Skip to main content
Log in

Adenosine coronary vasodilation quantitative technetium 99m methoxy isobutyl isonitrile myocardial tomography in the identification and localization of coronary artery disease

  • Original Articles
  • Published:
Journal of Nuclear Cardiology Aims and scope

Abstract

Background

Exercise and dipyridamole 99mTc-labeled methoxy isobutyl isonitrile (MIBI) myocardial scintigraphy have been widely used for the diagnosis of coronary artery disease (CAD). However, only limited data on adenosine 99mTc-labeled MIBI cardiac imaging are currently available. This study was designed to assess the accuracy of quantitative adenosinerest 99mTc-labeled MIBI tomography in the diagnosis and localization of CAD.

Methods and Results

Fifty-seven consecutive patients with suspected CAD who underwent coronary angiography and 22 normal volunteers were studied. All patients underwent 99mTc-labeled MIBI tomography after administration of adenosine (140 μg/kg intravenously for 6 minutes) and at rest. A total of 171 vascular coronary territories were analyzed quantitatively. All patients with CAD (≥50% luminal stenosis) (n=55) had abnormal 99mTc-labeled MIBI tomograms. The normalcy rate was 86% by quantitative analysis. Overall sensitivity, specificity, and diagnostic accuracy for detection of individual stenosed vessels were 84%, 87%, and 85%, respectively. In patients with one-vessel CAD (n=24), sensitivity and diagnostic accuracy in the detection of individual stenosed vessels were significantly (p<0.05) higher compared with patients with multivessel CAD (n=31). Moreover, 75% of patients with one-vessel disease showed a scintigraphic pattern characterized by the presence of perfusion defects in only one coronary artery territory, and 74% of patients with multivessel disease showed a scintigraphic pattern characterized by the presence of perfusion defects in two or more coronary artery territories. Sensitivity, specificity, and diagnostic accuracy for detecting individual diseased vessels were similar in patients without previous myocardial infarction (n=18) compared with those with previous myocardial infarction (n=39). In myocardial territories related to noninfarcted areas (n=124), sensitivity and specificity in the detection of stenosed vessels were 75% and 88%. In infarcted areas (n=47), sensitivity and specificity in the detection of stenosed vessels were 98% and 80% (differences not significant vs noninfarcted areas).

Conclusions

Adenosine-controlled coronary vasodilation combined with quantitative 99mTc-labeled MIBI tomography is accurate for identifying patients with CAD and localizing individual stenosed coronary arteries.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Verani MS, Mahmarian JJ, Hixson JB, Boyce TM, Staudacher RA. Diagnosis of coronary artery disease by controlled coronary vasodilation with adenosine and thallium-201 scintigraphy in patients unable to exercise. Circulation 1990;82:80–7.

    PubMed  CAS  Google Scholar 

  2. Nguyen T, Heo J, Ogilby MD, Iskandrian AS. Single photon emission computed tomography with thallium-201 during adenosine-induced coronary hyperemia: correlation with coronary arteriography, exercise thallium imaging and two-dimensional echocardiography. J Am Coll Cardiol 1990;16:1375–83.

    PubMed  CAS  Google Scholar 

  3. Iskandrian AS, Heo J, Nguyen T, et al. Assessment of coronary artery disease using single-photon emission computed tomography with thallium-201 during adenosine-induced coronary hyperemia. Am J Cardiol 1991;67:1190–4.

    Article  PubMed  CAS  Google Scholar 

  4. Zohgby WA. Use of adenosine echocardiography for diagnosis of coronary artery disease. Am Heart J 1991;122:285–92.

    Article  Google Scholar 

  5. Gupta NC, Esterbrooks DJ, Hilleman DE, Mohiuddin SM. Comparison of adenosine and exercise thallium-201 single photon emission computed tomography (SPECT) myocardial perfusion imaging. J Am Coll Cardiol 1992;19:248–57.

    Article  PubMed  CAS  Google Scholar 

  6. Coyne EP, Belvedere DA, Vande Streek PR, Weiland FL, Evans RB, Spaccavento LJ. Thallium-201 scintigraphy after intravenous infusion of adenosine compared with exercise thallium testing in the diagnosis of coronary artery disease. J Am Coll Cardiol 1991;17:1289–2894.

    PubMed  CAS  Google Scholar 

  7. Nishimura S, Mahmarian JJ, Boyce TM, Verani MS. Equivalence between adenosine and exercise thallium-201 myocardial tomography: a multicenter, prospective, crossover trial. J Am Coll Cardiol 1992;20:265–75.

    Article  PubMed  CAS  Google Scholar 

  8. Berman DS. Technetium-99m myocardial perfusion imaging agents and their relations to thallium-201. Am J Cardiol 1990;66:1E-4E.

    Article  PubMed  CAS  Google Scholar 

  9. Wackers FJ, Berman DS, Maddahi J, et al. Technetium-99m hexakis 2-methoxyisobutyl isonitrile: human biodistribution, dosimetry, safety and preliminary comparison to thallium-201 for myocardial perfusion imaging. J Nucl Med 1989;30:301–11.

    PubMed  CAS  Google Scholar 

  10. Kiat H, Maddahi J, Roy LT, Friedman J, Resser K, Berman DS. Comparison of technetium-99m methoxy isobutyl isonitrile with thallium-201 for evaluation of coronary artery disease by planar and tomographic methods. Am Heart J 1989;117:1–11.

    Article  PubMed  CAS  Google Scholar 

  11. Kahn JK, McGhie I, Akers MS, et al. Quantitative rotational tomography with Tl-201 and Tc-99m-2-methoxy-isobutyl-isonitrile: a direct comparison in normal individuals and patients with coronary artery disease. Circulation 1989;79:1289–93.

    Google Scholar 

  12. Iskandrian AS, Heo J, Kong B, Lyons E, Marsch S. Use of technetium-99m isonitrile (RP-30A) in assessing left ventricular perfusion and function at rest and during exercise in coronary artery disease, and comparison with coronary arteriography and exercise thallium-201 SPECT imaging. Am J Cardiol 1989;64:270–5.

    Article  PubMed  CAS  Google Scholar 

  13. West DJ, Najm YC, Mistry R, Clarke SE, Fogelman I, Maisey MN. The localization of myocardial ischaemia with technetium-99m methoxy isobutyl isonitrile and single photon emission computed tomography. Br J Radiol 1989;62:303–13.

    PubMed  CAS  Google Scholar 

  14. Tartagni F, Dondi M, Limonetti P, et al. Dipyridamole technetium-99m-2-methoxy isobutyl isonitrile tomoscintigraphic imaging for identifying diseased coronary vessels: comparison with thallium-201 stress-rest study. J Nucl Med 1991;32:369–76.

    PubMed  CAS  Google Scholar 

  15. Cuocolo A, Santomauro M, Pace L, et al. Comparison between exercise and trans-oesophageal atrial pacing in patients with coronary artery disease: technetium-99m sestamibi simultaneous evaluation of ventricular function and myocardial perfusion. Eur J Nucl Med 1992;19:119–24.

    Article  PubMed  CAS  Google Scholar 

  16. Cuocolo A, Soricelli A, Pace L, et al. Adenosine technetium-99m-methoxy isobutyl isonitrile myocardial tomography in patients with coronary artery disease: comparison with exercise. J Nucl Med 1994;35:1110–5.

    PubMed  CAS  Google Scholar 

  17. Miller DD, Donohue TJ, Younis LT, et al. Correlation of pharmacological Tc-99m sestamibi myocardial perfusion imaging with poststenotic coronary flow reserve in patients with angiographically intermediate coronary artery stenoses. Circulation 1994;89:2150–60.

    PubMed  CAS  Google Scholar 

  18. Diamond GA, Forrester JS. Analysis of probability as an aid in the clinical diagnosis of coronary artery disease. N Engl J Med 1979;300:1350–8.

    PubMed  CAS  Google Scholar 

  19. Austen WG, Edwards JE, Frye RL, et al. A reporting system on patients evaluated for coronary artery disease: report of the ad hoc committee for grading of coronary artery disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 1975;51:7–34.

    Google Scholar 

  20. Borrello JA, Clinthorne NH, Rogers WL, Thrall JH, Keyes JW. Oblique-angle tomography: a reconstructing algorithm for transaxial tomographic data. J Nucl Med 1981;22:471–3.

    PubMed  CAS  Google Scholar 

  21. Cuocolo A, Soricelli A, Nicolai E, et al. Technetium-99m tetrofosmin regional myocardial uptake at rest: relation to severity of coronary artery stenosis in previous myocardial infarction. J Nucl Med 1995;36:907–13.

    PubMed  CAS  Google Scholar 

  22. Mahmarian JJ, Verani MS. Exercise thallium-201 perfusion scintigraphy in the assessment of ischemic heart disease. Am J Cardiol 1991;67:2D-11D.

    Article  PubMed  CAS  Google Scholar 

  23. Verani MS. Myocardial perfusion imaging versus two-dimensional echocardiography: comparative value in the diagnosis of coronary artery disease. J Nucl Cardiol 1994;1:399–414.

    Article  PubMed  CAS  Google Scholar 

  24. De Pasquale EE, Nody AC, DePuey EG, et al. Quantitative rotational thallium-201 tomography for identifying and localizing coronary artery disease. Circulation 1988;77:316–27.

    Google Scholar 

  25. Goldstein RA, Kirkeeide RL, Demer LL, et al. Relationship between geometric dimensions of coronary artery stenosis and myocardial perfusion reserve in man. J Clin Invest 1987;79: 1473–8.

    Article  PubMed  CAS  Google Scholar 

  26. Zijlstra F, van Ommeren J, Reiber JHC, Serruys PW. Does quantitative assessment of coronary artery dimensions predict the physiological significance of a coronary stenosis? Circulation 1987;75:1154–61.

    PubMed  CAS  Google Scholar 

  27. Gould KL. Noninvasive assessment of coronary stenoses by myocardial perfusion imaging during pharmacologic coronary vasodilatation. I: physiologic basis and experimental validation. Am J Cardiol 1978;41:267–78.

    Article  PubMed  CAS  Google Scholar 

  28. Glover DK, Okada RD. Myocardial kinetics of Tc-99m MIBI in canine myocardium after dipyridamole. Circulation 1990; 81:628–36.

    PubMed  CAS  Google Scholar 

  29. Leppo JA, Meerdink DJ. Comparison of the myocardial uptake of a technetium-labeled isonitrile analogue and thallium. Circ Res 1989;65:632–9.

    PubMed  CAS  Google Scholar 

  30. Glover DK, Ruiz M, Edwards NC, et al. Comparison between Tl-201 and Tc-99m sestamibi uptake during adenosine-induced vasodilatation as a function of coronary stenosis severity. Circulation 1995;91:813–20.

    PubMed  CAS  Google Scholar 

  31. Gould KL, Kelley KO. Experimental validation of quantitative coronary arteriography for determining pressure-flow characteristics of coronary stenosis. Circulation 1982;66:930–7.

    PubMed  CAS  Google Scholar 

  32. Marcus ML, Skorton DJ, Johnson MR, et al. Visual estimates of percent diameter coronary stenosis: “a battered gold standard”. J Am Coll Cardiol 1988;11:882–8.

    PubMed  CAS  Google Scholar 

  33. Marcus ML, Harrison DG, White CH, et al. Assessing the physiological significance of coronary obstruction in patients: importance of diffuse, undetected atherosclerosis. Progr Cardiovasc Dis 1988;31:39–56.

    Article  CAS  Google Scholar 

  34. Rocco TP, Dilsizian V, McKusick KA, Fishman AJ, Boucher CA, Strauss HW. Comparison of thallium redistribution with rest “reinjection” imaging for the detection of viable myocardium. Am J Cardiol 1990;66:158–63.

    Article  PubMed  CAS  Google Scholar 

  35. Schelbert HR. Myocardial ischemia and clinical applications of positron emission tomography. Am J Cardiol 1989;64:46E-53E.

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Nicolai, E., Cuocolo, A., Pace, L. et al. Adenosine coronary vasodilation quantitative technetium 99m methoxy isobutyl isonitrile myocardial tomography in the identification and localization of coronary artery disease. J Nucl Cardiol 3, 9–17 (1996). https://doi.org/10.1016/S1071-3581(96)90019-7

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1016/S1071-3581(96)90019-7

Key Words

Navigation