Abstract
Objectives
To compare a novel, non-contrast, flow-independent, 3D isotropic magnetic resonance angiography (MRA) sequence that combines respiration compensation, electrocardiogram (ECG)-triggering, undersampling, and Dixon water-fat separation with an ECG-triggered aortic high-pitch computed tomography angiography (CTA) of the aorta.
Materials and methods
Twenty-five patients with recent CTA were scheduled for non-contrast MRA on a 3 T MRI. Aortic diameters and cross-sectional areas were measured on MRA and CTA using semiautomatic measurement tools at 11 aortic levels. Image quality was assessed independently by two radiologists on predefined aortic levels, including myocardium, proximal aortic branches, pulmonary veins and arteries, and the inferior (IVC) and superior vena cava (SVC). Image quality was assessed on a 5-point Likert scale.
Results
All datasets showed diagnostic image quality. Visual grading was similar for MRA and CTA regarding overall image quality (0.71), systemic arterial image quality (p = 0.07–0.91) and pulmonary artery image quality (p = 0.05). Both readers favored MRA for SVC and IVC, while CTA was preferred for pulmonary veins (all p < 0.05). No significant difference was observed in aortic diameters or cross-sectional areas between native MRA and contrast-enhanced CTA (p = 0.08–0.94).
Conclusion
The proposed non-contrast MRA enables robust imaging of the aorta, its proximal branches and the pulmonary arteries and great veins with image quality and aortic diameters and cross-sectional areas comparable to that of CTA. Moreover, this technique represents a suitable free-breathing alternative, without the use of contrast agents or ionizing radiation. Therefore, it is especially suitable for patients requiring repetitive imaging.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Diseases of the aorta are among the leading causes of morbidity and mortality in Western countries [1]. They include aortic aneurysms, acute aortic syndromes such as aortic dissection, atherosclerotic lesions, inflammatory diseases, and genetic and congenital abnormalities, such as Marfan or Loeys-Dietz syndrome and malformations of the aortic arch [2]. While some of these conditions require immediate surgical or interventional therapy, many cases also require repeated follow-up imaging [2]. Early detection of vascular changes is essential for timely interventions, including increased aortic aneurysm diameter, dissection, penetrating aortic ulcers prone to rupture, or aortic coarctation grading [3, 4].
Repetitive imaging is mandatory during follow-up and after endovascular aortic repair or open surgery, and several imaging methods are available. Ultrasound offers excellent temporal and spatial resolution and the possibility to quantify flow. However, parts of the great vessels often remain hidden due to the lack of acoustic windows. Computed tomography (CT) is considered the gold standard in aortic assessment but increases the radiation-induced lifetime risk of cancer mortality [5]. High rates of repeated imaging are considered problematic, particularly in younger patients [6], given the potential cumulative side effects of CT scanning. Moreover, CT relies on iodine-based contrast agents, increasing risks in patients with impaired renal function [7].
Magnetic resonance imaging (MRI) may be the preferred approach for avoiding radiation exposure. MRI enables flow quantification but is not constrained by the lack of acoustic windows that limits ultrasound. Classic gadolinium-based contrast-enhanced magnetic resonance angiography (CE-MRA) delivers excellent spatial and contrast resolution with short scan times. The quality of this technique strongly depends on the proper timing of contrast injection and data acquisition and the patient’s breath-hold capabilities, limiting its use to compliant patients [8].
In addition, the repetitive use of contrast agents may lead to allergic reactions, brain retention, or nephrogenic systemic sclerosis in end-stage renal disease [9,10,11,12,13]. Finally, the achievable spatial resolution in CE-MRA is limited by bolus timing and breath-hold duration. In addition, several non-contrast magnetic resonance angiography (MRA) sequences have been developed, such as electrocardiogram (ECG)-gated fast spin-echo, balanced steady-state free precession (bSSFP), spoiled gradient echo, and black blood MRI [14, 15].
Fat suppression can further improve MRA readability and presentation. In bright blood imaging, missing or insufficient fat suppression may lead to inadequate discrimination between the vessel lumen and surrounding fat. While spectral fat saturation can be limited by its high sensitivity to magnetic field inhomogeneities, robust Dixon water-fat separation has been proven effective in cardiovascular imaging [16,17,18,19]. In addition, compressed sensing reduces image noise and enables reduced acquisition times due to a sparse representation of the acquired object, a pseudo-random sub-sampling of k-space, and a nonlinear iterative image reconstruction [20, 21]. Both techniques may aid in overcoming the known drawbacks of the widely used bSSFP sequences: sensitivity to off-resonance effects and steady-state disruptions [22].
This study’s primary objective was to assess a newly developed non-contrast, flow-independent, 3D isotropic MRA sequence that combines respiratory compensation, ECG-triggering, compressed sensing, and Dixon water-fat separation at 3 T for the chest and abdomen. This MRA sequence was compared to ECG-gated high-pitch CT angiography (CTA), which is currently considered the clinical gold standard for aortic imaging. This study focused on achieving consistent aortic diameter measurements as its primary endpoint, while its secondary endpoint involved assessing subjective image quality.
Materials and methods
Patients
The local Institutional Review Board approved the study protocol (approval number: 59_21B), which complies with the Health Insurance Portability and Accountability Act criteria and the Declaration of Helsinki. All patients signed an informed consent form before study enrolment.
We retrospectively screened patients who underwent aortic CT examinations with third-generation dual-source CT (Somatom Force; Siemens Healthcare GmbH, Forchheim, Germany) over 15 months (January 2020 to May 2021) for participation in this study, identifying 168 patients. The exclusion criteria were death (n = 3) or debilitating illness (n = 21), age < 18 years (n = 3), colonization with multi-drug resistant microbes (n = 4), residential distance > 100 km from the hospital (n = 6), metallic aortic foreign materials (n = 34), or contraindications for MRI (i.e., claustrophobia or unsafe implants; n = 12). We contacted the remaining 85 patients by telephone and letter, of which 25 agreed to participate in this study. We did not ask for the reasons for non-participation to respect the patient’s privacy.
The study population comprised eight women and 17 men (mean age: 62 ± 13 years). Initial indications for CT were suspected aortic dissection (n = 14), aortic aneurysm (n = 5), and workup before planned interventions, such as transcatheter aortic valve implantation or percutaneous coronary intervention (n = 3), unknown structure at the aortic root (n = 1), known aortic dissection (n = 1), and aortic coarctation (n = 1).
At study entry, the participants’ mean weight was 90 ± 22 kg, mean height was 174 ± 11 cm, and mean body mass index was 30 ± 6 kg/m2. Their mean heart rate during the MRI exam was 68 ± 8 beats/min.
MRI protocol
Cardiovascular MRI was performed on a 3-T MRI system (MAGNETOM Vida; Siemens Healthcare, Erlangen, Germany) with dedicated phased-array receiver coils (an 18-channel body coil array and 32-channel spine coil array). A single coil array was used for the thoracic aorta, and when clinically indicated, a second coil array was added to assess the abdominal aorta.
The prototypical native MRA acquisition was planned as a coronal slab. The number of slices was adapted individually to include the entire aorta and heart. Geometrical parameters included a field of view of 450 × 450 × 156 ± 24 mm3 and an acquired and reconstructed resolution of 1.2 × 1.2 × 1.2 mm3. A two-point Dixon with echo times of 1.3 or 2.9 ms was used. An undersampling factor of R = 11 was achieved using a Poisson-disc-like incoherent sampling pattern combined with an iterative compressed sensing reconstruction approach. An adiabatic T2-preparation pulse was used for optimal vessel contrast. Prospective ECG-gating in an end-diastolic phase was used to avoid heart motion. A cross-beam navigator was placed onto the liver dome, and the position of the liver-diaphragm interface was tracked before every acquisition window to mitigate artifacts from respiratory motion. An accept-reject algorithm was applied with an acceptance window of ± 4 mm at end-expiration. All images were reconstructed inline in the MRI system.
CTA protocol
CTA imaging was performed on a third-generation dual-source scanner (SOMATOM Force; Siemens Healthcare, Erlangen, Germany) covering the entire thorax and abdomen. The scans were prospectively ECG triggered in the high-pitch mode (collimation = 2 × 192 × 0.6 mm, pitch = 3.2), and data were only acquired during end-diastole to avoid heart motion. For each patient, an arterial phase acquisition with bolus triggering in the ascending aorta was performed in the head-feet direction. When clinically indicated, an additional venous phase acquisition in the head-feet direction was performed 20 s after the first pass. Automatic tube current modulation (Care Dose 4D; reference = 180–204 mAs, depending on patient girth) and automatic tube voltage selection (Care kV; reference = 120 kV) were used for all patients. A total of 50–80 mL (mean = 64.7 mL ± 11 mL) of iodinated contrast agent (Imeron 350, Bracco, Milan, Italy), followed by 50 mL of 0.9% NaCl, were administered through a peripheral indwelling cannula at the right or left upper extremity at a 4 mL/s flow rate. Images were reconstructed in 0.6 mm slices in the transversal plane using smooth (Bv40) kernels using iterative reconstructions.
Measurements
A dedicated vascular image interpretation workflow supported the evaluation of the aortic diameters (CT Vascular; Syngo.via VB50; Siemens Healthcare GmbH, Erlangen, Germany) with automated centerline definitions. Manual corrections of the centerlines were added by the readers when necessary. The effective inner diameter and cross-sectional area were documented at predefined aortic levels (i.e., aortic annulus, sinus of Valsalva, sinotubular junction, mid ascending aorta, proximal aortic arch, mid aortic arch, proximal descending aorta, mid descending aorta, diaphragm level, celiac trunk level, and above the bifurcation) [2].
Image quality analysis
Two board-certified reviewers ([blinded for review], with 10 and 7 years of experience in cardiovascular imaging, respectively), who were blinded to all clinical and imaging data, evaluated the datasets. The presentation started in the original orientation, and images were reviewed in free multiplanar reformation angulations at the discretion of the raters using a dedicated three-dimensional (3D) viewer (Horos v. 3.3.6; distributed under the LGPL license by Horosproject.org).
Overall image quality and water-fat separation were rated on a five-point scale [23]: 5 = excellent image quality, interpretable with no artifacts; 4 = good image quality, interpretable with minimal artifacts; 3 = average image quality, interpretation mildly degraded by image artifacts; 2 = below average image quality, interpretable but moderately degraded; 1 = poor image quality, uninterpretable images. The image quality of the myocardium, the aorta at the 11 abovementioned predefined levels, the thoracic and abdominal side branches, the pulmonary arteries, and the vena cavae were evaluated on a similar scale (Table 1). In cases of impaired image quality, the reason was documented in each case.
Statistical analysis
Interval-level data were evaluated for normality using the Shapiro–Wilk test. Data are presented as mean ± standard deviation (SD) or median (range). Data were compared using a paired t-test or Wilcoxon’s signed-rank test. A p-value < 0.05 was considered statistically significant. Bland–Altman plots and box plots were analyzed. Inter-rater agreement was evaluated using Cohen’s kappa value (κ), with κ interpreted as follows [24]: 0 < κ ≤ 0.2 = slight agreement, 0.2 < κ ≤ 0.4 = fair agreement, 0.4 < κ ≤ 0.6 = moderate agreement, 0.6 < κ ≤ 0.8 = substantial agreement, 0.8 < κ < 1.0 = almost perfect agreement, and κ = 1.0 as perfect agreement. All statistical analysis was performed using MedCalc Statistical software (version 20.218; MedCalc Software Ltd, Ostend, Belgium).
Results
The interval between the initial CTA and additional MRA scans was 7 ± 5 months. The MRA acceptance rate was 42.7% ± 12.4%, leading to total net acquisition times of 08:04 ± 02:52 min. Four patients presented with cardiac arrhythmia during the MRA scan but were not excluded from this study. The observed arrhythmias types were bigeminal ventricular extrasystoles, frequent undefined ventricular extrasystoles, atrial fibrillation, and severe sinus arrhythmia. One patient presented with low voltage and a flattened ECG due to obesity, with repeated trigger failure observed during the scan (190 cm, 150 kg).
The mean CT scan time was 0.90 ± 0.19 s. The median tube voltage was 100 kV (100–120 kV), and the mean tube current was 352.6 ± 88.7 mAs. For arterial phase CT only, the CT dose index volume reached 4.6 ± 2.0 mGy, and the dose length product (DLP) reached 299.3 ± 140 mGy*cm. The DLP almost doubled to 519.1 ± 230.0 mGy*cm for the combined arterial and venous phase.
The final diagnoses are shown in Table 2.
Aortic measurements
No significant difference was found between native MRA and contrast-enhanced CTA for all aortic segments (p = 0.08–0.94). Detailed measurement results are shown in Fig. 1 and Table 3.
Image quality
The visual assessments of general image quality, myocardium, the various aortic segments, and proximal branches showed no significant differences between the two methods (p = 0.07–0.91). Similarly, there was no significant distinction in the evaluation of pulmonary arteries between the two methods (p = 0.05). Both raters favored MRA for the superior and inferior vena cava (IVC; both p < 0.05). The rating of the pulmonary veins was better in the CTA acquisitions (p < 0.05). Inter-rater agreement was at least substantial in all cases (κ > 0.7).
Overall, MRA image quality was downgraded by one point in 4/25 (16%) cases due to uncorrected vessel motion (2/25, 8%) or respiratory motion artifacts (2/25, 8%). We found flow voids in 12/437 (3%) of the systemic arterial segments (aortic segments and branches), 3/25 (12%) of the pulmonary artery segments, and 47/50 (94%) of the systemic venous segments. In 4/25 cases, the MRA images had a “systemic arterial” weighting with low contrast in the pulmonary arteries and systemic veins.
In the four patients with complex ECG findings, the image quality was downgraded in the myocardium (grade 3 in 1/4 cases, grade 4 in 2/4 cases), aortic annulus (grade 4 in 2/4 cases), sinus of Valsalva (grade 4 in 1/4 cases), right and/or left coronary artery (grade 2 in 1/8 cases, grade 3 in 3/8 cases), sinotubular junction and ascending aorta (both grade 4 in 1/4 cases), and pulmonary arteries (grade 2 in 1/4 cases). Otherwise, the image quality was generally excellent.
An excellent fat suppression (score 5) was achieved in 24/25 (96%) cases. One patient had a fat–water swap separating the two body halves.
Overall, CTA image quality was reduced by one point in 4/25 (16%) cases as a result of reduced aortic contrast due to bolus timing (3/25, 12%) and/or off-center artifacts due to patient positioning (2/25, 8%). The infrarenal inferior vena cava was rated with low diagnostic confidence, or worse, in the venous phase images in 12/17 cases (71%) due to insufficient vessel contrast.
Example MRA and CTA images are provided in Figs. 2, 3, 4, 5 and 6, and detailed image quality scores are provided in Table 1.
Discussion
This study evaluated a novel, large field-of-view, highly accelerated, navigator- and ECG-gated 3D native MRA sequence with Dixon water-fat separation. We compared it with a state-of-the-art ECG-triggered aortic CTA provided by a third-generation dual-source scanner.
Despite the relatively long interval of 7 ± 5 months, the diameter and cross-sectional area in the various aortic segments did not differ significantly between the two methods. Most disagreements were < 0.5 mm, consistent with other comparisons of aortic CTA and MRA [25, 26]. Three outliers between 1.5 and 3.0 mm at the level of the sinotubular junction and the diaphragm may have occurred due to discrepancies in the measurement level or true dilatation between the different time points. Nevertheless, these differences are not clinically significant because the threshold growth in current guidelines is 5 mm [2].
Both methods generally delivered excellent image quality. The image quality of the aorta, its branches, and the pulmonary arteries was rated similarly in both modalities. MRA outperformed venous phase CTA for the superior and inferior venae cavae due to lower vascular contrast in the CTA images, particularly in the infrarenal vena cava. Interobserver agreement was at least substantial (κ > 0.7).
With acquisition times of 08:04 ± 02:52 min vs. 0.90 ± 0.19 s, the MRA acquisition was significantly longer than the CTA acquisition. Nevertheless, this acquisition time was comparable to other thoracic aortic MRA studies, which reported acquisition times of 05:56 min to 08:06 min for thoracic aortic MRA alone at a lower resolution of 1.3–1.5 mm3 [18, 27, 28]. The proposed sequence covers a large field of view that includes nearly the entire chest and abdomen, down to the aortic bifurcation, at a higher resolution of 1.2 mm3. This coverage is comparable to CTA as a reference technique and superior to the published results on the thoracic aorta in a parasagittal orientation [29]. The Dixon technique proved to be largely insensitive to magnetic field inhomogeneities, with robust water-fat separation in all but one case. The iterative compressed sensing reconstruction, performed inline on the scanner, took approximately 1 min. All MRA datasets were diagnostic despite the relatively challenging conditions, including patients suffering from arrhythmia and obesity (weight up to 150 kg), and the sequence proved robust for routine clinical scanning.
A similar sequence, modified relaxation-enhanced angiography without contrast and triggering (modified REACT), was previously compared with a non-ECG-gated contrast-enhanced MRA, showing superior image quality from the aortic annulus to the mid-ascending aorta [18]. Compared to 2D steady-state free precession imaging of the aorta, the sequence showed comparable vessel diameters while offering the possibility of 3D reformations [30]. We compared the proposed MRA sequence to state-of-the-art ECG-triggered aortic CTA provided by a third-generation dual-source scanner as the current clinical gold standard in non-invasive aortic imaging.
The proposed MRA sequence is unsuitable for emergencies due to the prolonged scan time and limited patient surveillance during acquisition. In most other cases, we consider it a valuable alternative that avoids exposure to ionizing radiation and contrast agents, especially in patients who undergo regular examinations. Many such patients are young and have congenital aortic defects or diseases such as Marfan syndrome and are, therefore, particularly prone to developing radiation-induced cancer [6]. Conversely, atherosclerotic aortic lesions often co-exist with multisystemic effects, including impaired renal function, which may be potentially exacerbated by iodine-based contrast agents [31]. Moreover, CTA demands high-contrast injection rates of 4–5 mL/s [32], a known risk factor for extravasation [33]. Due to native acquisition, there is no risk of allergic reactions due to contrast agents, which may be especially beneficial for patients with known severe adverse reactions to iodinated or gadolinium-based contrast agents. Patients unable to follow respiratory pauses may also benefit from the robust MRA technique in free breathing. Given its flow independence, all major thoracic and abdominal vessels can be evaluated in a single examination rather than a multiple-scan protocol with a multiple-dose application. This advantage may be particularly beneficial in assessing a complex post-surgery event such as Fontan circulation or atrial and arterial switch operations.
Limitations
This study had some limitations that should be mentioned. First, it excluded patients with aortic implants; studies including this patient cohort should be performed to evaluate the performance of the proposed sequence in the presence of metallic implants. Second, the time interval between the initial clinically indicated CTA and the MRA was relatively long. Third, there was a potential selection bias for more compliant patients due to the relatively low positive response rate of 25 participants out of 83 contacted patients. Fourth, the sample size was relatively small (n = 25). Fifth, the contrast bolus volume in the CTA was optimized for aortic imaging; therefore, the image quality of the systemic veins may have been compromised in the venous phase images. Sixth, image quality was assessed primarily based on subjective scales. Finally, not every hospital has an MRI device, especially at 3 T, while CT devices are much more widespread.
Conclusion
This study’s novel, advanced MRA sequence provides excellent image quality and reliable measurements in routine and challenging patients. It avoids adverse effects such as extravasation, renal insufficiency, and stochastic radiation damage in vulnerable patients with cardiovascular diseases or malformations. The free-breathing technique improves patient compliance. Therefore, it is a perfect tool for repeated follow-up examinations.
Data availability
The data supporting the findings of this study are available upon reasonable request from the corresponding author. However, please note that we cannot make the complete image datasets publicly available since they contain personal information that could compromise the study participants’ privacy and consent.
References
Sampson UKA, Norman PE, Fowkes FGR et al (2014) Global and regional burden of aortic dissection and aneurysms: mortality trends in 21 World Regions, 1990 to 2010. Glob Heart 9:171–180
(2014) 2014 ESC Guidelines on the diagnosis and treatment of aortic diseases: Document covering acute and chronic aortic diseases of the thoracic and abdominal aorta of the adultThe Task Force for the Diagnosis and Treatment of Aortic Diseases of the European Society of Cardiology (ESC). Eur Heart J 35:2873–2926
Turtle EJ, Sule AA, Bath LE et al (2013) Assessing and addressing cardiovascular risk in adults with Turner syndrome. Clin Endocrinol (Oxf) 78:639–645
Baumgartner H, De Backer J, Babu-Narayan SV et al (2021) 2020 ESC Guidelines for the management of adult congenital heart disease. Eur Heart J 42:563–645
Berrington de Gonzalez A, Pasqual E, Veiga L (2021) Epidemiological studies of CT scans and cancer risk: the state of the science. Br J Radiol 94:20210471
Kwee TC, Dijkstra H, Knapen DG et al (2020) Which patients are prone to undergo disproportionate recurrent CT imaging and should we worry? Eur J Radiol 125:108898
Faucon A-L, Bobrie G, Clément O (2019) Nephrotoxicity of iodinated contrast media: From pathophysiology to prevention strategies. Eur J Radiol 116:231–241
Pennig L, Wagner A, Weiss K et al (2020) Imaging of the pulmonary vasculature in congenital heart disease without gadolinium contrast: Intraindividual comparison of a novel Compressed SENSE accelerated 3D modified REACT with 4D contrast-enhanced magnetic resonance angiography. J Cardiovasc Magn Reson 22:8
Bäuerle T, Saake M, Uder M (2021) Gadolinium-based contrast agents: What we learned from acute adverse events, nephrogenic systemic fibrosis and brain retention. ROFO Fortschr Geb Rontgenstr Nuklearmed 193:1010–1018
Kanda T, Ishii K, Kawaguchi H et al (2014) High signal intensity in the dentate nucleus and globus pallidus on unenhanced T1-weighted MR images: relationship with increasing cumulative dose of a gadolinium-based contrast material. Radiology 270:834–841
Choi JW, Moon W-J (2019) Gadolinium deposition in the brain: current updates. Korean J Radiol 20:134–147
Mathur M, Jones JR, Weinreb JC (2020) Gadolinium deposition and nephrogenic systemic fibrosis: a radiologist’s primer. Radiographics 40:153–162
Iyad N, Ahmad SM, Alkhatib SG, Hjouj M (2023) Gadolinium contrast agents- challenges and opportunities of a multidisciplinary approach: literature review. Eur J Radiol Open 11:100503
De Leucio A, De Jesus O (2022) MR Angiogram. In: StatPearls. StatPearls Publishing, Treasure Island (FL)
Morita S, Masukawa A, Suzuki K et al (2011) Unenhanced MR angiography: techniques and clinical applications in patients with chronic kidney disease. Radiogr Rev Publ Radiol Soc N Am Inc 31:E13-33
Shaw JL, Knowles BR, Goldfarb JW et al (2014) Left atrial late gadolinium enhancement with water-fat separation: the importance of phase-encoding order. J Magn Reson Imaging JMRI 40:119–125
Munoz C, Bustin A, Neji R et al (2020) Motion-corrected 3D whole-heart water-fat high-resolution late gadolinium enhancement cardiovascular magnetic resonance imaging. J Cardiovasc Magn Reson Off J Soc Cardiovasc Magn Reson 22:53
Pennig L, Wagner A, Weiss K et al (2021) Comparison of a novel Compressed SENSE accelerated 3D modified relaxation-enhanced angiography without contrast and triggering with CE-MRA in imaging of the thoracic aorta. Int J Cardiovasc Imaging 37:315–329
Zeilinger MG, Wiesmüller M, Forman C et al (2021) 3D Dixon water-fat LGE imaging with image navigator and compressed sensing in cardiac MRI. Eur Radiol 31:3951–3961
Ye JC (2019) Compressed sensing MRI: a review from signal processing perspective. BMC Biomed Eng 1:8
Forman C, Wetzl J, Hayes C, Schmidt M (2016) Compressed sensing: a paradigm shift in MRI. Magnetom Flash 66:9–13
Markl M, Alley MT, Elkins CJ, Pelc NJ (2003) Flow effects in balanced steady state free precession imaging. Magn Reson Med 50:892–903
Saranathan M, Glockner J (2013) Three-dimensional dixon fat-water separated rapid breathheld imaging of myocardial infarction: 3D Fat Suppressed Imaging of Infarction. J Magn Reson Imaging 38:1362–1368
Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174
Yacoub B, Stroud RE, Piccini D et al (2021) Measurement accuracy of prototype non-contrast, compressed sensing-based, respiratory motion-resolved whole heart cardiovascular magnetic resonance angiography for the assessment of thoracic aortic dilatation: comparison with computed tomography angiography. J Cardiovasc Magn Reson 23:7
Goshima S, Kanematsu M, Kondo H et al (2013) Preoperative planning for endovascular aortic repair of abdominal aortic aneurysms: feasibility of nonenhanced MR angiography versus contrast-enhanced CT angiography. Radiology 267:948–955
Correa Londono M, Trussardi N, Obmann VC et al (2021) Radial self-navigated native magnetic resonance angiography in comparison to navigator-gated contrast-enhanced MRA of the entire thoracic aorta in an aortic patient collective. J Cardiovasc Magn Reson 23:94
von Knobelsdorff-Brenkenhoff F, Gruettner H, Trauzeddel RF et al (2014) Comparison of native high-resolution 3D and contrast-enhanced MR angiography for assessing the thoracic aorta. Eur Heart J - Cardiovasc Imaging 15:651–658
Bannas P, Groth M, Rybczynski M et al (2013) Assessment of aortic root dimensions in patients with suspected Marfan syndrome: intraindividual comparison of contrast-enhanced and non-contrast magnetic resonance angiography with echocardiography. Int J Cardiol 167:190–196
Wright F, Warncke M, Sinn M et al (2023) Assessment of aortic diameter in Marfan patients: intraindividual comparison of 3D-Dixon and 2D-SSFP magnetic resonance imaging. Eur Radiol 33:1687–1697
Ellis JH, Khalatbari S, Yosef M et al (2019) Influence of clinical factors on risk of contrast-induced nephrotoxicity from IV iodinated low-osmolality contrast material in patients with a low estimated glomerular filtration rate. AJR Am J Roentgenol 213:W188–W193
Baliyan V, Shaqdan K, Hedgire S, Ghoshhajra B (2019) Vascular computed tomography angiography technique and indications. Cardiovasc Diagn Ther 9:S14-S1S27
Heshmatzadeh Behzadi A, Farooq Z, Newhouse JH, Prince MR (2018) MRI and CT contrast media extravasation: a systematic review. Medicine (Baltimore) 97:e0055
Funding
Open Access funding enabled and organized by Projekt DEAL. The authors declare that no funds, grants, or other support were received during the preparation of this manuscript.
Author information
Authors and Affiliations
Contributions
Conceptualization: DG, CT, MZ; Methodology: CT, MZ; Formal analysis and investigation: CT, MZ; Writing–original draft preparation: RH, CT, MZ; Writing–review and editing: CT, MZ; Resources: SA, FA, DG, RJ, MM, MS; Supervision: CT, MU, MZ.
Corresponding author
Ethics declarations
Competing interests
D.G and M.S. are employees of Siemens Healthcare. Authors who were not employees of or consultants for Siemens had full control of inclusion of any data and information that might present a conflict of interest for the authors who are industry employees. The other authors of this manuscript have no relevant financial or non-financial relationships to disclose.
Ethical approval
This study was performed in line with the principles of the Declaration of Helsinki. Approval was granted by the Ethics Committee of University B (Date 23.03.2021/No. 59_21B).
Consent to participate
Informed consent was obtained from all individual participants included in the study.
Consent to publish
No identifying information about the individual participants is published in the study.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Zeilinger, M.G., Giese, D., Schmidt, M. et al. Highly accelerated, Dixon-based non-contrast MR angiography versus high-pitch CT angiography. Radiol med 129, 268–279 (2024). https://doi.org/10.1007/s11547-023-01752-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11547-023-01752-0