Introduction

Austenitic stainless steels provide a good combination of mechanical properties and corrosion resistance, and are therefore widely used in, for example, transportation, oil and gas, medical and electrical engineering applications. In metastable alloys the strain-induced martensitic phase transformation produces higher ductility and strength. From the early works of Olson and Cohen [1, 2], a great deal of effort has gone into studying the mechanisms and parameters affecting the strain-induced phase transformation. It is widely known that the phase transformation rate is reduced as the temperature increases [3, 4]. The phase transformation rate is also reduced when the deformation occurs at high strain rates [5]. At high strain rates, the temperature increases due to adiabatic heating. The dominant theory is that, at high strain rates, the temperature rise due to adiabatic heating increases the stacking fault energy, suppressing the martensitic phase transformation [6,7,8,9,10,11]. Other researchers [12,13,14,15] suggest that also the strain rate itself, and not only the adiabatic heating, has a direct effect on the martensitic phase transformation.

It is evident that more work is needed to quantitatively separate the effects of temperature and strain rate on the martensitic phase transformation. On this line, Isakov et al. [16] performed tensile strain rate jump tests on a AISI 301 steel. In these tests, the strain rate was suddenly increased by several orders of magnitude, from quasi-static to dynamic conditions. The authors observed that the strain hardening rate of the steel decreased instantaneously after the sudden increase of strain rate. A previous study of the current authors showed that the specimen deformed uniformly after the sudden increase of strain rate until necking started [17]. However previous investigations have not been able to provide adequate evidence on what happens to the temperature of the specimen during a rapid change of strain rate. This report provides convincing experimental data which shows that the thermomechanical behavior and especially the adiabatic heating of the two studied austenitic steels is predictable during a sudden increase of strain rate. The results show that the temperature of both steels increases moderately after the strain rate jump, and no unexpected behavior is observed. This indicates clearly that the strain rate jump test can be used for the evaluation of the material behavior. The results show that the instantaneous drop in the strain hardening rate observed in the metastable austenitic steel is not caused by sudden increase in the bulk temperature of the specimen.

Materials and Experimental Methodology

Two standard stainless steel AISI 301 LN (EN 1.4318) and AISI 316 (EN 1.4420) were studied in the 2B cold rolling condition. Tension specimens with a gage length of 8 mm, and a shoulder radius of 2 mm and a width of 4 mm were laser cut from 2 mm sheets provided by Outokumpu Stainless LTD. The rolling direction was parallel to the loading direction. The specimens were tested in tension at a strain rate of ~ 2 × 10–4 s−1 until reaching a predetermined deformation where the strain rate was suddenly increased up to 1.3 × 103 s−1 by impacting the striker bar driven by compressed air to the flange at the free end of the incident bar. These strain rate jump tests were performed using a modified Tensile Split Hopkinson Bar (TSHB). Figure 1 shows a schematic picture of the test setup. For further details see ref. [18].

Fig. 1
figure 1

Schematic picture of the modified Tensile Split Hopkinson Bar, adapted from [17]

Full field strain and temperature measurements were carried out using Digital Image Correlation (DIC) and Infrared Thermography (IRT). The low rate loading of the test was recorded using two 5 MPix E-lite cameras with 200 mm lenses at a frame rate of 2 Hz, whereas the high rate loading was recorded using a Photron SA-X2 high speed camera with 100 mm lens at a frame rate of 90 kHz with a resolution of 640 × 152 pixels. A Telops Fast-IR-M2K infrared camera was imaging the opposite side of the specimen synchronously with the high speed optical camera at 90 kHz with a resolution of 64 × 4 pixels. Figure 2 shows the setup used for the full field measurements during the strain rate jump tests.

Fig. 2
figure 2

Experimental setup for the full field strain and temperature measurement during the strain rate jump tests [15]

The strains were obtained with Davis10 (LaVision GmbH) software. A high contrast speckle pattern was applied on the specimen surface with a 0.4 mm tip marker. Before starting each test, the unloaded specimen was imaged with both the low and the high-speed DIC systems. These images were used as the reference image to calculate the strain. The engineering strain on the specimen was calculated by placing a virtual extensometer of 6 mm length on the same location in both low and high-speed images. A more detailed description of the digital image processing of the images and the use of the virtual extensometer is given in ref. [15].

The thermal data requires a calibration to convert radiometric temperature into true surface temperature. The temperature calibration was performed by heating a specimen slowly while measuring its temperature with the camera and a thermocouple that was spot welded to the surface of the specimen. The details of the calibration can be found in ref. [15].

Results

Figure 3 presents the true stress – true strain and strain hardening rate curves for the studied materials. The strain hardening rate \(\left( {\frac{{\partial \sigma }}{{\partial \varepsilon }}} \right)\) was calculated from the stress strain curve. Figure 3a and b show the data from tests carried out without the strain rate jump at strain rates of 2 × 10–4 s−1 and 1.3 × 103 s−1. For the stable 316 steel, increasing the strain rate increases the flow stress without affecting the strain hardening rate of the material. For the metastable 301 steel, however, the stress–strain curve at the lower strain rate has an S-shape due to the strain-induced phase transformation. At 2 × 10–4 s−1, the 301 steel strain hardens notably with the accumulation of plastic strain. At the strain rate of 1.3 × 103 s−1, the stress–strain curve no longer has the S-shape and the strain hardening rate of the material does not increase with further deformation. Figure 3c–h show the results of the jump tests where the increase of strain rate occurs after a pre-strain of 0.10 (c-d), 0.20 (e–f), and around 0.30 (g-h). For the stable 316 steel, the strain hardening rate seems to be unaffected by the strain rate jump at any studied pre-strain. For the metastable 301, the sudden increase of strain rate at a pre-strain of 0.10 seems to have very little effect on the strain hardening rate, but when the sudden increase of strain rate takes place at 0.20 and 0.30 of pre-strain, however, the strain hardening rate drops significantly after jump.

Fig. 3
figure 3

True stress—true strain curves and strain hardening rates of the stable 316 steel (on the left) and the metastable 301 steel (on the right) at the constant strain rates of 2 × 10–4 s−1 and 1.3 × 103 s−1 (a, b), and strain rate jumps at the true strain of, approximately, 0.10 (c, d), 0.20 (e, f), and 0.30 (g, h)

Figure 4 shows the measured temperature increase as a function of true strain during the high rate loading part of the tests. It can be observed that the slope of the temperature increase becomes steeper as the amount of plastic prestrain increases. This can be explained by the increased flow stress after the jump, which increases the amount of mechanical work put into the specimen for further deformation. The temperature increase measured after certain amount of deformation is lower for the stable 316 steel (Fig. 4a) than that measured for the metastable 301 steel (Fig. 4b). However, for all the tests, both with and without strain rate jump, the temperature increases gradually once the high rate loading starts. After the first 0.05 mm/mm of true strain, the highest measured temperature increase is 12 K. The resolution, accuracy and uncertainties related to the measurements are discussed in detail in ref. [19].

Fig. 4
figure 4

Temperature increase as a function of true strain during high rate loading of the tests for a the stable 316 steel and b the metastable 301 steel. The specimen was at room temperature (298 K) at the beginning of the test

Discussion

A clear decrease in the strain hardening rate can be observed in the strain rate jump experiments of the metastable stainless steel, which indicates that the rate at which the microstructure evolves changes dramatically when the strain rate is increased. This is caused by the changes in the phase transformation rate which decreases significantly at high strain rate [14]. However, the immediate decrease in the strain hardening rate cannot be explained by macroscopic heating of the specimen, as the bulk temperature does not increase suddenly during the strain rate jump. Instead, a gradual temperature increase is observed. Therefore, this finding suggests that either the strain rate itself affects the dynamics of the strain induced martensite transformation and/or that the adiabatic heating may be heterogeneous and some local ‘hot spots’ are formed in the microstructure. These locally heated areas then may affect the transformation behavior more strongly than what the global or average heating suggests. Further investigations on the local microstructure level deformation and adiabatic heating are needed.

Conclusions

This study led to the following conclusions:

  • The bulk heating of the specimen does not suddenly increase during or after a large upward strain rate jump, instead the temperature rises gradually, as is expected based on the conversion of plastic deformation work into heat.

  • The results indicate that the global adiabatic heating is not responsible for the sudden change in the strain hardening and phase transformation rates that is observed in a strain rate jump test of metastable austenitic steels.

The processed data is available through ref. [20].