Abstract
Purpose
Acetate templates were commonly used for templating for total hip arthroplasty. With digital radiographs having replaced conventional analogue radiographs, newer techniques are required. We describe a method for templating images of digital radiographs using conventional acetate templates, which is independent of a magnification marker or PACS system.
Methods
Fifty-one patients (64 hips) who were treated with primary THA were prospectively evaluated. Templating was done by keeping the acetate template directly over the digital image of the radiograph on a liquid crystal display (LCD) monitor, after calibrating the linear scale generated by the digital radiography machine. The size of prosthesis predicted on this templating technique was compared with the actual sizes used during the surgery. Inter-observer and intra-observer reliabilities were assessed. Our calibration method was further validated by comparing the size of the cup calculated on postoperative radiograph using digital templating software (mediCAD Hectec GmbH) and the actual size used during surgery.
Results
Accurate size was predicted for 36.7% of the acetabular cup and 35.9% of femoral stems. The accuracy within ± one size was 89.9% for acetabular cups and 91.4% for femoral stems. Excellent inter-observer and intra-observer reliability were seen for both femoral and acetabular components.
Conclusion
The method described provides an accurate, reproducible, convenient and low-cost technique of preoperative templating. It combines the ease of using acetate templates with the convenience of being able to use digital images, without the need for expensive software.
Similar content being viewed by others
References
Bourne, R. B., & Rorabeck, C. H. (2002). Soft tissue balancing: the hip. Journal of Arthroplasty, 17(4 Suppl 1), 17–22. https://doi.org/10.1054/arth.2002.33263
O’Sullivan, M., Tai, C. C., Richards, S., Skyrme, A. D., Walter, W. L., & Walter, W. K. (2007). Iliopsoas tendonitis a complication after total hip arthroplasty. Journal of Arthroplasty, 22(2), 166–170. https://doi.org/10.1016/j.arth.2006.05.034
McAuley, J. P., & Ridgeway, S. R. (2001). Preoperative planning to prevent dislocation of the hip. Orthopaedics Clinics North America, 32(4), 579–586. https://doi.org/10.1016/s0030-5898(05)70228-5
Crooijmans, H. J. A., Laumen, A. M. R. P., van Pul, C., & van Mourik, J. B. A. (2009). A new digital preoperative planning method for total hip arthroplasties. Clinical Orthopaedics, 467(4), 909–916. https://doi.org/10.1007/s11999-008-0486-y
Iorio, R., Siegel, J., Specht, L. M., Tilzey, J. F., Hartman, A., & Healy, W. L. (2009). A comparison of acetate vs digital templating for preoperative planning of total hip arthroplasty: is digital templating accurate and safe? Journal of Arthroplasty, 24(2), 175–179. https://doi.org/10.1016/j.arth.2007.11.019
Suh, K. T., Cheon, S. J., & Kim, D. W. (2004). Comparison of preoperative templating with postoperative assessment in cementless total hip arthroplasty. Acta Orthopaedica Scandinavica, 75(1), 40–44. https://doi.org/10.1080/00016470410001708070
Unnanuntana, A., Wagner, D., & Goodman, S. B. (2009). The accuracy of preoperative templating in cementless total hip arthroplasty. Journal of Arthroplasty, 24(2), 180–186. https://doi.org/10.1016/j.arth.2007.10.032
Sinclair, V. F., Wilson, J., Jain, N. P. M., & Knowles, D. (2014). Assessment of accuracy of marker ball placement in pre-operative templating for total hip arthroplasty. Journal of Arthroplasty, 29(8), 1658–1660. https://doi.org/10.1016/j.arth.2014.03.013
Bertz, A., Indrekvam, K., Ahmed, M., Englund, E., & Sayed-Noor, A. S. (2012). Validity and reliability of preoperative templating in total hip arthroplasty using a digital templating system. Skeletal Radiology, 41(10), 1245–1249. https://doi.org/10.1007/s00256-012-1431-4
Shin, J. K., Son, S. M., Kim, T. W., Shin, W. C., Lee, J. S., & Suh, K. T. (2016). Accuracy and reliability of preoperative on-screen templating using digital radiographs for total hip arthroplasty. Hip Pelvis, 28(4), 201–207. https://doi.org/10.5371/hp.2016.28.4.201
Brew, C. J., Simpson, P. M., Whitehouse, S. L., Donnelly, W., Crawford, R. W., & Hubble, M. J. W. (2012). Scaling digital radiographs for templating in total hip arthroplasty using conventional acetate templates independent of calibration markers. Journal of Arthroplasty, 27(4), 643–647. https://doi.org/10.1016/j.arth.2011.08.002
Oddy, M. J., Jones, M. J., Pendegrass, C. J., Pilling, J. R., & Wimhurst, J. A. (2006). Assessment of reproducibility and accuracy in templating hybrid total hip arthroplasty using digital radiographs. Journal of Bone and Joint Surgery. British Volume, 88(5), 581–585. https://doi.org/10.1302/0301-620X.88B5.17184
White, S. P., Bainbridge, J., & Smith, E. J. (2008). Assessment of magnification of digital pelvic radiographs in total hip arthroplasty using templating software. Annals of the Royal College of Surgeons of England, 90(7), 592–596. https://doi.org/10.1308/003588408X318101
Miashiro, E. H., Fujiki, E. N., Yamaguchi, E. N., Chikude, T., Rodrigues, L. H. S., Fontes, G. M., et al. (2014). Preoperative planning of primary total hip arthroplasty using conventional radiographs. Revista Brasileira de Ortopedia., 49(2), 140–148. https://doi.org/10.1016/j.rboe.2014.03.019
Kulkarni, A., Partington, P., Kelly, D., & Muller, S. (2008). Disc calibration for digital templating in hip replacement. Journal of Bone and Joint Surgery. British Volume, 90(12), 1623–1626. https://doi.org/10.1302/0301-620X.90B12.20238
Gamble, P., de Beer, J., Petruccelli, D., & Winemaker, M. (2010). The accuracy of digital templating in uncemented total hip arthroplasty. Journal of Arthroplasty, 25(4), 529–532. https://doi.org/10.1016/j.arth.2009.04.011
Wimsey, S., Pickard, R., & Shaw, G. (2006). Accurate scaling of digital radiographs of the pelvis. A prospective trial of two methods. Journal of Bone and Joint Surgery British Volume, 88(11), 1508–1512. https://doi.org/10.1302/0301-620X.88B11.18017
Franken, M., Grimm, B., & Heyligers, I. (2010). A comparison of four systems for calibration when templating for total hip replacement with digital radiography. Journal of Bone and Joint Surgery. British Volume, 92(1), 136–141. https://doi.org/10.1302/0301-620X.92B1.22257
Petretta, R., Strelzow, J., Ohly, N. E., Misur, P., & Masri, B. A. (2015). Acetate templating on digital images is more accurate than computer-based templating for total hip arthroplasty. Clinical Orthopaedics, 473(12), 3752–3759. https://doi.org/10.1007/s11999-015-4321-y
Krishnamoorthy, V. P., Perumal, R., Daniel, A. J., & Poonnoose, P. M. (2015). Accuracy of templating the acetabular cup size in Total Hip Replacement using conventional acetate templates on digital radiographs. Journal of Clinical Orthopaedics and Trauma, 6(4), 215–219. https://doi.org/10.1016/j.jcot.2015.04.001
Pullen, W. M., & Whiddon, D. R. (2013). Accuracy and reliability of digital templating in primary total hip arthroplasty. Journal of Surgical Orthopaedic Advances, 22(2), 148–151. https://doi.org/10.3113/jsoa.2013.0148
Shaarani, S. R., McHugh, G., & Collins, D. A. (2013). Accuracy of digital preoperative templating in 100 consecutive uncemented total hip arthroplasties: a single surgeon series. Journal of Arthroplasty, 28(2), 331–337. https://doi.org/10.1016/j.arth.2012.06.009 (Epub 2012 Jul 31).
Kumar, P. G. A., Kirmani, S. J., Humberg, H., Kavarthapu, V., & Li, P. (2009). Reproducibility and accuracy of templating uncemented THA with digital radiographic and digital TraumaCad templating software. Orthopedics, 32(11), 815. https://doi.org/10.3928/01477447-20090922-08
Jeyaseelan, L., Ward, J., Anand, A., Rhee, S., Eleftheriou, K., & Cobb, J. (2011). Digital templating in total hip arthroplasty in the NHS: ‘computer says no...’ European Journal of Orthopaedic Surgery & Traumatology, 21, 397–399. https://doi.org/10.1007/s00590-010-0735-0
Funding
There is no funding source.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Ethical standard statement
This article does not contain any studies with human participants or animals performed by any of the authors.
Informed consent
Informed consent was obtained from all individual participants included in the study.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Goyal, T., Sethy, S.S., Ansari, S. et al. Use of Acetate Templates Over Digital Radiographs for Templating in Total Hip Arthroplasty: Technique and Its Validation. JOIO 55 (Suppl 1), 81–87 (2021). https://doi.org/10.1007/s43465-020-00300-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s43465-020-00300-6