Skip to main content
Log in

Realization, Operation and Results of the Multichannel Far-Infrared Polarimeter on RFX

  • Published:
International Journal of Infrared and Millimeter Waves Aims and scope Submit manuscript

Abstract

This paper illustrates the realisation and testing of the multichannel far-infrared polarimeter for the RFX machine, a plasma confinement experiment with the Reversed Field Pinch configuration. The diagnostic is described and the its main sections are outlined: the laser system operating at λ = 118.8μm, the FIR optical line, the beam splitter and the beam detection units, the signal processing electronics and the motion electronics for the calibration halfwave plates. Emphasis is placed on the work performed on the polarimeter to make it operational. We illustrate the preliminary tests of the diagnostic equipment and the activity performed to bring the diagnostic into reliable operation, in particular the reduction of the noise produced by magnetically induced mechanical vibrations during machine shots. An example of the first Faraday angle measurements performed on five chords are presented and discussed. The measured Faraday angle was also compared to a theoretically calculated value, based on a simple plasma model, with satisfactory agreement between measured and predicted data.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. G. Rostagni, Fusion Eng. Des. 25 (1995) 301.

    Google Scholar 

  2. A. Buffa and E. Zilli, Istituto Gas Ionizzati, Internal Report 88/04 (1988).

  3. A. Buffa, P. Innocente, S. Martini, M. Moresco, E. Spada and E. Zilli, Proceedings of the 16th European Conference on Controlled Fusion and Plasma Physics, Venice, Italy, 1989, (European Physical Society), Part IV, p.1493.

  4. P. Innocente, S. Martini and E. Zilli, Istituto Gas Ionizzati, Internal Report 91/02 (1991).

  5. E. Zilli, Istituto Gas Ionizzati, Internal Report 90/01 (1990).

  6. E. Zilli, “Diagnostics for Contemporary Fusion Experiments”, Proceedings of the International School of Plasma Physics, Varenna, Italy, 1991 (Editrice Compositori, Bologna), p. 633.

    Google Scholar 

  7. S. L. Prunty, M.C. Sexton and E. Zilli, Int. J. Infrared and Millimetre Waves 12, 591, (1992).

    Google Scholar 

  8. M. Bagatin et al., Fus. Eng. Design 25 (1995) 425.

    Google Scholar 

  9. G. Gadani et al., Rev. Sci. Instrum. 66 (1995) 4613.

    Google Scholar 

  10. L. Giudicotti, et al., Proceedings of the 8th International Symposium on “Laser-Aided Plasma Diagnostics”, Doorwerth, The Netherlands, (1997), 293.

    Google Scholar 

  11. P. Innocente and S. Martini, Rev. Sci. Instrum. 63 (1992) 4996.

    Google Scholar 

  12. M. Moresco, R. O'Dubhghaill and E. Spada, Int. J. Infrared and Millimetre Waves 12 (1992) 609.

    Google Scholar 

  13. E. Marcolin, F. Milani, I. Molon, E. Zilli, Istituto Gas Ionizzati, Consorzio RFX Internal Report IGI 98/01, (1998).

  14. E. H. Putley, The Pyroelectric Detector, from “Semiconductors and Semimetals”, R.K. Willardson and A.C. Beer Eds., Academic Press, N.Y., Vol. 5, (1970), pp.259-285.

    Google Scholar 

  15. M. Breda, et al. Istituto Gas Ionizzati, Consorzio RFX Internal Report IGI 2000/01, (2000).

  16. S. Ortolani, Course on Mirror-based and Field-Reversed Approaches to Magnetic Fusion, International School of Plasma Physics, Varenna, Italy, 1983 (Monotypia Franchi, Città di Castello, Perugia, Italy, 1983), Vol.II, p.513.

    Google Scholar 

  17. H. Soltwisch, Nucl.Fusion 23,(1983) 1681.

    Google Scholar 

  18. P. Martin, et al. Phys.Plasmas 7, 1984 (2000)

    Google Scholar 

  19. P. Zanca, S. Martini, Plasma Phys. Control Fusion 41 (1999) 1251

    Google Scholar 

  20. A. Buffa et al.: Proceedings of the 21st European Conference on Controlled Fusion and Plasma Physics, Montpellier, France, 1994, (European Physical Society), Part II, p.458.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Zilli, E., O'Gorman, M., Giudicotti, L. et al. Realization, Operation and Results of the Multichannel Far-Infrared Polarimeter on RFX. International Journal of Infrared and Millimeter Waves 21, 1673–1696 (2000). https://doi.org/10.1023/A:1006624012176

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1006624012176

Keywords

Navigation