Abstract
The noise characteristics of the optoelectronic channel in an atomic-absorption spectrometer were studied. The spectrometer may be used with spiral and graphite electrothermal atomizers. The noise was measured during the development of a glow discharge in a hollow-cathode tube (HCT) at current-pulse lengths of 50 and 500 μs and a filling factor of 2–20. It was found that the rms noise level in the optoelectronic channel decreased with increasing duration of the current pulses in the HCT. The results are compared to the rms noise level in the optoelectronic channel under conditions of continuous HCT feeding. The noise component of the relative measurement error is shown to be 5–10%, depending on the material of the HCT cathode and the measurement time (with reference to the beginning of the current pulse). It is demonstrated that the HCT is suitable for atomic-absorption spectrometers with the pulsed and continuous excitation.
Similar content being viewed by others
REFERENCES
Kureichik, K.P., Impul'snaya atomnaya spektrometriya.Metody izmerenii.Apparatura (Pulse Atomic Spectroscopy. Measurement Methods. Equipment), Minsk: Universitetskoe, 1989.
Kureichik, K.P., Bezlepkin, A.I., Khomyak, A.S., and Aleksandrov, V.V., Gazorazryadnye istochniki sveta dlya spektral'nykh izmerenii (Gas-Discharge Light Sources for Spectral Measurements), Minsk: Universitetskoe, 1987.
Kureichik, K.P., Gelios Small-Size Atomic-Absorption Spectrometer with Helical Atomizer, Materialy 1-oi Mezhdun.konf.po metrologii (Proc. of the 1st Int. Conf. on Metrology), Minsk: BelGIM, 1997.
Max, J., Methodes et Techniques de Traitement du Signal et Applications aux Mesures Physigues, New York: Masson, 1981. Translated under the title Metody i tekhnika obrabotki signalov pri fizicheskikh izmereniyakh, Moscow: Mir, 1983.
Kureichik, K.P., Pupkevich, S.N., Granos, V.G., and Khramchenkov, I.S., Programmno-apparatnyi kompleks Gelios-M – sredstvo povysheniya metrologicheskikh i servisnykh kharakteristik spektrometrov tipov AAS, S-115, Saturn (Gelios-M Soft–Hardware Complex as a facility for Improving the Metrological and Service Functions of the AAS, C-115, and Saturn type Spectrom-eters), Minsk: Metrologiya i Priborostroenie, 1998.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Kureichik, K.P., Mavlyutov, M.M., Kharitonchik, V.I. et al. A Noisy Hollow-Cathode Tube in Pulsed and Continuous Excitation Regimes. Instruments and Experimental Techniques 47, 408–412 (2004). https://doi.org/10.1023/B:INET.0000032912.53161.f9
Issue Date:
DOI: https://doi.org/10.1023/B:INET.0000032912.53161.f9