We evaluated blood flow and oxygen metabolism in a patient with Lhermitte–Duclos disease using brain positron emission tomography. The lesion showed increased blood flow, reduced oxygen extraction fraction and normal metabolic rates of oxygen. These findings suggest that lesions of Lhermitte–Duclos disease may constitute hamartoma or hypertrophy rather than neoplasm.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Koch R, Scholz M, Nelen MR, Schwechheimer K, Epplen J, Harders AG: Lhermitte-Duclos disease as a component of Cowden's syndrome. J Neurosurg 90: 776–779, 1999

    Google Scholar 

  2. Kulkantrakorn K, Awwad EE, Levy B, Selhorst JB, Cole HO, Leake D, Gussler JR, Epstein AD, Malik MM: MRI in Lhermitte-Duclos disease. Neurology 48: 725–731, 1997

    Google Scholar 

  3. Tuli S, Provias JP, Bernstein M: Lhermitte-Duclos diseases: literature review and novel treatment strategy. Can J Neurol Sci 24: 155–160, 1997

    Google Scholar 

  4. Coleman RE, Hoffman JM, Hanson MW, Sostman HD, Schold SC: Clinical application of PET for the evaluation of brain tumors. J Nucl Med 32: 616–622, 1991

    Google Scholar 

  5. Strauss LG, Conti PS: The applications of PET in clinical oncology. J Nucl Med 32: 623–650, 1991

    Google Scholar 

  6. Mineura K, Yasuda T, Kowada M, Ogawa T, Shishido F, Uemura K: Positron emission tomographic evaluation of radiochemotherapeutic effect on regional cerebral hemocirculation and metabolism in patients with gliomas. J Neuro-Oncol 5: 277–285, 1987

    Google Scholar 

  7. Ito M, Lammertsma AA, Wise RJ, Bernardi S, Frackowiak RS, Heather JD, McKenzie CG, Thomas DG, Jones T: Measurement of regional cerebral blood flow and oxygen utilisation in patients with cerebral tumours using 15-O and positron emission tomography: analytical techniques and preliminary results. Neuroradiology 23: 63-74, 1982

    Google Scholar 

  8. Mineura K, Sasajima T, Kowada M, Ogawa T, Hatazawa J, Shishido F, Uemura K: Perfusion and metabolism in predicting the survival of patients with cerebral gliomas. Cancer 73: 2386–2394, 1994

    Google Scholar 

  9. Ogasawara K, Yasuda S, Beppu T, Kobayashi M, Doi M, Kuroda K, Ogawa A: Brain PET and technetium-99m-ECD SPECT imaging in Lhermitte-Duclos disease. Neuroradiology (in press)

  10. Iida H, Miura S, Kanno I, Murakami M, Takahashi K, Uemura K, Hirose Y, Amano M, Yamamoto S, Tanaka K: Design and evaluation of Headtome IV, a whole-body positron emission tomograph. IEEE Trans Nucl Sci 37: 1006–1010, 1989

    Google Scholar 

  11. Hatazawa J, Fujita H, Kanno I, Satoh T, Iida H, Miura S, Murakami M, Okudera T, Inugami A, Ogawa T: Regional cerebral blood flow, blood volume, oxygen extraction fraction and oxygen utilization rate in normal volunteers measured by the autoradiographic technique and the single breath inhalation method. Ann Nucl Med 9: 15–21, 1995

    Google Scholar 

  12. Lammertsma AA, Wise RJ, Cox TC, Thomas DG, Jones T: Measurement of blood flow, oxygen utilisation, oxygen extraction ratio, and fractional blood volume in human brain tumours and surrounding oedematous tissue. Br J Radiol 58: 725–734, 1985

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ogasawara, K., Beppu, T., Yasuda, S. et al. Blood Flow and Oxygen Metabolism in a Case of Lhermitte–Duclos Disease: Results of Positron Emission Tomography. J Neurooncol 55, 59–61 (2001). https://doi.org/10.1023/A:1012953800208

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1012953800208

Navigation