1 Introduction

In order to fulfill the current demands for reducing CO2 emissions, energy-efficient vehicles must be realized through approaches such as lightweight construction. By using electrically conductive materials with a lower density compared to the most commonly used material, copper, weight can be reduced. One approach is the substitution of copper by aluminum. Aluminum has a density which is about 70% lower than copper [1]. Since the conductivity of aluminum is lower than that of copper, the cross section of aluminum conductors must be increased by approximately 60%. Despite the increase in the conductor cross section, it is possible to achieve a theoretical weight saving up to 50% [2]. Due to the properties of aluminum, such as the creep behavior and its oxide layer, the substitution can only be partial. The contacts provided for consumers and energy suppliers remain made of copper. Therefore, there is a need for the production of mixed aluminum/copper compounds. Due to the properties of the two materials (different melting temperatures, different coefficients of thermal expansion, and different thermal conductivities, as well as the tendency to form brittle, intermetallic compounds with high specific electrical resistance), the manufacturing of these mixed joints is a challenge for joining technologies [1]; [3]; [4]; [5]. The use of friction-based solid-state welding processes such as friction stir welding (FSW) [6]; [7]; [8]; [9]; [10]; [11]; [12]; [13] or ultrasonic welding (USW) [14]; [15]; [16]; [17]; [18]; [19]; [20] can produce dissimilar material connections in several material combinations including Al and Cu. The formation of brittle intermetallic phases such as AlCu and Al4Cu9 can be reduced when using ultrasonic welding by keeping the joining zone temperatures below the liquidus temperature of the joining partners [14]; [21]. During the lifetime of a vehicle, the ultrasonic welded joints are exposed to various environmental influences. Therefore, such joints are protected against the harmful environmental influences in these industrial applications. This is achieved either by specific insulation of the joint by using protective plastic sealing or by the use of suitable coating of the copper elements. Nickel coatings, which act as a diffusion barrier between aluminum and copper, are frequently used for this purpose and can thus reduce corrosion [2]; [22]; [23]; [24]; [25]. These coatings can be distinguished by the type of nickel coating process, the composition of the electrolytes, the composition of the coating and the mechanical, chemical, and tribological properties. In this work, selected nickel types that are used in the industry (electroplated nickel, electroless nickel, and sulfamate nickel) are examined with regard to their suitability for maintaining the long-term stability of the compound.

The state of the art shows different investigations regarding ultrasonic welded aluminum/copper joints with coated joining partners as well as ultrasonic welding of aluminum and nickel. Ni et al. investigated the weldability and the mechanical properties of ultrasonic welded aluminum/nickel joints [26]. In their work, an improvement in tensile shear load by adding Al2219 particles between the interface of the aluminum and nickel sheets could be outlined [26]. Balasundaram et al. showed that Al-Cu joints with a Zn interlayer in the interface can be characterized by a tensile shear load of 25–170% higher than samples without a Zn interlayer [27]. Regarding the aging of Al/Cu joints without coating, Oberst et al. analyzed the aging mechanisms for bolted aluminum and copper busbar joints [28]. They showed that a higher temperature load leads to a faster deterioration of the connection and that the formed intermetallic compounds did not have a significant influence on the contact resistance [28]. Furthermore, Oberst et al. investigated the influence of different temperature loads on the building rates of IMCs for Al/Cu joints, Al/Ni/Cu joints as well as other material combinations in order to determine a maximum temperature at which the connections can be used [29]. Bergmann et al. studied the influence of thermal load tests on ultrasonic welded aluminum wire-copper terminal connections considering different nickel coatings [2]. In their research, the welded samples were exposed to a thermal load of 350 °C for 45 h. The authors showed a reduced failure load of up to 43% for nickel-plated samples and a reduced failure load of 60% for Al/Cu joints without coating [2].

The analysis of the state of the art shows that the use of coatings for dissimilar Al/Cu joints can have a positive influence on the mechanical properties and on the long-term stability. Hence, the objective of this work is to analyze the influence of various nickel types on the long-term behavior of the ultrasonic welded mixed cable-conductor connections. Those were investigated under thermal, corrosive, electrical, and vibration loads using conditions that will occur in the life cycle in an automotive environment. Therefore, test methods and standards from the automotive industry were used to test the samples according to the requirements of a life cycle.

2 Experimental procedure

The experiments were carried out on a linear ultrasonic welding machine that could realize a maximum power of 6.5 kW and a maximum welding force of 4 kN. The horn used has a square surface with an edge length of 16 mm and a corrugated profile. In this study, a time-controlled welding process was selected and performed with the welding parameters listed in Table 1. For the experimental procedure, EN AW 1370 cables with a cross section of 60 mm2 were used; these had PVC insulation and were stripped 20 mm at each end of the cable. The total cable length was 300 mm. The copper terminals used had a thickness of 3 mm, a width of 22.5 mm, and a length of 50 mm. The sample arrangement of the cable-conductor connection for the welding experiment is shown in Fig. 1a and b.

Table 1 Process variables
Fig. 1
figure 1

Experimental setup

Typical materials for battery technology and the automotive industry were used for welding the stranded wire-arrester connection. For example, a soft-annealed pure aluminum (EN AW 1370) was used as strand material and a copper sheet (EN CW 004A) as arrester, both with high corrosion resistance and electrical conductivity. The chemical compositions are shown in Table 2 and Table 3.

Table 2 Chemical composition EN CW 004A in wt% [30]
Table 3 Chemical composition EN AW 1370 in wt% [31]

An electroless nickel with high phosphorus content, an additive-free electroplated nickel coating, and an electroplated sulfamate nickel (see Table 4) were selected for the coating of the copper terminals. The layer thickness for all coatings was set to 5 μm ± 1 μm, since a closed layer can be guaranteed from this layer thickness taking into account the variations. The samples were analyzed with an XRAY XDV-SDD device. The measurements were performed on three coated copper terminals with 24 measuring points per coating type. Figure 2 shows the layer thickness as a function of the type of coating. It can be seen that the measured layer thicknesses are above 5 μm due to process variations. The variation of the layer thickness of electroplated and electroless nickel-plated samples is high in comparison to sulfamate nickel-plated samples.

Table 4 Nickel coating types
Fig. 2
figure 2

Measured Ni layer thickness in dependence of the nickel types

The objective of this paper is to investigate the influence of different long-term tests on the joint quality of ultrasonic welded samples. The samples were subjected to electrical, corrosive, thermal, and vibration loads. In the context of the long-term tests on thermal load, the samples were thermally stored in an oven. Due to the requirements in an automotive vehicle, temperatures of 140 °C and 180 °C were chosen and the samples were subjected to thermal testing for 500 h, 750 h, and 1000 h. The long-term behavior under current load was carried out in accordance with the UL 310 standard (see Fig. 3) [32]. Since this standard only specifies the test current for cables up to a maximum of 5.3 mm2, the current was adjusted according to the standard so that a node temperature of approx. 130 °C was reached. Thus, the test current determined amounted to 330 A. The test consisted of 500 cycles, whereby one cycle consisted of 45 min with current load and 15 min without current load. The voltage for the resistance measurement was tapped at a distance of approximately 2 mm from the end of the cable. Furthermore, the temperature of the weld nodes was measured via thermocouples.

Fig. 3
figure 3

Experimental setup of the electrical load tests (© Stocko Contact AG)

In order to test the influence of a vibration load on the long-term behavior of the ultrasonic welded stranded wire-conductor connections, a vibration test according to VW standard 80000 M-04 [33] was carried out (see Fig. 4). The vibration profile D was selected for components mounted on suspended masses in the car chassis. Each dimensional direction was tested over a period of 8 h. The long-term behavior under corrosive load was carried out according to DIN EN ISO 11130 [34]. In accordance with this standard, the samples were stored in a salt water solution. The salt solution was a mixture of H2O and NaCl, of which 35 g ± 1 g/l salt was dissolved in water. The samples were tested after 250, 500, 750, and 1000 cycles. In accordance with the standard, one cycle consisted of 10 min in the salt water solution and 50 min drying phase. Before each measurement, the samples were cleaned with clear water and stored for 24 h to dry.

Fig. 4
figure 4

Experimental setup of the vibration tests (© TechnoLab GmbH)

After the long-term tests, the samples were tested by electrical, mechanical, and metallographic means. The measurements of the electrical resistance of the connections were performed based on the principle of the four-point measurement method (see Fig. 5). The measured values result from the sum of the electrical resistances of the cable and two welded connections. The welded specimens were mechanically tested on a tensile testing machine with a maximum test load of 20 kN, a test speed of 10 mm/min, and a set force drop of 95%. The free clamping length of the cables was set to 60 mm.

Fig. 5
figure 5

Experimental setup for measuring the electrical resistance

3 Results

In this work, the focus is on the influence of the coating types on the long-term behavior of the welded joints. For this purpose, the samples were exposed to thermal, corrosive, and electrical loads and vibration tests.

3.1 Corrosion test

Depending on the application site, the material connection may come into contact with liquid. To simulate this corrosive load, a corrosive test in salt water according to ISO 11130 was performed. Specimens that were welded with the parameters t = 1000 ms, F = 1.7 kN, and A = 33.5 μm were tested for up to 1500 h. Figure 6 shows the analysis of the influence of different types of coating on the electrical resistance as a function of the aging time. The specimens were electrically tested after 250 h, 500 h, 750 h, 1000 h, and 1500 h aging time. In addition, the samples were mechanically tested after 1000 cycles. The measured value represents the electrical resistance of a cable connection with two welded Al-Cu connections. All coating types investigated can be described by an increase of the mean value and by the variation of the electrical resistance depending on the duration of the load. The largest increase in resistance from R = 142.5 ± 1.9 μΩ (as welded) to R = 158.7 ± 4.9 μΩ (1500 cycles) is observed on uncoated samples.

Fig. 6
figure 6

Influence of the duration of the corrosion test and the type of coating on the electrical resistance of the welded samples (t = 1000 ms; F = 1.7 kN; A = 33.5 μm)

The data shown in the diagram indicate that all coated samples display an increase in electrical resistance. Taking electroplated samples as an example, it can be seen that the resistance here increases from R = 141.4 ± 1.1 μΩ (as welded) to R = 149.0 ± 3.7 μΩ (after 1500 cycles).

In the next step, the influence of the coating type on the shear tensile load and peel tensile load was investigated. For this purpose, samples loaded for 1000 cycles were mechanically tested. The results of this investigation are shown in Fig. 7. Both test methods showed that the type of coating has no significant influence on the failure loads of corrosively exposed cable-arrester connections. The failure load of the samples after a peel tensile test is in the range of approx. 500 N, irrespective of the type of coating. The failure loads here are characterized by a comparatively low variation. The results of the shear tensile test show that uncoated samples have a higher average failure load than electroplated and electroless nickel-plated samples. The tendency of uncoated specimens to be more susceptible to corrosion, which was determined during the examination of the electrical resistance, was not confirmed by the mechanical test. This can be explained by the fact that the corrosion takes place in the strand node and not in the joining zone. Thus, a corrosion test according to the parameters described above has an influence on the electrical resistance, but not on the failure load of the samples.

Fig. 7
figure 7

Influence of the corrosion test and the type of coating on the tensile shear force and the tensile peel force (t = 1000 ms; F = 1.7 kN; A = 33.5 μm, aging time = 1000 h)

3.2 Electrical load test

In the next step, the influence of the long-term behavior under current load and the type of coating on the failure load and the electrical resistance were investigated. The current load tests were carried out according to the automotive standard UL 310. The tests were performed with specimens that were welded with a welding time of t = 1000 ms, an amplitude of A = 33.5 μm, and the welding forces F = 1.7 kN and F = 2.0 kN. Figure 8 shows the electrical resistance as a function of the type of coating and the welding force. The electrical resistance was measured for all samples before and after the 500 load cycles. The diagram also shows the node temperature during the electrical load test as a function of the abovementioned parameters. The temperature is shown for samples after one cycle (as welded) and after 500 cycles.

Fig. 8
figure 8

Influence of the electrical load test and the welding force on the electrical resistance and the node temperature (t = 1000 ms; F = 1.7 kN and 2.0 kN; A = 33.5 μm)

The results in Fig. 8 illustrate that the electrical resistance and the node temperature for uncoated samples increase slightly after the load test for samples joined with a welding force of F = 1.7 kN. In contrast, the influence of a welding force increased to F = 2.0 kN leads to a comparatively stronger increase in electrical resistance and node temperature. For example, the electrical resistance of electroplated nickel samples increases from R = 168.7 ± 4.5 μΩ (as welded) to F = 181.0 ± 7.8 μΩ (after 500 cycles) and the mean node temperature from T = 138.6 ± 1.0 °C (as welded) to T = 143.8 ± 1.0 °C (after 500 cycles). Thus, a significant influence of the welding parameters on the measured values can be recognized. This behavior can be seen for uncoated and for all coated samples that were examined. The increase of the node temperature can be attributed to the increase of the electrical resistance. The temperature load during the test can cause intermetallic phases with a higher specific electrical resistance to be formed, so that the node temperature increases as a result. A higher node temperature in return can lead to an increasing growth of intermetallic phases. The growing diffusion layer can be observed under the light microscope on uncoated samples (see Fig. 9 a). The increase in electrical resistance and the associated increase in node temperature also affect the mechanical properties of the samples due to the growth of intermetallic phases. The growth of a diffusion layer between Al and Ni could not be detected with a light microscope.

Fig. 9
figure 9

Metallographic analysis of the interface between aluminum and copper or nickel (t = 1000 ms; F = 1.7 kN; 2.0 kN; A = 33.5 μm; magnification = × 1000). a Uncoated copper terminal. b Electroplated nickel-coated copper terminal. c Electroless nickel-plated copper terminal. d Sulfamate nickel-plated copper terminal

Figure 10 shows the failure load of the electrically tested and untested samples. It can be seen that a slight increase in the electrical resistance (see Fig. 8), with the selected load cycles, does not lead to any significant changes in the failure load of loaded samples compared to unloaded samples. This is the case with specimens welded with a welding force of F = 1.7 kN. In comparison, the specimens which were joined with a welding load of F = 2.0 kN show a reduction of failure load for uncoated and electroplated nickel-coated samples after the current load. For example, the mean failure load for uncoated samples is reduced from F = 3365.0 ± 115.0 N (as welded) to F = 3040.6 ± 211.3 N (after 500 cycles). For electroless nickel-plated specimens and for sulfamate nickel-plated specimens, the failure load remains constant after the load test. In summary, it can be stated that no significant changes in the failure load due to the electrical load test were observed for any coating type tested. All changes in the failure load are above the minimum acceptable failure load according to SAE guideline USCAR 38 [35]. A similar behavior can be seen in the failure mode of the samples after the tensile test. Figure 11 shows the failure behavior before and after the electrical load test for all tested coating types for a welding time of 1000 ms and a welding force of 1.7 kN. The samples showed a similar partial failure behavior in the aluminum base material and in the interface between aluminum and copper or nickel before and after the electric load tests.

Fig. 10
figure 10

Influence of the electrical load test and the welding force on the failure load (t = 1000 ms; F = 1.7 kN and 2.0 kN; A = 33.5 μm)

Fig. 11
figure 11

Failure behavior before and after 500 electric load cycles on welded cable-conductor connections; t = 1000 s; F = 1.7 kN; A = 33.5 μm

3.3 Vibration test

In the vehicle, the aluminum cables were exposed to different types of loads. Vibrations caused by driving and the engine can cause connections to fail. To test the influence of the coating type on the connection quality, the ultrasonic welded cable-arrester connections were exposed to a vibration test according to VW standard 80000 M-04.

Figure 12 shows the failure load before and after the vibration test as a function of welding time, welding force, and type of coating. Uncoated copper terminals (see Fig. 12 a), electroplated nickel-coated copper terminals (see Fig. 12 b), electroless nickel-coated copper terminals (see Fig. 12 c), and sulfamate nickel-coated terminals (see Fig. 12 d) were examined. Comparing the failure loads before and after the vibration test of uncoated samples, it can be seen that no significant differences were found for almost all process variables investigated. Only samples that were joined with a welding force of F = 1.7 kN and a welding time of t = 1200 ms show a higher average failure load after the vibration test. Since the vibration test has no positive effect on the mechanical properties, this effect can be explained by the general process uncertainties of the ultrasonic welding process. When looking at the samples coated with nickel, no influence of the type of coating can be detected. The failure load of both coated and uncoated samples is not adversely affected by the vibration test. This result can also be seen when considering the failure behavior of the samples before and after the vibration test (see Fig. 13). In Fig. 13, the failure behavior of electroless nickel-coated samples is considered as an example. The failure of the other coating types can be characterized by a similar behavior. A partial failure behavior in the interface and in the aluminum base material (welding node) can be determined. Hence, it can be proven that the samples are not significantly affected by the vibration test according to VW standard 80000 M-04, independent of the type of Ni coating. Despite the general process uncertainties, it was shown that the requirements for the failure load according to SAE guideline USCAR-38 (failure load ≥ 1800 N) [35] were fulfilled for all tested samples before and after the vibration test.

Fig. 12
figure 12

Influence of the vibration test according to VW standard 80000 M-04 (8 h/room axis with ae = 30.8 m/s2) on the failure load of welded cable/conductor connections (t = 800 s; 1000 s; 1200 s; F = 1.7 kN; 2.0 kN; A = 33.5 μm). a Uncoated samples. b Electroplated nickel-coated samples. c Electroless nickel-coated samples. d Sulfamate nickel-coated samples

Fig. 13
figure 13

Failure behavior before and after vibration test according to VW standard 80000 M-04 (8 h/room axis with ae = 30.8 m/s2) on welded cable-conductor connections; t = 1000 s; F = 1.7 kN; A = 33.5 μm; electroless nickel-coated samples

3.4 Thermal load test

The thermal emissions in the vehicle and the heating of the connections due to the electrical resistance lead to thermal stress on the vehicle electrical system. The welded cable-arrester connections were therefore exposed to thermal loads and then tested mechanically, metallographically, and electrically. The samples were stored at temperatures of 140 °C and 180 °C for 500 h, 750 h, and 1000 h. The samples tested were welded with a welding time of t = 1000 ms, a welding force of F = 1.7 kN, and an amplitude of A = 33.5 μm. Figure 14 shows the failure load as a function of the aging temperature, the aging time, and the type of coating. In the case of uncoated specimens, it can be seen that there is a tendency towards a reduction of the failure loads with increasing aging time. However, due to the standard deviation of the values, no definitive conclusion can be drawn on this basis. Also, an influence of the aging temperature on the failure load cannot be detected due to the standard deviation. When considering the electroplated samples, it can be shown that a tendency towards higher failure loads is manifested with a thermal aging of 180 °C.

Fig. 14
figure 14

Failure load as a function of the type of coating, the aging temperature, and the aging; t = 1000 ms; F = 1.7 kN; A = 33.5 μm

The reduction of the failure loads with uncoated samples and the almost constant failure loads with coated samples can be explained by reference to the detailed images of the joining zone in Fig. 15. In the case of uncoated samples, the phases Al4Cu9 and AlCu were formed in the interface of the joining zone in the samples shown, which were aged for 1000 h at 180 °C (see Fig. 15 a and Fig. 15 f). Due to the layer thickness of less than 2.5 μm, the phase seam has no negative effect on the mechanical properties of the compound [36]. The failure behavior of all aging temperatures and coating types in these tests can be described as a partial failure in the interface and in the aluminum base material similar to Fig. 11 and Fig. 13.

Fig. 15
figure 15

Cross-sectional images of thermally aged samples (180 °C, 1000 h) (t = 1000 ms; F = 1.7 kN; A = 33.5 μm). a Panoramic image of blank copper terminal. be Light microscopic images (× 1000 magnification). fi SEM images (× 11,000 magnification). b and f None coated copper terminal. c and g Electroplated nickel-coated copper terminal. d and h Electroless nickel-plated copper terminal. e and i Sulfamate nickel-plated copper terminal

In addition to the mechanical and metallographic analysis of the samples, they were also tested by means of electrical resistance measurement. The results of this examination are shown in Fig. 16. In this figure, the electrical resistance is shown as a function of the aging time and the type of coating at a constant aging temperature of 180 °C. It can be seen that there are no significant changes in the electrical resistance over the aging period. Differences can be explained by the measuring inaccuracy of the measuring system and the comparatively high deviations. The electrical resistance of an uncoated sample after an aging period of 1000 h can be determined to R = 146.6 ± 1.8 μΩ. The average resistance of electroplated nickel samples after 1000 h is R = 142.9 ± 0.4 μΩ. In summary, it can be shown that no significant differences could be found under the aging conditions investigated and that there is no difference in whether a coating is used or which type of coating is used.

Fig. 16
figure 16

Electrical resistance as a function of segregation duration at constant aging temperature (180 °C); t = 1000 ms; F = 1.7 kN; A = 33.5 μm

4 Conclusion

In this paper, the influence of different nickel coatings on the long-term stability of ultrasonic welded Al/Cu compounds was investigated. The long-term stability of the joints was tested according to current automotive industry standards based on thermal, corrosive, electrical, and vibration loads. As a result of the thermal load tests, it could be proven that no significant effects were found under the aging conditions investigated. In addition, no advantage of any particular type of coating could be identified. An electrical load test was also carried out. Here, an increase in electrical resistance and a reduction in the average failure load were detected after 500 load cycles for all coating types examined. In this case, the welding parameters (welding force and welding time) had a significant influence on the change in electrical resistance and the resulting failure load after the load test. Nevertheless, the changes in failure load are within the permissible range specified in the automotive standards UL310 and USCAR-38. The results of the corrosive immersion test can be summarized in such a way that the properties of the nickel layers as corrosion protection are given compared to uncoated samples. However, the difference in the change in electrical resistance between the uncoated and coated samples within the load cycles investigated can be neglected, since the coated samples are also negatively affected by the corrosive test. Finally, the long-term stability under a vibration load was investigated. After conducting the experiments according to VW Standard 80000 M-04, it was found that this test does not negatively affect the mechanical properties of the welded joints. In summary, it was shown that the influence of the coating types investigated in this study on the long-term stability of the joints was not significant. This means that both nickel-coated and uncoated copper terminals can be used for cable-conductor connections. Hence, consideration should be given to using uncoated samples in an industrial environment in order to reduce the production time and the production costs.