Skip to main content
Log in

k0-Instrumental Neutron Activation Analysis Establishment at CDTN, Brazil: A successful story

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

Since 1995 the k 0 instrumental neutron activation analysis has been applied at Radiochemical Laboratory, CDTN/CNEN, Brazil, by means of TRIGA MARK I IPR-R1 research reactor. At that time α, f, and T n were determined and the most recent determination of these parameters confirmed the great stability of the reactor along these years. In order to verify the efficiency and accuracy of the method, several certified reference materials have been systematically analyzed. Participating in Intercomparison Exercises organized by IAEA has been an important, essential and useful procedure to quality control. CDTN is the only Brazilian Institute to apply the k 0-INAA to determine elements by means of their isotopes through short, medium and long half life using its own nuclear reactor.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. P. C. TÓfani, M. Paiano, Uses of a Small Research Reactor in Brazil, NUCLEBRÁS, CDTN, CNEN/CDTN-611, Belo Horizonte, 1989.

  2. C. V. S. Sabino, H. M. Rossi, G. F. Kastner, M. B. Franco, Testes relativos a implantação do método k0 no reator IPR R1, CDTN/CNEN, CDTN-805/95, Belo Horizonte, 1995 (in Portuguese).

  3. F. De Corte, The k0-standardisation method; a move to the optimisation of neutron activation analysis, Ryksuniversiteit Gent, Faculteit Van de Wetenschappen, 1986, p. 464.

    Google Scholar 

  4. K. Heydorn, E. Damsgaard, J. Radioanal. Nucl. Chem., 179 (1994) 87.

    Google Scholar 

  5. E. H. Montoya, Evalucion y estandarizacion del analisis por activacion neutronica segun el metodo del ksub cero en el reactor nuclear PR-10; Estudio preliminar empleando irradiaciones cortas. Lima: Universidad Peruana Cayetano Heredia, Escuela Peruana de post grado Victor Aezamona Castro, 1995, p. 92.

  6. E. M. Hryntakis, J. I. Kim, Radiochim. Acta, 22 (1995) 128.

    Google Scholar 

  7. M. Â. B. C. Menezes, C. V. S. Sabino, A. M. Amaral, E. C. P. Maia, J. Radioanal. Nucl. Chem., 245 (2000) 173.

    Google Scholar 

  8. M. A. R. V. Veado, J. C. C. Veado, A. H. Oliveira, M. Â. B. C. Menezes, M. M. Melo, Estudo de Metais Pesados em Amostras de Sangue, Urina e Leite Bovino e Pastagem, na Região de Curvelo-Minas Gerais. (A study of heavy metals in bovine blood, urine and milk and pasture in Curvelo Region — Minas Gerais), in: Encontro de Aplicações Nucleares (Meeting on Nuclear Applications), V, 15-20 Oct 2000, Rio de Janeiro, Proceedings, ABEN, Rio de Janeiro, 2000, CD-ROM (in Portuguese).

  9. M. Â. B. C. Menezes, C. V. S. Sabino, A. M. Amaral, W. Souza, G. F. Kastner, D. Francisco, Constituintes em alimentos: determinação por método paramétrico (Food constituents: determination by means of parametric method), in: Encontro de Aplicações Nucleares (Meeting on Nuclear Applications), 4. Poços de Caldas, 18.22 Aug 1997 (in Portuguese).

  10. J. V. Bandeira, G. G. Pinto, C. V. S. Sabino, E. G. Agudo, The use of 99mTc as an adsorbable tracer for studying the dynamics of fine sediments in suspension, IAEA-SM-361/13, Intern. Symp. on Isotope Techniques in Water Resources Development and Management, Vienna, Austria, 10-14 May, 1999.

  11. P. E. Aun, J. V. Bandeira, The role of nuclear techniques in sedimentological studies and some applications in Latin America, in: IAEA-TECDOC-818: Use of Nuclear Techniques in Studying Soil Erosion and Siltation, Vienna, Austria, 1995.

  12. C. V. S. Sabino, A. P. Prous, I. Wust, F. N. O. Neves, M. B. Franco, Study archaeological and chemiometric of ceramics from Guará site, Goiás, Brazil, Química Nova, in press (in Portuguese).

  13. M. Â. B. C. Menezes, E. C. P. Maia, O. F. Neves, J. R. Batista, K0-Ativação Neutrônica Paramétrica: Avaliação da Contaminação em Trabalhadores Utilizando o Biomonitor Cabelo. (Parametric neutron activation: evaluation of workers.contamination using hair biomonitor) In: Encontro de Aplicações Nucleares (Meeting on Nuclear Applications), V, 15.20 Oct 2000, Rio de Janeiro. Proceedings, ABEN, Rio de Janeiro, 2000, CD-ROM (in Portuguese).

  14. A. Bleise, B. Smodis (Eds), Report on the Intercomparison Run NAT-3 for the Determination of Trace and Minor Elements in Urban Dust Artificially Loaded on Air Filters, International Atomic Energy Agency, Vienna, 1999, p. 119 (NAHRES-43).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Menezes, M.Â.d.B., Sabino, C.d.V.S., Franco, M.B. et al. k0-Instrumental Neutron Activation Analysis Establishment at CDTN, Brazil: A successful story. Journal of Radioanalytical and Nuclear Chemistry 257, 627–632 (2003). https://doi.org/10.1023/A:1026104613854

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1026104613854

Keywords

Navigation