, R. K. Transport of fluid and macromolecules in tumors. I. Role of interstitial pressure and convection. Microvasc Res 37, 77–104 (1989).
Ong, C. S. et al. In vivo therapeutic applications of cell spheroids. Biotechnology Advances 36, 494–505, https://doi.org/10.1016/j.biotechadv.2018.02.003 (2018).
Ivascu, A. & Kubbies, M. Rapid generation of single-tumor spheroids for high-throughput cell function and toxicity analysis. Journal of biomolecular screening 11, 922–932, https://doi.org/10.1177/1087057106292763 (2006).
Schneider, C. A., Rasband, W. S. & Eliceiri, K. W. NIH Image to ImageJ: 25 years of image analysis. Nat Methods 9, 671–675 (2012).
Aoun, L. et al. Microdevice arrays of high aspect ratio poly(dimethylsiloxane) pillars for the investigation of multicellular tumour spheroid mechanical properties. Lab on a chip 14, 2344–2353, https://doi.org/10.1039/c4lc00197d (2014).
Schindelin, J. et al. Fiji: an open-source platform for biological-image analysis. Nat Methods 9, 676–682 (2012).
Acknowledgements
We thank the members of our groups for discussions and interest in this project. The authors wish to acknowledge the TRI-Genotoul, the electron microscopy (CMEAB) and photonic microscopy ITAV facilities. The authors thank Elisabetta Andermarcher for expert manuscript editing. This work was supported by the CNRS, Université Paul Sabatier, Région Midi-Pyrénées, la Ligue Nationale Contre le Cancer (comité de la Haute-Garonne) and ITMO Cancer AVIESAN (Alliance Nationale pour les Sciences de la Vie et de la Santé, National Alliance for Life Sciences & Health) within the framework of the Cancer Plan.
Author information
Authors and Affiliations
Contributions
L.G., B.D. and V.L. conceived the experiments. L.G., L.R. and C.S. conducted the experiments. J.F. conceived and developed the mathematical model. L.G., B.D. and V.L. analyzed the results. L.G., B.D. and V.L. wrote the manuscript. All authors reviewed the manuscript.
Corresponding author
Ethics declarations
Competing Interests
The authors declare no competing interests.
Additional information
Publisher’s note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Guillaume, L., Rigal, L., Fehrenbach, J. et al. Characterization of the physical properties of tumor-derived spheroids reveals critical insights for pre-clinical studies. Sci Rep 9, 6597 (2019). https://doi.org/10.1038/s41598-019-43090-0
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-019-43090-0
- Springer Nature Limited
This article is cited by
-
Mechanical deformation and death of circulating tumor cells in the bloodstream
Cancer and Metastasis Reviews (2024)
-
Minimal Morphoelastic Models of Solid Tumour Spheroids: A Tutorial
Bulletin of Mathematical Biology (2023)
-
Designing and interpreting 4D tumour spheroid experiments
Communications Biology (2022)
-
Mechanical properties of cell sheets and spheroids: the link between single cells and complex tissues
Biophysical Reviews (2021)
-
A synergic approach to enhance long-term culture and manipulation of MiaPaCa-2 pancreatic cancer spheroids
Scientific Reports (2020)