On-line membrane extraction microtrap (OLMEM) gas chromatography was used for continuous monitoring of volatile organic compounds (VOCs) in water. The aqueous sample flowed through tubular membrane and the VOCs selectively permeated through it. The permeated VOCs were stripped by a carrier gas and transported to a microtrap. The microtrap retained and concentrated the analytes before injecting into a GC. In this study, the performance of a composite membrane was compared with that of a conventional silicone membrane. The advantages of using the composite membrane were higher extraction efficiency and shorter response time. Extraction efficiencies as high as 95% were obtained for compounds such as toluene and trichloroethane.
Similar content being viewed by others
References
Bauer, S. and Solyom, D.: 1994, Anal. Chem., 66, 4422.
Cheryan, M.: 1968, Ultrafiltration Handbook, Technomic Publishing Company, Inc., Chapter 2, p.27
Favre, E., Schaetzel, P., Nguygen, Q.T., Clement, R. and Neel, J.: 1994, J. of Membrane Sci., 92, 169.
Ho, W.S.W. and Sirkar, K.K.: 1992, Membrane Handbook, Van Nostrand Reinhold, New York, Chapter 8, p.117,.
Ji, W., Sikdar, S.K.and Hwang, S.-T.: 1994, J. Membrane Sci., 93, 1.
Kotiaho, T., Lauritsen, F.R., Choudhury, T.K., Cooks, R.G. and Tsao, G.T.: 1991, Anal. Chem., 63, 875A.
Lapack M.A. and You, J.C.: 1991, Anal. Chem., 63, 1631.
Melcher, R.G. and Morabito, P.L.: 1990, Anal. Chem., 62, 2183.
Mitra, S. and Chen, Y.: 1993, J. Chromatogr., 648, 415.
Mitra, S. and Lai, A.: 1995, J. Chromatogr. Sci. 33, 285.
Mitra, S., Zhu, N. and Zhang, X.: 1995a, “Continuous Monitoring Of Volatile Organic Compounds In Air Emissions Using On-Line Membrane Extraction Microtrap GC System” J. Chromatogr. (submitted)
Mitra, S., Zhang, L., Zhu, N. and Guo, X.: 1995b, “Characteristics of On-line Membrane Extraction Microtrap GC System as Applied to Air and Water Monitoring” J. Microcolumn Separations (submitted).
Nguyen, Q.T., Ninow, J.L. and Marc, I.: 1991, J. Membrane Sci., 59, 249.
Parthasarathy, A., Brumlik, C.J., Martin, J.R. and Collins, G.E.: 1994, J. Membrane Sci., 94, 249.
Pratt, K.F. and Pawliszyn, J.: 1992, Anal. Chem., 64, 2101.
Ruckenstein, E. and Sun, F.: 1994, J. Membrane Sci., 95, 207.
Silivon, L.E., Bauer, M.R., Ho, A.S. and Budde, W.L.: 1991, Anal. Chem., 63, 1335.
Stern, S.A.: 1994, J. Membrane Sci., 94, 1.
Watson, J.M. and Payue, P.A.: 1990, J. Membrane Sci., 49, 171.
Xu, Y. and Mitra, S.: 1994, J. Chromatogr., 688, 171.
Yamaguchi, T., Yamahara, S., Nakao, S. and Kimura, S.: 1994, J. Membrane Sci., 95, 39.
Yang, M.J., Harms, S., Luo, Y.Z. and Pawliszyn, J.: 1994: Anal. Chem., 66, 1339.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Zhang, L., Guo, X. & Mitra, S. Using a Composite Membrane for Enhanced Sensitivity and Faster Response in On-line Membrane Extraction Microtrap Gas Chromatography. Environ Monit Assess 44, 529–540 (1997). https://doi.org/10.1023/A:1005711027503
Issue Date:
DOI: https://doi.org/10.1023/A:1005711027503