Abstract
The confidence in an individual measurement is the most important factor when selecting the elemental formula candidates from the list of possible elemental compositions following an exact mass measurement. It is the single mass measurement capability rather than the averaged mass measurement potential of the mass spectrometer that is the critical factor when validating the exact mass measurements of small molecules. Here, an experimental protocol has been established to determine the frequency of exact mass measurement by Fourier transform ion cyclotron resonance mass spectrometry (FT-ICRMS) at known relative ion abundance ratios (RA). This in turn allows for statements about the confidence limit for any single exact mass measurement to be made. This is particularly crucial for a high throughput, automated environment where operator intervention is required to be minimal and repeat analyses are to be avoided. The relative ion abundance calculations are essential to determine the working ranges for specific sample ion abundances. Further, it has been shown that if the sample ion abundance is low, then the ion abundance range for the calibration file does not need to be exactly or closely matched, again benefiting the high throughput application.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Beynon, J. H. High Resolution Mass Spectrometry of Organic Materials. Adv. Mass. Spectrom. 1959,, 328–354.
Guidelines to Authors. J. Org. Chem.
Marshall, A. G. Scaling MS Plateaus with High-Resolution FT-ICRMS. Anal. Chem. 2002, 74(9), 253A-259A
Marshall, A. G.; Hendrickson, C. L.; Jackson, G. S. Fourier Transform Ion Cyclotron Resonance Mass Spectrometry; A Primer. Mass Spectrom. Rev. 1998, 17, 1–35.
Zhang, L.-K.; Rempel, D.; Pramanik, B. N.; Gross, M. L. Accurate Mass Measurements by Fourier Transform Mass Spectrometry. Mass Spectrom. Rev. 2005, 24, 286–309.
Bristow, A. W. T.; Webb, K. S. Intercomparison Study on Accurate Mass Measurement of Small Molecules in Mass Spectrometry. J. Am. Soc. Mass Spectrom. 2003, 14, 1086–1098.
Dykes, S.; Fancy, S.-A.; Perkins, G. L.; Pullen, F. S. The Automation of a Commercial Fourier Transform Mass Spectrometer to Provide a Quick and Robust Method for Determining Exact Mass for the Synthetic Chemist. Eur. J. Mass. Spectrom 2003, 9, 80–73.
Taylor, P. K.; Amster, I. J. Space Charge Effects on Mass Accuracy for Multiply-Charged Ions in FT-ICR. Int. J. Mass Spectrom. 2003, 222, 351–361.
Price, P. C.; Gale, P. J.; Loo, J. A.; Heller, D. N.; Richardson, S. D.; Duncan, M. W. ASMS Guidelines for Exact Mass Measurement and Elemental Composition—New Perspectives. Proceedings of the 50th Annual Conference on Mass Spectrometry and Allied Topics; Orlando, FL, 2002.
Author information
Authors and Affiliations
Corresponding author
Additional information
Published online May 25, 2005
Rights and permissions
About this article
Cite this article
Herniman, J.M., Langley, G.J., Bristow, T.W.T. et al. The validation of exact mass measurements for small molecules using FT-ICRMS for improved confidence in the selection of elemental formulas. J Am Soc Mass Spectrom 16, 1100–1108 (2005). https://doi.org/10.1016/j.jasms.2005.02.027
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1016/j.jasms.2005.02.027