Abstract
Numerous studies have explored the biomechanics and energetics of human walking, offering valuable insights into how we walk. However, prior studies focused on changing external factors (e.g., walking speed) and examined group averages and trends rather than individual adaptations in the presence of internal constraints (e.g., injury-related muscle weakness). To address this gap, this paper presents an open dataset of human walking biomechanics and energetics collected from 21 neurotypical young adults. To investigate the effects of internal constraints (reduced joint range of motion), the participants are both the control group (free walking) and the intervention group (constrained walking - left knee fully extended using a passive orthosis). Each subject walked on a dual-belt treadmill at three speeds (0.4, 0.8, and 1.1 m/s) and five step frequencies ( − 10% to 20% of their preferred frequency) for a total of 30 test conditions. The dataset includes raw and segmented data featuring ground reaction forces, joint motion, muscle activity, and metabolic data. Additionally, a sample code is provided for basic data manipulation and visualisation.
Similar content being viewed by others
Background & Summary
Gait analysis is an essential tool for understanding human walking. Previous studies have demonstrated that humans optimise their gait, but the optimisation criteria may vary with individual health status and environmental conditions. Neurotypical adults tend to walk efficiently1,2,3 as predicted by simple pendulum models4,5,6,7. This is a consequence of the adaptations they make when walking at different speeds8,9,10,11,12,13, in the presence of changing external conditions14,15,16,17, and as they age13,18,19,20,21,22,23. Similar can be seen in people with physical impairments as they also adapt their gait24,25,26,27,28,29 albeit for different reasons than neurotypical individuals30,31,32,33,34. However, little is known about human adaptations on an individual level for several reasons. First, human studies are resource-intensive to conduct, making access to much-needed data severely limited (particularly for neurologically-impaired patients). Furthermore, the findings cited above come from studies designed-for-purpose and not publicly shared. Second, studies seldom investigate the effects of constraining normally available gait mechanisms (internal constraints; e.g., reducing muscle strength). One recent study that did35 has a small sample size and a small number of walking conditions tested (in terms of gait speed and gait cycles), limiting the analysis and outputs. Instead, these studies focus on imposing external constraints (e.g., walking speed36,37 and spatiotemporal parameters3,38). This is also the case with publicly available datasets9,10,39,40,41,42,43,44. Third, sex, age, and/or speed-matching, common in comparing gait across diverse cohorts37,45, is limited to group averages and trend comparisons. Consequently, an understanding of person-specific adaptations coming from individual biomechanical features is lacking.
Our study was designed to address these gaps and provide insights into individual gait adaptations when walking with internal constraints. A group of 21 neurotypical young adults (30 ± 8 years) was recruited for the study conducted in the CAREN biomechanics lab (Motek Medical B.V., the Netherlands) at The University of Melbourne, Australia. Neurotypical participants were chosen instead of neurologically impaired for two reasons. First, the demands of the study are too large for a patient group, and it would be unethical to impose further constraints on their restrained physical ability. Second, similar trends in neurotypical and impaired gait24,25,33,34 provide evidence that the underlying neuromusculoskeletal mechanisms governing human walking do not get overridden but simply change their manifestation in the presence of neurologically originated physical impairment. This suggests that insights gained from studying neurotypical populations could potentially be used to better understand patient walking as well, provided a cautious and informed approach is taken in translating the findings.
To allow the translation of the study findings into a better understanding of patient walking, the study was designed in discussion with experienced physiotherapists from two clinics in Melbourne. As a result, participants walked at two speeds relevant to hemiparetic patients (0.4 and 0.8 m/s) and one common in the neurotypical population (1.1 m/s). Preliminary tests showed that locking the knee joint using passive orthosis is most likely to simulate hemiparetic conditions and produce hip hiking (‘unaffected frontal hip/pelvic angle when the affected limb is in mid-swing,’46), circumduction (‘greater-than-normal frontal thigh angle during mid-swing of the affected leg,’46), and step-to-walking (a gait where ‘toe of the affected side does not pass the toe of the non-affected side in the stance phase’,47), all common compensations in hemiparetic patients. This was demonstrated in our preliminary study in two participants48. The participants walked at five step frequencies (from − 10% to +20% of their preferred cadence) per speed since changing step length and time impacts both neurotypical and patient walking. The protocol was spread across three days/sessions to minimise fatigue and make the study technically and resource-wise feasible. Finally, to avoid problems of comparing data across different study designs, four different types of data relevant to characterise human walking was collected: ground reaction forces through a dual-belt instrumented treadmill, joint movements using marker-based motion capture system, muscle activations using surface electromyography, and metabolic cost using a portable indirect calorimetry device (see Fig. 1).
In summary, the unique features of the presented dataset, publicly available on figshare49 include:
-
comprehensive measurement data – our dataset contains four different types of data that have commonly been used in characterising human walking: joint kinematics, ground reaction forces, muscle activity, and metabolic cost data, a combination rarely available in other studies;
-
hundreds of strides per condition – unlike many datasets that only contain several strides per condition, our dataset contains 5-min worth of strides per condition, allowing analysis of gait parameter acclimatisation (and plateauing) over time as well50;
-
internal constraints – in addition to studying the effects on gait of changing external constraints (cadence, walking speed), our dataset also imposes internal constraints (limited joint angle), providing insights into how (through recorded adaptations) and why (through metabolic, energetic, and biomechanical variables) humans walk the way they do in tested conditions/environments; and
-
individual level adaptations – unlike studies that speed/age/sex-match their control and intervention groups and are thus limited to trends and group averages, our dataset allows studying individual adaptations across many different conditions.
Methods
Participants
Neurotypical adults were invited to participate in the study through a public advertisement made available on the official website of the Human Robotics Research Group of The University of Melbourne, Australia. The advertisement described the study goal, protocol, and duration and provided communication channels for those interested in knowing more and/or joining the study. The interested participants were interviewed and formally recruited if they met a set of inclusion/exclusion criteria. Inclusion criteria were (i) neurotypical young persons with no known lower limb impairments, (ii) 18-60 years old, (iii) 1.55-1.90 m tall, and (iv) weighing between 50-90 kg. Exclusion criteria were (i) significant trauma to the lower limbs and/or orthopedic procedures in the last six months, (ii) any form of diagnosed gait abnormalities and/or walking problems, (iii) cognitive and/or communicative problems affecting the ability to comprehend or follow instructions, and (iv) any other pain conditions.
Following this, 21 neurotypical young adults (5 females, 30 ± 8 years, body mass 72.7 ± 12.3 kg, height 1.72 ± 0.09 m, BMI 24.5 ± 2.7 kg/m2, mean ± standard deviation) participated in the study. Of those, 19 completed the entire protocol, and two dropped out after two out of three sessions (their data are also available with the manuscript). The anthropometric details of all the participants are summarised in Table 1. Only one participant (Sub3) had previous experience walking with a lower limb orthosis, albeit in a different study. All participants were provided a detailed plain language statement and signed the informed consent form that included a clause on agreeing to use pictures/videos in data dissemination. The ethics committee of The University of Melbourne approved the study (2021-20623-13486-3).
Experimental conditions
The experimental study was designed around three multidimensional factors: walking speed, step frequency (i.e., cadence), and physical constraint. Walking speed came in three levels, including slow (v1 = 0.4 m/s), medium (v2 = 0.8 m/s), and normal (v3 = 1.1 m/s). Step frequency came in five different levels, including preferred (f3), two lower (f1 = 0.9f3 and f2 = 0.95f3), and two higher (f4 = 1.1f3 and f5 = 1.2f3) levels. Finally, physical constraint came in two levels, including a condition without restrictions on the lower limbs (c1) and one with a unilateral knee orthosis (c2, shown in Fig. 1). The orthosis was always worn on the left side with the intention of locking the participants’ knee joint in full extension. Each participant underwent all 30 combinations of the three factors (3 × 5 × 2) spread over two data collection sessions (see next section for details). Table 2 gives an overview of the naming convention used in the data analysis (and found in the dataset shared on figshare). The choice to go with asymmetric step frequency above and below the preferred one was made after preliminary testing showed that 0.8f3 (i.e., − 20%) at slow speed leads to highly imbalanced and potentially dangerous walking. As mentioned, all testing was done on a dual-belt instrumented treadmill in the Motek CAREN lab installed at the biomechanics lab at The University of Melbourne.
Experimental protocol
The study was organised into sessions, bouts, and conditions in the specified order of complexity. The participants were asked to come into the lab on three different days, each corresponding to one session. The first session (Ses1) served as a preparation and familiarisation day, while the second (Ses2) and third (Ses3) sessions were data collection days.
The two data collection sessions were organised into 3 bouts each, with bouts differing in a unique vi − cj speed-constraint factor combination. A bout consisted of 5 walking conditions executed at the same walking speed with no breaks in between. With that, each participant underwent 15 (half) walking conditions per session, reducing the potential impact of fatigue while still collecting large amounts of data. The order of the cadence factor levels (i.e., f1 to f5) within a single vi − cj speed-constraint factor combination (bout) was always randomised. On the other hand, the order and distribution across sessions of bouts were only partially randomised to avoid familiarisation effects. For example, multiple occurrences of the speed (e.g., v1 − v3 − v1) or consecutive occurrences of the impairment factor (e.g., c1 − c2 − c2) within a single session were rejected, reducing the number of randomisation outcomes. This was further extended by the requirement to avoid the order-of-speed bias, leading to a uniquely determined choice of the speed-constraint factor combinations available to choose from. Fig. 2 gives an example of the conditions randomisation for a single participant.
Preparatory session (Ses1)
The first session served as a study familiarisation and baseline day. The participants started by walking at 1.1 m/s and preferred cadence for six minutes50 (Fig. 3, top - Part 1). The preferred cadence was estimated during the last 15 seconds of that period using a simple script that counts heel strikes in real-time. This number was then used to guide two subsequent 2-minute exploration periods at the same speed. During the first 30 seconds of each exploration period, a metronome guided participants 20% higher or lower from their previously estimated preferred cadence in a randomised order. The participants were then allowed to go back to their preferred cadence for the remaining 90 seconds in each 2-minute period. The same was repeated at 0.4 and 0.8 m/s walking speeds in a randomised order, albeit with a shorter, 3-minute familiarisation period (as opposed to a 6-minute period at 1.1 m/s). This allowed the calculation of preferred cadences based on three experimentally measured values51. The preferred cadence at each speed, calculated as an average of the three measured values, is given in Table 3.
The participants were then instructed to find their preferred walking speed using the staircase method52,53. In short, the treadmill speed was twice increased from 0.5 m/s and decreased from 1.6 m/s in 0.1 m/s increments (every 10 seconds), until participants identified their preferred speed. The initially identified value was fine-tuned by changing the speed in 0.05 m/s increments up or down until the person settled into the final value for that segment. This speed was noted 4x and averaged to obtain the final preferred speed. This was followed by a 7-minute walking test at that preferred speed, similar to the tests at the other three speeds as described above, with the aim of finding the preferred cadence at the participant’s preferred speed.
The process of finding each person’s preferred step frequency (cadence) at each of the three speeds was subsequently repeated while wearing the orthosis (Fig. 3, top - Part 2). Similarly, the preferred cadence was estimated during the last 15 seconds of three subsequent periods using a simple script. The main difference between the free (Part 1) and constrained (Part 2) walking parts lies in how a preferred speed is found. Unlike the staircase method used during free walking, a simple increase in the treadmill speed until participants provided an auditory cue was used during constrained walking. This is because constrained preferred speed is not used in data collection sessions, thus making finding its precise value less critical. The main reason for still finding the preferred speed during constrained walking was to allow participants to familiarise themselves with the orthosis by giving them more time to walk with it. Once the self-selected speed was identified, which usually took a couple of minutes, all participants were given 20 minutes of walking with the orthosis at the identified speed, split into two 10-minute walking periods at the start and end of Part 2 (see Fig. 3).
Data collection session (Ses2/Ses3)
During the two data collection sessions, participants walked across three speed-constraint factor combinations (i.e., bouts), each taking 25 minutes (Fig. 3, bottom). Without a break in between different cadences (1 cadence = 1 test = 5 min), each bout had speed and impairment fixed while sweeping through all five step frequencies (f1 to f5) in a randomised order. A metronome guided participants to ensure the desired step frequency, a practice shown not to affect the metabolic cost (MC)51. The test length of 5 minutes is based on a previous study that demonstrated that it takes about 3 minutes for participants to reach 95% of their metabolic steady-state3, leaving two minutes’ worth of data for averaging (one in a more conservative case).
The three bouts were separated by a 5-10 minute break and another 5 minutes to measure resting metabolic cost while standing. In total, the resting MC was measured five times throughout each session to capture a potential increase in resting energetic demands as the session proceeds and thus validate the metabolic-level fatigue effects. The effects of potentially accumulating fatigue were also measured using EMG amplitude signal (in addition to MC) during walking at a preferred speed, a 6-minute test repeated at the start and end of each session. The former (i.e., muscle-level fatigue) can be validated using different methods in both time and frequency domains54.
In terms of the equipment, participants were fitted at the start of each data collection session with retroreflective markers that capture their lower limbs (and in some cases, upper body) movement in space, wireless surface electromyography (EMG) to measure their EMG amplitude (an estimate of muscle activity), and a portable indirect calorimetry system to measure their energy use. An experienced postdoctoral researcher, trained in placing the equipment and having previously led two human studies, put all sensors and markers on for all participants. The first 6-minute walk at the preferred speed served as a warm-up trial50 and to control the potential fatigue effects. The test was immediately followed by ten repeated motions of sitting down and standing up (about knee height chair), and two passes up and down a flight of 15 stairs. The muscle activity measured during these two tests and a 6-minute walking can be used in finding a muscle activity normalisation factor55 (see later sections for more details).
Participants were asked to comply with the following before coming into the lab: (i) no strenuous exercise at least 12 hours, preferably 24 hours before coming into the lab, (ii) no alcohol, caffeine, or nicotine in the period of 4 hours before the session start, and (iii) large meal no later than 1.5 hours before coming into the lab. Participants were only allowed to drink water during the session, and no food was permitted.
Walking speeds
The normal walking speed was initially set to 1.25 m/s as this speed is commonly used in tests with healthy participants56,57,58,59,60 and is considered the preferred average walking speed in young adults9,13. However, walking with the orthosis at that speed and +20% step frequency proved to be potentially dangerous for the participants, so a decision was made to reduce this to 1.1 m/s.
The other two speeds were chosen to facilitate healthy-patients walking comparison, acknowledging that differences between the two groups go beyond simply speed-matching their gaits. The 0.8 m/s is considered a lower boundary of the so-called community ambulator category61 and is typical of high-functioning hemiparetic patients25,29,34,62. The 0.4 m/s is considered an upper boundary of the so-called household ambulator category61 and is typical of low-functioning hemiparetic patients25,63,64.
Unilateral knee orthosis
A simple, in-house designed orthosis/brace was used to lock the knee joint and elicit compensatory movements during walking (Fig. 4a). The orthosis consists of two 3D-printed cuffs and two metal bars with a double-hinge joint connecting the cuffs. The cuffs are based on a 3D model of several human legs obtained using a 3D scanner and imported into 3D modelling software. The cuffs come in several sizes to account for variations in the participants’ legs. Furthermore, the design allows changing the cuffs’ relative position with respect to the knee joint to provide a better fit and comfort.
For consistency, participants always wore the orthosis on their left leg (Fig. 4b,c). To allow the placement of retroreflective markers for the motion capture system and EMG sensors, cuffs come with multiple cut-outs. The cuffs were secured in place by four BOA straps in total, two on each cuff. A double-hinge system allows adjusting the orthosis to different leg sizes and changing the fixed knee angle. In this study, the fixed knee angle was set by locking the hinge when a participant was standing with their knee fully extended, rendering a zero biological knee angle in a static pose. During experiments (i.e., dynamic movements), the compliant tissue in human legs inevitably allows a small amount of knee flexion in the swing phase of gait. As a consequence, the effective knee flexion during walking was always higher than zero (up to 20° in the swing in some participants). The orthotic movement did not cause any discomfort or pain to participants, likely due to the soft padding lined on the cuff’s inner side.
Data collection and processing
Four categories of data were collected in the study: lower limb kinematics using a marker-based motion capture system (in the case of half of the participants also upper limb, see Table 4), ground reaction forces (GRF) using a force-instrumented dual-belt treadmill, an estimate of muscle activation using wireless surface electromyography (EMG) sensors, and the metabolic cost of walking using indirect calorimetry. All data processing was done using custom-written scripts in Matlab 2021a (Mathworks, Massachusetts, USA).
Kinematics and forces data
Gait data was collected in the Motek CAREN (Motek Medical B.V., the Netherlands) lab environment using a dual-belt instrumented treadmill and Vicon motion capture system with 10 cameras (Vicon Motion Systems, Oxford, UK). The marker data was collected at 100 Hz, and force data (GRF) at 1 kHz. Participants were fitted with a custom set of 26 retroreflective markers (spherical, 14 mm diameter, B&L Engineering, CA, USA) bilaterally placed in the pelvic area and on lower limbs. Of the 26 markers used, 23 are functional following65, and the remaining three are added to allow differentiating the two legs through asymmetric marker patterns. Half the participants also agreed to have markers placed on their torso and arms, in which case a custom set of 11 markers was used (Fig. 5a,b). It should be noted that while 26 lower limb and 11 upper limb markers were the default marker configuration, some participants had 24 lower limb markers and 9 upper limb markers, with two auxiliary markers missing in both cases. This was the case with a few early participants and is indicated in Table 4. The two missing markers include LTIBaux2 and RTIBaux2 in the case of lower and RArmWristAux in the case of the upper limb.
Data were segmented into steps using a 5% GRF signal threshold (i.e., for a 70 kg person, the threshold is 70 ⋅ 9.81 ⋅ 0.05 = 34N), as this was the lowest threshold across all participants that had a negligible amount of false positives. False positives occur when the force oscillates around the defined threshold, resulting in, e.g., multiple heel strikes detected in a single step. The provided gait segmentation algorithm comes with a code for the automated correction of false positives. The code also corrects for the missing steps, which occur when a person steps on the opposite belt (i.e., left leg on the right belt, called overstepping). Segmented and corrected data were subsequently time-normalised to 0-100% using linear interpolation, with the step defined as heel strike to subsequent heel strike. The number of detected steps on each side (and consequently, the number of heel-strike and toe-off events) is not necessarily equal in the raw data and was thus corrected in post-processing for the simplicity of the subsequent analysis. Furthermore, the steps were removed if/where needed at the start/end of a dataset (i.e., a 5-minute test) to ensure every dataset starts with the left and ends with the right step (again, for the analysis’ simplicity).
The marker data were filtered using a 4th-order zero-lag Butterworth filter with a 6 Hz cut-off frequency9. Filtered marker coordinates in 3D space of lower limbs were used to calculate joint angles (ankle, knee, hip, and pelvis) in the sagittal plane as per Research Methods in Biomechanics66 and following ISB (International Society of Biomechanics) guidelines67. Torso markers are only available for half the participants but do not allow for a similar calculation of the upper limb joint angles – their purpose was to capture arm swing movements and chest movements rather than upper limb joint angles. The chest movement is particularly useful in calculating, e.g., Lyapunov stability index52,68, an increasingly relevant index in the patient population. A standing static calibration trial was performed at the start of each session to build a marker template and define offset joint angles. These angles capture imperfections in placing markers (e.g., a measured 1° knee flexion despite the person standing with their knees fully extended) and were subtracted from dynamic movement to obtain a true measurement of the joint angle (i.e., walking ROM) rather than errors in marker placement. During the static trial, participants were instructed to stand still, hip-width apart with straight knees and back and feet parallel with toes facing forward, as seen in Fig. 5c66. Study investigators demonstrated this position to each participant and ensured they followed the instructions. Once calculated for the entire test, kinematic data were segmented into gait cycles using heel strike and toe-off event indices determined using GRF signal.
EMG amplitude data
The EMG amplitude was measured in eight muscles per leg using surface electromyography (sEMG) Delsys Trigno (Delsys Inc., Natick, MA, USA) system. The raw data signal, captured at 2 kHz, was read by the Vicon PC running Nexus 2.8 via cable connection for data synchronisation purposes. For participants S1-12, the connection was done using a USB cable (trigger not available), which Delsys claims results in a synchronisation error of ± 20 ms on average (in our experience, the variations can significantly exceed this estimate). For participants S13-21, a trigger was available to ensure no-delay synchronisation. NOTE: The delay was corrected in participants S1-12 in post-processing by cross-correlating accelerometer data from the Right Tibialis Anterior EMG/IMU sensor with accelerations from RTibExt marker data, a method validated on the synchronised data from participants S13-21. The correction (in ms) for each participant is given in Supplementary File, Table S1. A validation of this approach for correcting delay is demonstrated in Supplementary File, Fig. S1.
The wireless Trigno Avanti sensors were placed in line with muscle fibers69 over the Tibialis Anterior (TibAnt), Gastrocnemius Lateralis (GastroLat) and Medialis (GastroMed), Vastus Lateralis (VastLat) and Rectus Femoris (RecFem), Biceps Femoris (BicFem) and Semitendinosus (Semitend), and Gluteus Maximus (GlutMax) muscles (Fig. 4a,b). The same order of muscles is preserved in raw files provided with the dataset, with muscles 1-8 (EMG sensors 1-8) corresponding to the left leg and 9-16 (EMG sensors 9-16) to the right leg. NOTE: Data are organised per muscle name and not per sensor name.) Each participant’s skin was prepared following the SENIAM guidelines (website, 2023). This included shaving the hair in the spots of the sensor placement, as well as cleaning the skin with alcohol and ensuring it was dry before the sensors were attached.
The processing of the raw EMG data started by detecting a linear envelope. This was done using a band-pass filter (10-500 Hz, implemented on the Trigno sensors) followed by a full-wave rectification and smoothening (a 100 ms moving average window). Linear-envelope data were normalised using pooled EMG activity collected during stair climbing, sit-to-stand activity, and baseline walking test at the start of each session. Maximal muscle activity was determined in each muscle per person per activity, and the highest value across the three tests per muscle was used as a normalisation factor (see Table S2 in Supplementary File). The reason for not using Maximal Voluntary Isometric Contraction (MVIC) tests was the lack of necessary equipment to correctly measure maximum EMG amplitude and to avoid major drawbacks of the isometric contraction approaches55,70, including inconsistent maximal contractions and inability to volitionally contract specific muscles. The activity-based method used herein also has the benefit of ensuring normalised muscle activity to be between 0 and 1 (muscles are generally more active in stair climbing and sit-to-stand movement than walking), which is a prerequisite for using these data in driving musculoskeletal models (e.g., OpenSim). Other ramifications of this approach can be found in the section Usage Notes. Muscle activity data were segmented into gait cycles using heel strike and toe-off event indices determined using GRF signal. Additionally, a signal-to-noise (SNR) ratio, calculated as 20 ⋅ log10(signalrms/noiserms), is provided for each muscle across all gait cycles (similar to segmented EMG amplitude). Observed noise levels were predominantly in the ( − 5, 5)μV and ( − 3, 3)μVrms range, so the latter is used in the provided SNR calculations. Whenever SNR > 6 dB, which corresponds to the RMS amplitude of the actual EMG signal that is more than twice the RMS amplitude of the noise, the signal is considered good. NOTE: Normalisation factors of each activity (walking, stair climbing, and sit-to-stand) can be extracted and used separately from the provided raw EMG data of walking, stair climbing, and sit-to-stand activity.
Metabolic data
Respiratory O2 consumption and CO2 production were collected using PNOE indirect calorimetry system (Endo Medical, Palo Alto, US), consisting of an appropriate face mask and a portable measurement unit worn on the back. The masks come in different sizes to accommodate different participants and minimise the exchanged gas leakage. The data of the last minute of both 5-minute resting (standing still) and 5-minute walking tests were used to calculate the energy consumption using the simplified Brockway formula71. Net MC of walking (in W/kg) was then calculated by subtracting the resting value measured before each bout from all 5-minute tests within that bout and dividing by the participant’s mass. This was done to avoid the effect of potentially accumulating fatigue reflecting in the net energetic cost of the tests later in the session. Furthermore, the metabolic cost of transport (in J/kgm) was calculated by dividing the normalised MC by the walking speed. NOTE: Resting MC throughout each session is provided with the dataset.
Data Records
The full dataset is available on figshare49. Since figshare repository does not allow folder structure at the time of submission, all data are uploaded as .zip files, grouped according to the content organisation depicted in (Fig. 6 and Table 5). More details are provided in the subsequent sections. Where possible, the same naming and data structure conventions are maintained across different data groups for consistency.
Raw data
CONTAINS: ground reaction force (GRF) and the feet centre of pressure (CoP) data; the 3D position of all the markers; muscle activity (EMG) data for each of the sixteen muscles; and metabolic cost (MC) data as exported by the metabolic analyser.
DESCRIPTION: Raw data are stored in .csv, .c3d, and .mat formats, all widely used and accepted file formats. The CSV format is a text format that can be read by any text file reader, including Microsoft Excel and Matlab. This is arguably the format that will reach the largest user base. The C3D format is typically used in the biomechanics community, but since it’s a binary format, it requires extra steps and processing before it can be accessed. Finally, raw data are also provided in MAT format that can be easily read in Matlab and Python, the two most commonly used programming languages in the research community. Where necessary, raw data files in CSV and MAT formats were pre-processed to, e.g., remove data from a 5-min test if the participant had to stop to fix a marker or reduce GRF frequency from 2 kHz to 1 kHz (an artifact of the originally collected GRF data frequency).
The RawData on Level 1 are organised into three groups: CSV, C3D and MAT, corresponding to the format the data are saved in. Within each group, data are separated per participant on Level 2, resulting in 21 sub-groups in each CSV, C3D, and MAT group. The data files available for download from figshare reside on Level 3 as .zip files. When downloaded and opened, the fields from Levels 4-7 will become available for further analysis and manipulation. In particular:
-
.csv – files available for download are called, e.g., RAW_csv_Sub17.zip. Within this file, data are separated into four folders, corresponding to Kinematics, Kinetics, EMG, and MC. The Kinematics folder contains one CSV static calibration file per session, CSV files of all 30 tests (T1-T30), and two CSV files per session of preferred walking (at the start and end). Similar files can be found in the Kinetics and EMG folders, with the addition of CSV files for stair negotiation and sit-to-stand in the latter. The MC folder, on the other hand, contains three CSV files per session of 25-minute bouts, five CSV files per session of resting, and two CSV files per session of preferred walking. The file naming convention concatenates participant identification, type of data, test number, and session number where applicable. For example, marker data of S6 in T16 is located in Kinematics folder under name Sub6_Kinematics_T16.csv and will become available once the RAW_csv_Sub6.zip is opened. Similarly, MC data of S6 in Bout2 of Session2 is located in MC folder under name Sub6_MC_Bout2_Session2.csv.
-
.c3d – files available for download are called, e.g., RAW_c3d_Sub5.zip. Since data are saved into a single C3D file per test, the names within the zip file are concatenated subject identification (e.g., Sub5) and test name (e.g., T17). For example, the raw data of S5 and test T17 is called Sub5_T17.c3d and will become available once the RAW_c3d_Sub5.zip file is opened. Apart from the C3D files of all 30 tests (T1-T30), each subject-specific folder also contains C3D files of static calibration (one per session) and preferred walking trials (two per session, one at the start and one at the end).
-
.mat – files available for download are called, e.g., RAW_mat_Sub13.zip. To avoid too large file sizes, GRF, CoP, and markers data are grouped into Mechanics, and EMG and breath data into Energetics. The subsequent level in the tree structure is test names, followed by one of the data groups. For example, raw GRF data of S4 in test T16 is saved in Sub4_rawMechanics.mat, which will become available once RAW_mat_Sub4.zip is opened. Similarly, raw markers data of S20 in test T5 is saved in Sub20_rawMechanics.mat under the rawMechanics.T5.Markers field, which will become available once RAW_mat_Sub20.zip is opened. Marker positions during a static calibration trial for the same subject can be found under rawMechanics.StaticCalibration field in the same MAT file (separated into Session 2 and Session 3 data). Similarly, raw EMG data of S9 in T22 is saved in Sub9_rawEnergetics.mat under the rawEnergetics.T22.EMG field, which will become available once RAW_mat_Sub9.zip is opened. In addition to static calibration and data from 30 walking tests, each MAT file also contains raw data from the two walking tests at the preferred speed, divided into two sessions.
Segmented data
CONTAINS: ground reaction force (GRF) and the feet centre of pressure (CoP) data; calculated joint and pelvic angles in all three degrees of freedom (DoFs); muscle activity data; calculated metabolic cost data (from breaths); heel-strike and toe-off events used in gait segmentation; and EMG normalisation factors including activities (e.g., walking) they were obtained from.
DESCRIPTION: Segmented data are saved in .mat format and can be accessed by opening SEGMENTED_mat_SubX.zip files. Similar to raw MAT files in RAW_mat_SubX.zip, all data is grouped per subject, resulting in 21 subject-specific groups. GRF, CoP, joint and pelvic angles, and heel-strike and toe-off events are grouped into Mechanics, while EMG data, EMG normalisation factors, and calculated metabolic cost are saved under Energetics. For example, segmented joint angles data of participant S19 in test T30 is saved in Sub19_segMechanics.mat under the segMechanics.T30.Angles field, while segmented EMG data of participant S8 in T11 is saved in Sub8_segEnergetics.mat under segEnergetics.T11.EMG field. Both .mat files will become available once relevant SEGMENTED_mat_SubX.zip files are opened. EMG normalisation factors for the same participant (i.e., S8) can be found under segEnergetics.NormFactors field in the same MAT file (separated into Session 2 and Session 3 data).
As mentioned earlier, data is segmented from the left heel-strike to the subsequent left heel-strike event, and time normalised to 101 data points. Data for each variable (e.g., hip joint angle, vertical GRF) are saved in matrices such that gait cycles always correspond to rows, and gait percentage to columns (1% of gait = 1 data point = 1 column). Except for pelvic angles and metabolic cost data, which are side-independent, all data is separated into the left and right sides. Furthermore, metabolic cost data is calculated on a breath-by-breath basis but is added to the segmented data folder as that seems appropriate.
Missing data
The PNOE device used to measure O2 consumption and CO2 production malfunctioned in several sessions, resulting in partial data loss in the case of five subjects. These include participants S5, S6, S8, S11, and S12. An overview of the metabolic cost data across all participants and conditions (5-min tests) is given in Table 6.
A wrong setting was used with the Delsys proprietary data collection software (EMGWorks) when collecting muscle activity data during stair negotiation at the beginning of Sessions 2 and 3. For this reason, and only for participants S13-S21, EMG data is missing for the right Semitendinosus muscle in stair climbing. Consequently, this muscle’s activity was set to zero when using it in an activity-based normalisation process (i.e., column 15 in a 16-column EMG matrix is zero).
Further to issues with EMG data, the sensor measuring left Tibialis Anterior malfunctioned in Session 3 for participant S15. To keep the symmetry, some sensors were reshuffled, including moving the sensor from the left Gluteus Maximus to the left Tibialis Anterior and not measuring the former, as well as removing the sensors from the right Gluteus Maximus. In raw data files, this simply means that both left and right Gluteus Maximus are zero in all tests for participant S15 in Session 3. Note, however, that data for Left Tibialis Anterior is saved in raw files in column 8 in a 16-column EMG file, corresponding to Left Gluteus Maximus.
Technical Validation
The collected data was validated to confirm consistency within and across participants, as well as in comparison to available datasets, providing confidence in its physiological accuracy and relevance. Representative trajectories are visualised by taking different participant’s data from a single session, as follows: ground reaction forces of S2 in Fig. 7; joint kinematics data of S8 in Fig. 8; metabolic activity of S17 in Fig. 9, and electrical muscle activity of S1 in Fig. 10. Further dataset validation and a demonstration of the sort of analyses enabled by our dataset is provided by comparing joint kinematics, GRF, and EMG data from S13 across the two sessions (during a 6-minute PrefStart walking trial) in Fig. 11 and by visualising temporal adaptations during a single 5-minute test from S15 in Fig. 12. All data are segmented between the subsequent heel strikes of the same leg; for visualisation purposes, GRF data of both legs are plotted between left heel strikes; on the other hand, joint angles and muscle activity are plotted between ipsilateral heel strikes (left side between left, and right side between right heel strikes). All trajectories are averaged over the last 20% of cycles (approximately the last minute of walking in a 5-minute test), and data are taken from the tests with the preferred cadence.
To assess the validity of the presented dataset, a comparative analysis is provided with two publicly available datasets that have similar walking speed conditions as our dataset. The first publicly available dataset used in the comparison is Bovi et al.10, which presents a multi-task analysis of human walking (and stair negotiation) in 20 healthy adults whose age, height, and weight distributions include the ones found in our sample (in the Bovi dataset, the participants were 43 ± 15 years of age, with average body mass 68.5 ± 15.8 kg and height 1.71 ± 0.1 m). The comparison is limited, however, due to the differences in the ways data were collected. Bovi et al. collected their data by asking participants to walk over a walkway as opposed to a treadmill, which limits their number of gait cycles and does not account for familiarisation taking place when walking over longer periods. Furthermore, the participants in Bovi et al. first walked at their preferred speed, which was then progressively increased and decreased without any precise indications of the desired gait speed. During the analysis, walking speeds were a-posteriori categorised into very slow, slow, medium, and fast walking defined by the ratio of the freely chosen speed and participant’s height. To allow comparison between the two datasets, we multiplied the average participant’s height by the average gait speed in each of the four categories and took data from two speed categories that most closely resemble gait speeds in our study. These included 1.22 m/s and 0.84 m/s, which are compared to our 1.1 m/s and 0.8 m/s trials (see Fig. 13).
The second publicly available dataset used in the comparison is van der Zee et al.72, which presents data of ten healthy adults walking at a range of speeds (0.7-2.0 m/s) in a lab. With a mean age of 24 ± 3 years, an average body mass of 73.5 ± 15 kg, and an average height of 1.76 ± 0.11 m, the participants in van der Zee et al. study are similar in size albeit a bit younger compared to participants in our study. Different from comparing our dataset to the Bovi et al. dataset, though, the comparison to van der Zee et al. dataset is more direct due to several similarities in data collection. These include subjects walking on a dual-belt instrumented treadmill at their preferred gait and 1.1 m/s. For this reason, it was possible to compare speed-matched joint kinematics and GRF, which are given in Fig. 14. A notable difference between the two datasets are shorter tests in the van der Zee et al. dataset, where participants were asked to walk only 60 seconds per condition compared to 300 seconds in our dataset.
Usage Notes
During data collection and exporting from the Vicon Nexus software, we’ve encountered several issues that are reflected in the provided datasets. To avoid these interfering with data analysis and explain occasional unexpected results, a summary of the kinematics and kinetics data features and issues is summarised in Supplementary File, Table S3 and ground reaction force issues in Table S4. Generally, the issues can be separated into test-related and export-related. The test-related issues refer to instances when a test had to be briefly stopped due to, e.g., a loose marker, which resulted in a short period of unusable data (the test recording was not stopped when such interruption happened). On the other hand, export-related issues refer to an atypical sampling frequency of the data exported from Nexus, such as ground reaction forces exported at 2 kHz instead of 1 kHz. The corrections made to the data, such as removing unusable data of a person standing on the treadmill due to marker fixture or downsampling GRF data to 1 kHz, are only done in the MAT files. The C3D files contain the raw data as it was collected/exported, with no corrections whatsoever.
Limitations
The study is designed with a focus on individual adaptations rather than trends or averages across groups. This is seen in the same group of participants being both the control and the intervention group, resulting in 30 different conditions for each participant, sufficient to investigate individual adaptations. At the same time, a small sample size (N=21) requires a cautious approach when the focus shifts away from individuals, and data are used to find trends and averages in the sample and apply the findings to the population the sample is taken from. Further to the sample characteristics, the study recruited predominantly male participants despite the efforts to make the gender distribution as equal as possible.
Studies that analyse human gait in a controlled lab environment use both overground and treadmill walking protocols, albeit more often the former13. Despite some researchers calling for a cautious translation of results between the two, no clear and uniform differences seem to exist between the two protocols40. Where our treadmill-based dataset does fall short is in addressing spontaneous changes in walking speed as documented by Ojeda et al.73. Finally, due to several issues with the PNOE metabolic cost analyser we experienced with some of the subjects, the metabolic cost measurement is missing in 36 out of 330 5-minute tests collected (about 11%). However, statistical and computational modelling tools exist in the literature that can be used to estimate the missing test values using the available MC test values. Notably, some statistical analyses can handle the amount of missing data in our dataset without the loss of statistical power.
The EMG amplitude is normalised to the peak EMG signal measured during three everyday activities – walking, sit-to-stand, and stair climbing. As highlighted by Besomi et al.70, this approach limits the normalised data analysis to the following contexts:
-
amplitude comparison within a person and muscle, within a session;
-
amplitude comparison within a person and muscle, across sessions (with caution);
-
comparison of shape/activation patterns (timing of bursts, timing of peaks, period of inactivity).
A direct amplitude comparison between muscles is not recommended with this EMG amplitude normalisation method since the comparison is done to the muscles peak activation within a given activity and not its maximum contractive capacity.
Code availability
A file containing multiple Matlab® scripts is available on figshare49 as a separate .zip file with the suffix Other. These scripts allow simple analysis and visualisation of ground reaction forces and joint angles (MAIN_KineticsKinematics.m), metabolic cost and cost of transport (MAIN_MetabolicCost.m), and muscle activation (MAIN_Emg.m). The same code can also be found on the project’s GitHub website, accompanied by the instructions on how to use the code and description of each of the three main and several auxiliary scripts/functions.
References
Molen, N. H., Rozendal, R. H. & Boon, W. Graphic representation of the relationship between oxygen-consumption and characteristics of normal gait of the human male. Proc K Ned Akad Wet C. 75, 305–314 (1972).
Ralston, H. J. Energy-speed relation and optimal speed during level walking. Int. Z. Angew. Physiol. Einschl. Arbeitsphysiol. 17, 277–283 (1958).
Selinger, J. C., O’Connor, S. M., Wong, J. D. & Donelan, J. M. Humans can continuously optimize energetic cost during walking. Curr. Biol. 25, 2452–2456 (2015).
Donelan, J. M., Kram, R. & Kuo, A. D. Mechanical work for step-to-step transitions is a major determinant of the metabolic cost of human walking. J. Exp. Biol. 205, 3717–3727 (2002).
Kuo, A. D., Donelan, J. M. & Ruina, A. Energetic consequences of walking like an inverted pendulum: step-to-step transitions. Exercise and Sport Sciences Reviews 33, 88–97 (2005).
Geyer, H., Seyfarth, A. & Blickhan, R. Compliant leg behaviour explains basic dynamics of walking and running. Proc. R. Soc. B. 273, 2861–2867 (2006).
Soo, C. H. & Donelan, J. M. Coordination of push-off and collision determine the mechanical work of step-to-step transitions when isolated from human walking. Gait Posture 35, 292–297 (2012).
Schwartz, M. H., Rozumalski, A. & Trost, J. P. The effect of walking speed on the gait of typically developing children. Journal of Biomechanics 41, 1639–1650 (2008).
Winter, D. Biomechanics and Motor Control of Human Movement. (Wiley, 2009), 4th edn.
Bovi, G., Rabuffetti, M., Mazzoleni, P. & Ferrarin, M. A multiple-task gait analysis approach: kinematic, kinetic and emg reference data for healthy young and adult subjects. Gait Posture 33, 6–13 (2011).
Stoquart, G., Detrembleur, C. & Lejeune, T. Effect of speed on kinematic, kinetic, electromyographic and energetic reference values during treadmill walking. Neurophysiol Clin 38, 105–116 (2008).
Murley, G. S., Menz, H. B. & Landorf, K. B. Electromyographic patterns of tibialis posterior and related muscles when walking at different speeds. Gait Posture 39, 1080–1085 (2014).
Fukuchi, C. A., Fukuchi, R. K. & Duarte, M. Effects of walking speed on gait biomechanics in healthy participants: a systematic review and meta-analysis. Systematic reviews 8, 153 (2019).
Ferber, R., Osternig, L. R., Woollacott, M. H., Wasielewski, N. J. & Lee, J. H. Reactive balance adjustments to unexpected perturbations during human walking. Gait Posture 16, 238–248 (2002).
Cajigas, I., Koenig, A., Severini, G., Smith, M. & Bonato, P. Robot-induced perturbations of human walking reveal a selective generation of motor adaptation. Science Robotics 2, eaam7749 (2017).
Vlutters, M., van Asseldonk, E. H. F. & van der Kooij, H. Lower extremity joint-level responses to pelvis perturbation during human walking. Scientific Reports 8, 14621 (2018).
Gerards, M. H. G. et al. Adaptability to balance perturbations during walking as a potential marker of falls history in older adults.Front Sports Act Living 3 (2021).
Kerrigan, D., Todd, M. K., Croce, U. D., Lipsitz, L. A. & Collins, J. J. Biomechanical gait alterations independent of speed in the healthy elderly: evidence for specific limiting impairments. Archives of Physical Medicine and Rehabilitation 79, 317–322 (1998).
Silder, A., Heiderscheit, B. & Thelen, D. G. Active and passive contributions to joint kinetics during walking in older adults. Journal of Biomechanics 41, 1520–1527 (2008).
Monaco, V., Rinaldi, L. A., Macrì, G. & Micera, S. During walking elders increase efforts at proximal joints and keep low kinetics at the ankle. Clinical Biomechanics 24, 493–498 (2009).
Lee, H.-J., Chang, W. H., Choi, B.-O., Ryu, G.-H. & Kim, Y.-H. Age-related differences in muscle co-activation during locomotion and their relationship with gait speed: a pilot study. BMC Geriatrics 17, 44 (2017).
Sloot, L. et al. Walk this way: elderly walk like the young, just more slowly. Gait Posture 81, 348–349 (2020).
Sloot, L. et al. Decline in gait propulsion in older adults over age decades. Gait Posture 90, 475–482 (2021).
Hsu, A.-L., Tang, P.-F. & Jan, M.-H. Analysis of impairments influencing gait velocity and asymmetry of hemiplegic patients after mild to moderate stroke. Arch Phys Med Rehabil. 84, 1185–1193 (2003).
Jonkers, I., Delp, S. & Patten, C. Capacity to increase walking speed is limited by impaired hip and ankle power generation in lower functioning persons post-stroke. Gait Posture 29, 129–137 (2009).
Hsiao, H., Knarr, B. A., Higginson, J. S. & Binder-Macleod, S. A. The relative contribution of ankle moment and trailing limb angle to propulsive force during gait. Hum Mov Sci. 39, 212–221 (2015).
Mahon, C. E., Farris, D. J., Sawicki, G. S. & Lewek, M. D. Individual limb mechanical analysis of gait following stroke. Journal of Biomechanics 48, 984–989 (2015).
Farris, D. J., Hampton, A., Lewek, M. D. & Sawicki, G. S. Revisiting the mechanics and energetics of walking in individuals with chronic hemiparesis following stroke: from individual limbs to lower limb joints. J. Neuroeng. Rehabil. 12 (2015).
Lewek, M. D., Raiti, C. & Doty, A. The presence of a paretic propulsion reserve during gait in individuals following stroke. Neurorehabil Neural Repair. 32, 1011–1019 (2018).
Reisman, D. S., Rudolph, K. S. & Farquhar, W. B. Influence of speed on walking economy poststroke. Neurorehabil Neural Repair 23, 529–534 (2009).
Stoquart, G., Detrembleur, C. & Lejeune, T. M. The reasons why stroke patients expend so much energy to walk slowly. Gait Posture 36, 409–413 (2012).
Finley, J. M. & Bastian, A. J. Associations between foot placement asymmetries and metabolic cost of transport in hemiparetic gait. Neurorehabil Neural Repair 31, 168–177, https://doi.org/10.1177/1545968316675428 (2016).
Sanchez, N. & Finley, J. Individual differences in locomotor function predict the capacity to reduce asymmetry and modify the energetic cost of walking poststroke. Neurorehabil Neural Repair 32, 701–713 (2018).
Roemmich, R. T., Leech, K. A., Gonzalez, A. J. & Bastian, A. J. Trading symmetry for energy cost during walking in healthy adults and persons poststroke. Neurorehabil Neural Repair 33, 602–613 (2019).
McCain, E. M. et al. Reduced joint motion supersedes asymmetry in explaining increased metabolic demand during walking with mechanical restriction. Journal of Biomechanics 126, 110621 (2021).
Mentiplay, B. F., Banky, M., Clark, R. A., Kahn, M. B. & Williams, G. Lower limb angular velocity during walking at various speeds. Gait Posture 65, 190–196 (2018).
Lim, Y. P., Lin, Y.-C. & Pandy, M. G. Lower-limb muscle function in healthy young and older adults across a range of walking speeds. Gait Posture 94, 124–130 (2022).
Lim, Y. P., Lin, Y.-C. & Pandy, M. G. Effects of step length and step frequency on lower-limb muscle function in human gait. Journal of Biomechanics 57, 1–7 (2017).
Moore, J. K., Hnat, S. K. & van den Bogert, A. J. An elaborate data set on human gait and the effect of mechanical perturbations. PeerJ 3, e918, https://doi.org/10.7717/peerj.918 (2015).
Fukuchi, C. A., Fukuchi, R. K. & Duarte, M. A public dataset of overground and treadmill walking kinematics and kinetics in healthy individuals. PeerJ 6, e4640, https://doi.org/10.7717/peerj.4640 (2018).
Lencioni, T., Carpinella, I., Rabuffetti, M., Marzegan, A. & Ferrarin, M. Human kinematic, kinetic and emg data during different walking and stair ascending and descending tasks. Scientific Data 6, 309 (2019).
Horst, F., Lapuschkin, S., Samek, W., Müller, K.-R. & Schöllhorn, W. I. A public dataset of overground walking kinetics and full-body kinematics in healthy adult individuals https://doi.org/10.17632/svx74xcrjr.3 (2019).
Moreira, L., Figueiredo, J., Fonseca, P., Vilas-Boas, J. P. & Santos, C. P. Lower limb kinematic, kinetic, and emg data from young healthy humans during walking at controlled speeds. Scientific Data 8, 103 (2021).
van der Zee, T. J., Mundinger, E. M. & Kuo, A. D. A biomechanics dataset of healthy human walking at various speeds, step lengths and step widths. Scientific Data 9, 704 (2022).
Booij, M. J. et al. Matching walking speed of controls affects identification of gait deviations in patients with a total knee replacement. Clinical Biomechanics 82 (2021).
Kerrigan, D. C., Frates, E. P., Rogan, S. & Riley, P. O. Hip hiking and circumduction: Quantitative definitions. American Journal of Physical Medicine & Rehabilitation 79 (2000).
Inoue, S. et al. Determinants of step-through gait pattern acquisition in subacute stroke patients. Prog Rehabil Med 7, – (2022).
Baček, T. et al. Varying joint patterns and compensatory strategies can lead to the same functional gait outcomes: A case study. 1–6 (2022).
Baček, T. et al. A biomechanics and energetics dataset of neurotypical adults walking with and without kinematic constraints. figshare https://doi.org/10.26188/c.6887854.v1 (2023).
Meyer, C. et al. Familiarization with treadmill walking: How much is enough? Sci. Rep. 9, 5232 (2019).
Holt, K. G., Hamill, J. & Andres, R. O. Predicting the minimal energy costs of human walking. Med Sci Sports Exerc 23, 491–498 (1991).
Dingwell, J. B. & Marin, L. C. Kinematic variability and local dynamic stability of upper body motions when walking at different speeds. Journal of biomechanics 39, 444–452 (2006).
Chung, M.-J. & Wang, M.-J. J. The change of gait parameters during walking at different percentage of preferred walking speed for healthy adults aged 20-60 years. Gait Posture 31, 131–135 (2010).
Cifrek, M., Medved, V., Tonković, S. & Ostojić, S. Surface emg based muscle fatigue evaluation in biomechanics. Clinical Biomechanics 24, 327–340 (2009).
Ghazwan, A., Forrest, S. M., Holt, C. A. & Whatling, G. M. Can activities of daily living contribute to emg normalization for gait analysis? PLOS ONE 12, e0174670 (2017).
Selinger, J. C. & Donelan, J. M. Estimating instantaneous energetic cost during non-steady-state gait. Journal of Applied Physiology 117, 1406–1415 (2014).
Collins, S. H., Wiggin, M. B. & Sawicki, G. S. Reducing the energy cost of human walking using an unpowered exoskeleton. Nature 522 (2015).
Galle, S., Malcolm, P., Collins, S. H. & Clercq, D. D. Reducing the metabolic cost of walking with an ankle exoskeleton: interaction between actuation timing and power. J NeuroEngineering Rehabil 14, 35 (2017).
Zhang, J. et al. Human-in-the-loop optimization of exoskeleton assistance during walking. Science 356, 1280–1284 (2017).
Malcolm, P., Galle, S., Derave, W. & Clercq, D. D. Bi-articular knee-ankle-foot exoskeleton produces higher metabolic cost reduction than weight-matched mono-articular exoskeleton. Frontiers in Neuroscience 12, https://www.frontiersin.org/articles/10.3389/fnins.2018.00069 (2018).
Perry, J., Garrett, M., Gronley, J. & Mulroy, S. J. Classification of walking handicap in the stroke population. Stroke 26, 982–989 (1995).
Awad, L. N., Palmer, J. A., Pohlig, R. T., Binder-Macleod, S. A. & Reisman, D. S. Walking speed and step length asymmetry modify the energy cost of walking after stroke. Neurorehabil Neural Repair 29, 416–423 (2015).
Hornby, T. G. et al. Variable intensive early walking poststroke (views): a randomized controlled trial. Neurorehabil Neural Repair 30, 440–450 (2016).
Mahtani, G. B. et al. Altered sagittal- and frontal-plane kinematics following high-intensity stepping training versus conventional interventions in subacute stroke. Physical therapy 97, 320–329 (2017).
Hamill, J., Selbie, W. & Kepple, T. Three-diomensional kinematics (Human Kinetics, 2014).
Robertson, D., Caldwell, G. E., Hamill, J., Kamen, G. & Whittlesey, S. N. Research Methods in Biomechanics (2013), 2nd edn.
Wu, G. et al. Isb recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion—part i: ankle, hip, and spine. Journal of Biomechanics 35, 543–548 (2002).
Raffalt, P. C., Kent, J. A., Wurdeman, S. R. & Stergiou, N. Selection procedures for the largest lyapunov exponent in gait biomechanics. Annals of Biomedical Engineering 47, 913–923 (2019).
Konrad, P. The ABC of EMG: a practical introduction to kinesiological electromyography (Noraxon USA, Inc, 2006).
Besomi, M. et al. Consensus for experimental design in electromyography (cede) project: Amplitude normalization matrix. J Electromyogr Kinesiol. 53 (2020).
Brockway, J. Derivation of formulae used to calculate energy expenditure in man. Hum Nutr Clin Nutr 41, 463–471 (1987).
van der Zee, T. J., Mundinger, E. M. & Kuo, A. D. Biomechanics dataset of healthy human walking at various conditions. figshare https://doi.org/10.6084/m9.figshare.16530939.v4 (2022).
Ojeda, L. V., Rebula, J. R., Kuo, A. D. & Adamczyk, P. G. Influence of contextual task constraints on preferred stride parameters and their variabilities during human walking. Medical Engineering & Physics 37, 929–936 (2015).
Acknowledgements
The authors would like to thank Prof. Gavin Williams of the Epworth Hospital and the University of Melbourne, Prof. Jennifer McGinley of the Physiotherapy Department at the University of Melbourne, and Dr. Liuhua Peng, lecturer of the School of Mathematics and Statistics with the University of Melbourne for their expertise in designing the study. The authors would also like to express sincere gratitude to the 21 participants who volunteered their time and effort to participate in our study. Their contributions were invaluable and will be crucial in bettering our understanding of the underlying walking mechanisms. The authors thank them for their patience and cooperation throughout the study. Without their participation, this research would not have been possible.
Author information
Authors and Affiliations
Contributions
T.B. initiated, ideated, prepared, and led the experimental study and data collection, wrote data analysis code, exported and analysed data, drafted all manuscript versions, and prepared figures, tables, and data visualisation. M.S., H.L., and Z.C. participated in designing and carrying out the study protocol and provided feedback on the manuscript. C.M. and E.B. contributed to the design of the project concept, project supervision, and provided feedback on the manuscript. D.K., D.O., and Y.T. provided feedback on the manuscript and contributed to developing methodology, data analysis and interpretation, project administration and supervision, and secured funding for the project.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Baček, T., Sun, M., Liu, H. et al. A biomechanics and energetics dataset of neurotypical adults walking with and without kinematic constraints. Sci Data 11, 646 (2024). https://doi.org/10.1038/s41597-024-03444-4
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41597-024-03444-4
- Springer Nature Limited