Abstract
We describe an algorithm for radionuclide detection and identification by the γ-ray spectra recorded with a high-pressure xenon γ-ray spectrometer. The algorithm is based on the comparison of the measured spectra with the tabulated radionuclide data. The fitting criteria were formulated. The software package, implementing the algorithm and providing the execution of a complete cycle of γ-ray spectrum processing, was developed. The algorithm usability and efficiency were demonstrated by testing it with actual spectra.
Similar content being viewed by others
REFERENCES
Gratchev, V.M., Dmitrenko, V.V., Ulin, S.E., et al., Abstracts of Papers, SPIE Hard X-ray, Gamma-Ray, and Neutron Detectors Physics Conf., Denver, 1999, vols. 37-68, p. 271.
Bolotnikov, A.E., Grachev, V.M., Chernysheva, I.V., et al., Abstracts of Papers, Int. Conf. on Liquid Radiation Detectors: Their Fundamental Properties and Applications, Japan (ICLRD), Tokyo: Waseda University, 1992, p. 462.
Dmitrenko, V.V., Dvornyak, A.G., Grachev, V.M., et al., Nucl. Instrum. Methods Phys. Res., Sect. A, 1999, vol. 422, p. 326.
Dmitrenko, V.V., Samosadnyi, V.T., Kadilin, V.V., et al., Prib. Sist. Upr., 1998, no. 9, p. 60.
Grachev, V.M., Dmitrenko, V.V., Kondakova, O.N., et al., Abstracts of Papers, γ-Spectrometers with High Energy Resolution, Nuclear Science Symp., Anaheim, California, 1996; Conference Record, 1996, vol. 2, p. 938.
Tsoulfanidis, N., Measurement and Detection of Radiation, Washington: Taylor & Francis, 1995.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Vlasik, K.F., Grachev, V.M., Dmitrenko, V.V. et al. An Automatic Data-Processing Technique for the High-Pressure Xenon γ-Ray Spectrometer. Instruments and Experimental Techniques 43, 729–734 (2000). https://doi.org/10.1023/A:1026699229568
Issue Date:
DOI: https://doi.org/10.1023/A:1026699229568