Characteristics of a Sector of the Endcap Hadron Calorimeter for the CMS Facility

  • Published:
Instruments and Experimental Techniques Aims and scope Submit manuscript

Abstract

The characteristics of the prototype of the endcap hadron calorimeter for the CMS facility have been measured. Using the relations between the measured calorimeter response to a radiation source, muons, and pions, it is possible to determine the energy scale of the data-acquisition electronics, which will be used in future experiments along with the calorimeter. The light yield in the calorimeter due to a minimum-ionizing particle was measured. The effect of various factors on the duration of the calorimeter signal is analyzed. The joint operation of the hadron and electromagnetic calorimeters was investigated. The possibility of adjusting the uncompensated system using the data from a scintillation counter inserted between the calorimeters is analyzed. It is shown that the presence of a structural material between the calorimeters will not lead to a noticeable degradation in the energy resolution of the hadron calorimeter.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

REFERENCES

  1. Bayatian, G.L., Grigorian, N.K., Kachatrian, V.G., et al., CERN/LHCC 97-31. Geneve, June 20, 1997.

  2. Bellamy, E.H., Bellettini, G., Gervelli, F., et al.,Nucl. Instrum. Methods Phys. Res., Sect. A, 1994, vol. 339, p. 468.

    Google Scholar 

  3. Brun, R. and Rademakers, F., Nucl. Instrum. Methods Phys. Res., Sect. A, 1997, vol. 389, p. 81.

    Google Scholar 

  4. Malyukov, S.N., Minashvili, I.A., Romanovskii, V.I., et al., Preprint of Joint Inst. Nucl. Res., Dubna, 1995, no. P1-95-283.

  5. Alde, D., Binon, F.G., Bricman, C., et al., Nucl. Instrum. Methods Phys. Res., Sect. A, 1988, vol. 268, p. 112; Binon, F.G., Bricman, C., Duteil, P., et al., Nucl. Instrum. Methods Phys. Res., Sect. A, 1988, vol. 268, p. 101.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Goncharov, P.I., Abramov, V.V., Bencze, G. et al. Characteristics of a Sector of the Endcap Hadron Calorimeter for the CMS Facility. Instruments and Experimental Techniques 47, 47–52 (2004). https://doi.org/10.1023/B:INET.0000017249.54819.0c

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/B:INET.0000017249.54819.0c

Keywords

Navigation