Assessment of coronary blood flow in humans using phase difference MR imaging

  • Published:
The International Journal of Cardiac Imaging Aims and scope Submit manuscript

Abstract

Coronary blood flow quantification provides essential information on the hemodynamic significance of coronary artery stenoses. Recently, magnetic resonance (MR) flow mapping has emerged as a new promising method to noninvasively determine flow velocity and flow volume within the coronary arteries. The aim of this study was to compare phase difference (PD) MR flow quantification with intracoronary Doppler flow measurements in 15 patients with suspected or known coronary artery disease. Flow quantification was attempted before and after systemic application of 5mg Isosorbiddinitrate (ISDN) in order to determine possible alterations in coronary flow volume. PD MR flow mapping was performed successfully in 13 of the 15 patients. For flow velocities and flow volume values, a close correlation between PD MR and Doppler flow measurements was found (r = 0.79 and r = 0.90, respectively). However, average flow measured by PD MR was significantly lower than the invasively obtained values (9.0 ± 4.4 cm/sec vs. 11.7 ± 4.9 cm/sec; p<0.001 and 46.3 ± 28.7 ml/min vs. 53.4 ± 32.8 ml/min; p<0.05). Although the mean flow volume remained constant in the entire patient group after ISDN application, individual changes (increase in 6, decrease in 4 cases) could be documented with PD MR imaging and showed a good correlation to the Doppler method (r = 0.82). In conclusion, PD MR flow mapping is a promising method for the noninvasive quantification of coronary blood flow and therefore offers the potential of assessing coronary artery stenoses. However, technical improvements are mandatory in order to increase accuracy of the method.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Gould KL, Lipscomb K, Hamilton GW. Physiologic basis for assessing critical coronary stenosis: instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve. Am J Cardiol 1974; 33: 87-94.

    Google Scholar 

  2. White CW, Wright CB, Doty DB, Hiratza LF, Eastham CL, Harrison DG, Marcus ML. Does visual interpretation of the coronary angiogram predict the physiological importance of a coronary stenosis? N Engl J Med 1984; 310: 819-25.

    Google Scholar 

  3. Tron C, Kern MJ, Donohue TJ, Bach RG, Aguirre FV, Caracciolo EA, Moore JA. Comparison of quantitative angiographically derived and measured translesion pressure and flow velocity in coronary artery disease. Am J Cardiol 1995; 75: 111-7.

    Google Scholar 

  4. Donohue TJ, Kern MJ, Aguirre FV, Bach RG, Wolford D, Bell CA, Segal J. Assessing the hemodynamic significance of coronary artery stenoses: analysis of translesional pressure-flow velocity relations in patients. J Am Coll Cardiol 1993; 22: 449-58.

    Google Scholar 

  5. Edelman RR, Manning WJ, Gervino E, Li W. Flow velocity quantification in human coronary arteries with fast, breath-hold MR angiography. JMRI 1993; 3: 699-703.

    Google Scholar 

  6. Poncelet BP, Weisskoff RM, Wedeen VJ, Brady TJ, Kantor H. Time of flight quantification of coronary flow with echoplanar MRI. Magn Reson Med 1993; 30: 447-57.

    Google Scholar 

  7. Clarke GD, Eckels R, Chaney C, Smith D, Dittrich J, Hundley WG, NessAiver M, Li HF, Parkey RW, Peshock RM. Measurement of absolute epicardial coronary artery flow and flow reserve with breath-hold cine phase-contrast magnetic resonance imaging. Circulation 1995; 91: 2627-34.

    Google Scholar 

  8. Hundley WG, Lange RA, Clarke GD, Meshack BM, Payne J, Landau C, McColl R, Sayad DE, Willet DL, Willard JE, Hillis LD, Peshock RM. Assessment of coronary flow and flow reserve in humans with magnetic resonance imaging. Circulation 1996; 93: 1502-8.

    Google Scholar 

  9. Hofman MB, van Rossum AC, Sprenger M, Westerhof N. Assessment of flow in the right human coronary artery by magnetic resonance phase contrast velocity measurement: effects of cardiac and respiratory motion. Magn Reson Med 1996; 35: 521-31.

    Google Scholar 

  10. Sakuma H, Blake LM, Amidon TM, O'Sullivan M, Szolar DH, Furber AP, Bernstein MA, Foo TK, Higgins CB. Coronary flow reserve: noninvasive measurement in humans with breath-hold velocity-encoded cine MR imaging. Radiology 1996; 198: 745-50.

    Google Scholar 

  11. Davis CP, Liu PF, Hauser M, Gohde SC, von Schulthess GK, Debatin JF. Coronary flow and coronary flow reserve measurements in humans with breath-held magnetic resonance phase contrast velocity mapping. Magn Reson Med 1997; 37: 537-44.

    Google Scholar 

  12. Grist TM, Polzin JA, Bianco JA, Foo TK, Bernstein MA, Mistretta CM. Measurement of coronary blood flow and flow reserve using magnetic resonance imaging. Cardiology 1997; 88: 80-9.

    Google Scholar 

  13. Hoogendoorn, LI, Pattynama PMT, Buis B, van der Geest RJ, van der Wall EE, de Roos A.. Noninvasive evaluation of aorto-coronary bypass grafts with magnetic resonance flow mapping. Am J Cardiol 1995; 75: 845-8.

    Google Scholar 

  14. Galjee MA, van Rossum AC, Doesburg T, van Eenige Mj, Visser CA. Value of magnetic resonance imaging in assessing patency and function of coronary artery bypass grafts. An angiographically controlled study. Circulation 1996; 93: 660-6.

    Google Scholar 

  15. Davis K, Kennedy JW, Kemp HG, Judkins MP, Gosselin AJ, Killip T. Complications of coronary arteriography from the collaborative study of coronary artery surgery (CASS). Circulation 1979; 59: 1105-12.

    Google Scholar 

  16. Kennedy JW, Baxley WA, Bunnel IL, Gensini GG, Messer JV, Mudd JG, Noto TJ, Paulin S, Pichard AD, Sheldon WL, Cohen M. Mortality related to cardiac catheterization and angiography. Cathet Cardiovasc Diagn 1982; 8: 323-40.

    Google Scholar 

  17. Mehta J, Pepine CJ. Effect of sublingual nitroglycerin on regional flow in patients with and without coronary disease. Circulation 1978; 58: 803-7.

    Google Scholar 

  18. Cohn PF, Maddox D, Holman BL, Markis JE, Adams DF, See JR, Idoine J. Effect of sublingually administered nitroglycerin on regional myocardial blood flow in patients with coronary artery disease. Am J Cardiol 1977; 39: 672-8.

    Google Scholar 

  19. Simon R, Amende I, Lichtlen PR. Effects of Nitroglycerin on blood velocity and flow in coronary arteries and bypass grafts in man. In: Lichtlen PR, Engel HJ, Schrey A, et al, (eds). Nitrates III. Berlin - Heidelberg-New York: Springer, 1981: 202-8.

    Google Scholar 

  20. Simonetti I, Rossen JD, Winniford MD, Marcus ML. Biphasic effect of nitroglycerin on coronary hemodynamics in normal subjects. Z Kardiol 1989; 78 Suppl 2: 52-5.

    Google Scholar 

  21. Chen J-S, Hwang C-L, Wang K-Y, Chen Y-T. Comparison of the effects of nifedipine and nitroglycerin on coronary blood flow using intracoronary Doppler catheter. J Formos Med Assoc 1994; 93: 457-61.

    Google Scholar 

  22. Edelman RR, Manning WJ, Burstein D, Paulin S. Coronary arteries: breath-hold MR angiography. Radiology 1991; 181: 641-3.

    Google Scholar 

  23. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-10.

    Google Scholar 

  24. Chien D, Saloner D, Anderson C. Breath-hold velocity measurements of the coronary arteries by MR bolus tagging with segmented acquisitions. Proceedings of the Second SMR Meeting; 1994 Aug 612; San Francisco. Berkeley: Society of Magnetic Resonance, 1994.

    Google Scholar 

  25. Wolf R, Ehrman R, Riederer S, Rossman P. Analysis of systematic and random error in MR volumetric flow measurements. Magn Reson Med 1993; 30: 82-91.

    Google Scholar 

  26. Tang C, Blatter DD, Parker DL. Accuracy of phase-contrast measurements in the presence of partial volume effects. JMRI 1993; 3: 377-85.

    Google Scholar 

  27. Polzin JA, Korosec FR, Wedding KL, Grist TM, Frayne R, Peters DC, Mistretta CA. Effects of through-plane myocardial motion on phase-difference and complex-difference measurements of absolute coronary artery flow. JMRI 1996; 1: 113-23.

    Google Scholar 

  28. Clarke GD, Hundley WG, Mc Coll RW, Eckels R, Smith D, Chaney C, Li HF, Peshock RM. Velocity encoded, phase-difference cine MRI measurements of coronary flow: dependence of flow accuracy on the number of cine frames, JMRI 1996; 6: 733-42.

    Google Scholar 

  29. Miller DD, Donohue TJ, Younis LT, Bach RG, Aguirre FV, Wittry MD, Goodgold HM, Chaitman BR, Kern MJ. Correlation of pharmacologic 99mTc-sestamibi myocardial perfusion imaging with poststenotic coronary flow reserve in patients with angiographically intermediate coronary artery stenoses. Circulation 1994; 89: 2150-60.

    Google Scholar 

  30. Joye JD, Schulman DS, Lasorda D, Farah T, Donohue BC, Reichek N. Intracoronary Doppler guide wire versus stress single-photon emission computed tomographic thallium-201 imaging in assessment of intermediate coronary stenoses. J Am Coll Cardiol 1994; 24: 940-7.

    Google Scholar 

  31. Foo TK, Bernstein MA, Aisen AM, Hernandez RJ, Collick BD, Bernstein T. Improved ejection fraction and flow velocity estimates with use of view sharing and uniform repetition time excitation with fast cardiac techniques. Radiology 1995; 195: 471-8.

    Google Scholar 

  32. Manning WJ, Li W, Edelman RR. A preliminary report comparing magnetic resonance coronary angiography with conventional angiography. N Engl J Med 1993; 328: 828-32.

    Google Scholar 

  33. Duerinckx AJ, Urman MK. Two-dimensional coronary MR angiography: analysis of initial clinical results. Radiology 1994; 193: 731-8.

    Google Scholar 

  34. Post JC, van Rossum AC, Hofman MB, Valk J, Visser CA. Three-dimensional respiratory-gated MR angiography of coronary arteries: Comparison with conventional coronary angiography. AJR 1996; 166: 1399-1404.

    Google Scholar 

  35. Kessler W, Achenbach S, Moshage W, Zink D, Kroeker R, Nitz W, Laub G, Bachmann K. Usefulness of respiratory gated magnetic resonance coronary angiography in assessing narrowings ≥50% in diameter in native coronary arteries and in aortocoronary bypass conduits. Am J Cardiol 1997; 80: 989-93.

    Google Scholar 

Download references

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Nitz, W., Laub, G. Assessment of coronary blood flow in humans using phase difference MR imaging. Int J Cardiovasc Imaging 14, 179–186 (1998). https://doi.org/10.1023/A:1005976705707

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1005976705707

Navigation