Hall sensor angle error and relative position calibrations for cryogenic permanent magnet undulator of high energy photon source test facility (HEPS-TF)

  • Review
  • Published:
Radiation Detection Technology and Methods Aims and scope Submit manuscript

A Correction to this article was published on 13 March 2018

This article has been updated

Abstract

Purpose

A new in-vacuum three-dimensional Hall probe magnetic measurement system is under fabrication for characterizing the magnetic performance of the Cryogenic Permanent Magnet Undulator (CPMU). In order to fit the small gap (5 mm) of magnetic structure and vacuum environment, a small three-dimensional Hall probe has been manufactured. The angular and positional misalignment errors of the Hall sensors play an important role in the measurement accuracy of the CPMU. In order to minimize the misalignment errors, a method of calibrating angle error and relative assembly displacements of a three-dimensional Hall probe is carried out.

Methods

The angle error of Hall sensors will be calibrated by a standard dipole magnet and a five-dimensional Hall bench. The standard dipole magnet will generate a single direction and uniform magnetic field. And the five-dimensional Hall bench is used to rotate the Hall probe which is put in the center of magnet. Based on the relationship between angle and magnetic field strength, the angle error of each Hall sensor will be obtained. The relative position between the sensitive areas of the Hall sensors will be calibrated by a two-dimensional magnetic field undulator section. Based on Maxwell’s equations, through the calculation of measurement magnetic field strength, the relative assembly displacements of the three Hall sensors can be derived.

Results

The details of the calibration methods and the data processing of angle error and relative assembly displacements of a three-dimensional Hall probe are presented. The three-dimensional magnetic fields of a cryogenic permanent magnet undulator can be received accurately by correcting these angle errors and position errors of Hall sensors.

Conclusions

This paper illustrates the relative position and angle calibration procedures and the data processing of a three-dimensional Hall probe. Now the design of a smaller Hall probe is in process. The calibration of the angle errors and position errors will be carried out after the fabrication of the standard dipole magnet.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

Change history

  • 13 March 2018

    The original version of these four articles as below unfortunately contained a mistake. The category “Review” was incorrect. The correct category is “Original Paper”.

References

  1. X. Jiang, J.Q. WANG, Q. QIN, Chinese high energy photon source and the test facility[J]. Sci. Sinica Phys. Mech. Astron. 44(10), 1075 (2014)

    Article  Google Scholar 

  2. W. Lei, W. Xiao-Long, L. Chun-Hua et al., Preliminary R&D of vibrating wire alignment technique for HEPS[J]. Chin. Phys. C 39(8), 087002 (2015)

    Article  ADS  Google Scholar 

  3. S. C. Sun and al., Mechanical design of a cryogenic permanent magnet undulator at IHEP. in Proceeding of the IPAC17, 8th International Particle Accelerator Conference, May 14–19, Copenhagen, Denmark, TUPAB066, (2017)

  4. L. Zhang and al., Design of the CPMU vacuum system at the HEPS. in Proceeding of the IPAC17, 8th International Particle Accelerator Conference, May 14–19, Copenhagen, Denmark, TUPAB068, (2017)

  5. Y. Yang, H. Lu, S. Sun et al., Field Error Correction Considerations of Cryogenic Permanent Magnet Undulator (CPMU) for High Energy Photon Source Test Facility (HEPS-TF)[C]. in 7th International Particle Accelerator Conference (IPAC’16), Busan, Korea, May 8–13, JACOW, Geneva, Switzerland, 4038–4040, (2016)

  6. H. H. Lu and al., Development of a PrFeB cryogenic permanent magnet undulator (CPMU) prototype At IHEP. in Proceeding of the IPAC17, 8th International Particle Accelerator Conference, May 14–19, Copenhagen, Denmark, TUPAB064, (2017)

  7. C. Kitegi, Development of a Cryogenic Permanent Magnet Undulator at the ESRF[D] (Université Joseph Fourier, Grenoble, 2009)

    Google Scholar 

  8. W. Chen, C T. Shi, H H. Lu, et al., Development of insertion devices measurement system at IHEP[J]

  9. http://www.akm.com/akm/en/file/datasheet/HG-116C.pdf

  10. J. Campmany, J. Marcos, V. Massana, New improvements in magnetic measurements laboratory of the ALBA synchrotron facility[J]. Phys.Proced. 75, 1214–1221 (2015)

    Article  ADS  Google Scholar 

  11. J. Marcos, J. Campmany, V. Massana, et al., Construction & commissioning of a 3D hall probe bench for insertion devices measurements at ALBA Synchrotron Light Source[C]. Contribution to the International Magnetic Measurements Workshop IMMW15. Fermi National Accelerator Lab. (2007)

  12. Z. Wolf, Hall element angle calibrations for the delta undulator LCLS-TN-13-10

  13. J. Chavanne, P. Elleaume, Technology of insertion devices[J]. Undulators Wigglers Appl. 1, 148–213 (2003)

    Article  Google Scholar 

  14. J. Campmany , J. Marcos , V. Massana , et al., Status of magnetic measurements at ALBA[C]. in International Magnetic Measurements Workshop IMMW18, (2013)

Download references

Acknowledgements

The authors would like to acknowledge Dr. Shu Guan, Dr. Wu Lei, Dr. Gu Kuixiang and Dr. Tang Zheng for great helpful discussion and suggestion.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ling-Ling Gong.

Additional information

A correction to this article is available online at https://doi.org/10.1007/s41605-018-0036-4.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Gong, LL., Chen, W., Kang, W. et al. Hall sensor angle error and relative position calibrations for cryogenic permanent magnet undulator of high energy photon source test facility (HEPS-TF). Radiat Detect Technol Methods 1, 17 (2017). https://doi.org/10.1007/s41605-017-0018-y

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s41605-017-0018-y

Keywords

PACS

Navigation