Skip to main content
Log in

Gadolinium susceptibility artifact causing false positive stenosis isolated to the proximal common carotid artery in 3D dynamic contrast medium enhanced MR angiography of the thorax – a brief review of causes and prevention

  • Published:
The International Journal of Cardiovascular Imaging Aims and scope Submit manuscript

Abstract

Due to the close proximity of arteries and veins in the superior mediastinum and upper extremities, T2* shortening effects of the gadolinium within the central veins may cause artifactual vascular stenosis (susceptibility artifact) on arterial-phase MR angiographic images of the major branches of the aortic arch. We report a case of artifactual stenosis isolated to the origin of the left common carotid artery on arterial-phase MR angiography, secondary to susceptibility artifact from non-diluted gadolinium in the adjacent brachiocephalic vein. The cause of the artifact, its identification and prevention is reviewed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Prince MR. Gadolinium-enhanced MR aortography. Radiology 1994; 191: 155–164.

    Google Scholar 

  2. Siegelman ES, Charafeddine R, Stolpen AH, Axel L. Suppression of intravascular signal on fat-saturated contrast enhanced thoracic MR arteriograms. Radiology 2000 Oct; 217(1): 115–118.

    Google Scholar 

  3. Lee YJ, Chung TS, Joo JY, Chien D, Laub G. Suboptimal contrast-enhanced carotid MR angiography from the left brachiocephalic venous stasis. J Magn Reson Imaging 1999 Oct; 10(4): 503–509.

    Google Scholar 

  4. Neimatallah MA, Chenevert TL, Carlos RC, et al. Subclavian MR arteriography: reduction of susceptibility artifact with short echo time and dilute Gadolinium. Radiology 2000 Nov; 217(2): 581–586.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Tirkes, A.T., Rosen, M.A. & Siegelman, E.S. Gadolinium susceptibility artifact causing false positive stenosis isolated to the proximal common carotid artery in 3D dynamic contrast medium enhanced MR angiography of the thorax – a brief review of causes and prevention. Int J Cardiovasc Imaging 19, 151–155 (2003). https://doi.org/10.1023/A:1022836930797

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1022836930797

Navigation