Introduction

It has been generally stated that climate change through global warming is one of the most serious environmental threats that humankind is facing; therefore, greenhouse gas emissions (GHG’s) should be reduced in every field of activities. During the last two decades, there was a growing scientific consensus that the rising atmospheric levels of CO2 as a result of man-made activities (e.g., fossil fuel burning, cement and lime production, ammonia and ethylene oxide synthesis, aluminum and glass industries, fermentation, deforestation, use of fertilizers, etc.) are responsible for around two-thirds of the greenhouse effects, while CO2 was recognized as the most significant anthropogenic greenhouse gas. For this reason, there is a pressing need to find ways for reducing CO2 levels in the atmosphere. The three possible ways towards this direction are: (1) increase of energy efficiency, (2) change of the fossil fuels to non-carbon forms of energy (e.g., renewable and nuclear energy) and (3) create CO2 sinks with the help of carbon capture and storage (CCS) technologies. Among these CCS is visualized as a promising strategy for mitigating CO2 emissions at short- and mid-term scenarios. In many industry sectors, CCS is the only technology that allows deep reductions in CO2 emissions. However, CCS in industrial applications has so far received little attention. Moreover, most studies on the potential application of CCS have focused on the power sector even though to achieve its full potential to reduce overall emissions, many other industry sectors must be considered [14].

Among the three steps of the CCS chain, CO2 capture is by far the most expensive one, accounting for 50–90 % of the overall chain cost depending on the CO2 emission source. Chemical absorption with alkanolamines (or variants) is today the benchmark technology for CO2 capture from flue gas streams. This technology enables the sorbed CO2 in the form of stable carbamate and/or bicarbonate species to be further sequestrated in a separate vessel by raising the temperature and/or lowering the pressure, so that the regenerated solvent is recycled in the absorption unit. However, despite the maturity of this process, it still remains energy intensive and costly and it requires the installation of voluminous units [5].

Gas separation membranes are a potential alternative to the conventional CO2 capture methods. Many commercial membrane technologies are available and already been applied to natural gas sweetening, where the concentrations of CO2 and H2S contained in high-pressure natural gas should be lowered to the levels of meeting the gas pipeline specifications. However, this does not necessarily ensure the feasibility of these membranes to flue gas treatment, because of several key differences between the two processes. Many different types of membranes have been considered for post-combustion CO2 capture, including glassy polymer membranes, facilitated transport membranes, mixed-matrix membranes and gas–liquid membrane contactors. These membranes have been extensively studied in lab or pilot scale, but no industrial application in flue gas treatment has been reported up to now [6].

Among the different available membrane technology methods, gas–liquid contact membranes seem to have the highest potential for large-scale applications, since they combine the advantages of gas separation polymeric membranes with that of absorption processes, creating a new way of contacting liquid and gases. In this respect, membrane gas absorption is a novel method with the advantages of higher efficiency, less required energy and lower costs in a more compact unit compared to the conventional absorption processes. Several extended reviews on gas–liquid contact membranes have been presented in the literature [79], where more details on the method and the potential applications can be found. CO2 capture from flue gases was among the first processes that attracted the scientific interest as a potential field of application and it is the currently most investigated target of membrane contactors. This application, initiated by Kvaerner Company in the late 1980s, clearly aims to use membrane contactors in a harsh environment which is very different from the clean, water-based applications developed up to now in the food and pharmaceutical sectors. The susceptibility of membrane material to wetting and membrane stability in chemically aggressive industrial environments are considered as the major hurdles for large-scale commercial applications [10].

In previous publications, our group studied both experimentally and theoretically CO2 capture from simulated flue gases using a membrane contactor, as well as the effect of membrane wetting in CO2 mass transfer resistance [1113]. The results indicated that CO2 capture with a membrane contacting process had very high potential for commercial application but the tests have to move from laboratory to a real industrial environment for a proof of concept validation in power generation as well as in other industry sectors. To the best of our knowledge, there are very few experiments conducted in real industrial environments, published in the open literature. Probably, the most prominent exception is the work conducted from the TNO group, who installed a membrane gas absorption pilot unit and studied CO2 capture from real flue gases, coming from a gas fired pilot plant [14].

The main goal of this study was the performance assessment of CO2 capture in a membrane gas absorption pilot unit installed in a Greek brick production industry (V. Maliouris S.A.). In the brick production process, large quantities of CO2 are released to the atmosphere during bricks calcination. In this step, the bricks enter the process furnace where they are heated up to ~950 °C using crude oil as a fuel. Crude oil combustion except of CO2 also results to the formation of SO2, NO x and other trace elements which further increase the loading of gas pollutants in the atmosphere. The company, except of the environmental considerations, has also profits from CO2 emissions reduction, as it is placed in the Emissions Trading System (ETS) for CO2 emissions monitoring. The special feature of this process is that the system is far from steady state, mainly because of furnace doors opening when wagons with bricks enter and exit the furnace. This causes significant dilution of flue gases and variability with time. All the above render the effective application of a membrane gas absorption unit for CO2 capture, to be a very challenging task, which has not been studied extensively up to now.

Experimental

A sketch of the bricks calcination process of Maliouris S.A. is shown in Fig. 1. The flue gases move reversely to the bricks direction and exit from the flue of the kiln.

Fig. 1
figure 1

Sketch of the bricks calcination process

The main pollutants in the flue gases were determined before the installation of the membrane contactor pilot unit, using the following standard analysis methods:

  • Humidity according to EN 14790:2005

  • Particulate matter according to EN 13284:2001

  • HCl according to EN 1911:2010

  • VOC according to EN 13649:2002

  • Smoke point according to ELOT 525.1

  • The gases O2, CO, NO, NO2 & SO2 were determined with a portable gas analyzer with an electrochemical sensor and the CO2 with a portable gas analyzer with an NDIR sensor.

Various measurements were conducted at different time periods to account for the variations with time and to test the reproducibility of the methods.

In this study, a Liqui-Cel MiniModule 1 × 5.5 was used as a gas–liquid contactor. The main characteristics of the module are presented in Table 1. The gas flow is fed in the lumen side of the fibers and the liquid flow in the shell side of the module. The membrane acts as a barrier between gas and liquid phases and does not add selectivity for one gas species over the other. The gas fills the pores of the hydrophobic membrane but does not spread in the liquid as long as the pressure of the liquid phase is kept higher than that of the gas phase. Therefore, a gas–liquid interface is created at the pores mouth, where the absorption process takes place.

Table 1 Main characteristics of the Liqui-Cel MiniModule 1 × 5.5

The membrane gas absorption pilot unit whose process flow diagram is shown in Fig. 2 was installed near the flue, where a slip stream of the flue gases was continuously sampled and fed in the lumen side of the hollow fiber membrane module. The slip stream was cooled down from ~90 to ~30 °C and pretreated for particulate matter and water vapor removal before entering the membrane module. A 0.25 M aqueous (diethanolamine) DEA solution was chosen as a typical solvent for CO2 capture processes. The solvent was counter-currently fed in the shell side of the membrane module in a cross flow configuration, using an ISM446 BVP-Z Standard Gear Pump, chosen to provide a pulseless liquid flow. Figures 3 and 4 show two pictures of the equipment installed in Maliouris facilities for the pilot tests.

Fig. 2
figure 2

Process flow diagram of the membrane contactor pilot unit

Fig. 3
figure 3

Picture of the slip stream taken from the flue and the CO2 analyzer used for on-line measurements

Fig. 4
figure 4

Picture of the membrane contactor unit installed in Maliouris facilities for CO2 capture (1 Unit’s control panel, 2 Membrane module, 3 Liquid feed pump, 4 Gas compressor installed in the gas outlet of the module, 5 DEA feed tank)

Results and discussion

The mean concentrations of the main pollutants in the flue gases are shown in Table 2. The results indicated that the flue gas stream is loaded with a number of other pollutants which could have synergistic effects and affect the performance of the process compared to laboratory experiments. Based on the flue gas analysis, the slip stream was cooled down and filtered for humidity and PM removal to protect the membrane module located downstream.

Table 2 Mean concentration of the main pollutants in the flue gases

Figure 5 illustrates the CO2 (left) and NO (right axis) concentration in the flue gas slip stream (inlet of the membrane module) with time. CO2 concentration varies between 0.5 and 3.75 % in a 23-min time period; the same behavior is observed for NO concentration varying between 5 and 60 ppm. This is due to a fluctuant dilution of the flue gases caused by the furnace doors opening when wagons with bricks enter and exit the furnace. Therefore, it is preferable to assess the module’s performance by measuring the CO2 concentration in the inlet and outlet of the module continuously rather than working with mean concentrations.

Fig. 5
figure 5

CO2 and NO concentration in the flue gas slip stream, and correlation with chimney and module inlet temperature variation with time

The same figure depicts the temperature variation in the chimney and the membrane module inlet with time. It is evident that the same pattern with CO2/NO concentrations variations exists, which indicates that temperature and concentration curves are strongly correlated as they both are affected by the different steps of the furnace operation. When chimney’s temperature falls below 90 °C, it is anticipated that bricks’ firing process has already been stalled and tunnel’s cooling is in progress. Below this temperature there is also a decrease of the CO2/NO concentrations, while for higher temperatures these concentrations increase. A slight hysteresis of the temperature response may be attributed to gaseous accumulation within the tunnel, and most importantly due to the thermal inertia of the tunnel walls material to endure the high temperatures imposed by the process. The gaseous components are cooled before entering the membrane module not to exceed 40 °C, so that the module’s inlet temperature remains constant over time.

The % CO2 removal was chosen as a typical performance indicator and the liquid to gas flow ratio as the main controlling variable of the process. In this study, four sets of experimental conditions were used to assess the performance of the membrane contactor process as indicated in Table 3, while the concentration of DEA remains constant at the mild level of 0.25 M. Specifically, four different liquid to gas flow rates were tested (starting from a low value of 0.09 and increasing up to 1.26) to study the effect of the main controlling variable to process performance. These four cases were developed on-site, by gradually increasing the liquid to gas flow rate until an almost complete CO2 capture was attained.

Table 3 Main process variables for the different cases tested for CO2 capture

At this point, it must be noted that studying solvent regeneration after CO2 capture was out of the scopes of this study. DEA regeneration is an energy-intensive process which apparently affects process economics. However, it is a common problem met in any scrubbing process, regardless of how CO2 capture was realized, which must be separately studied.

Figure 6 shows the test results for Case A. Specifically, the molar fraction of CO2 in the inlet and outlet stream of the membrane module, and the respective CO2 recovery attained, with time, are presented. In Case A where a low liquid to gas flow rate was chosen, the CO2 molar fraction at the outlet, as well as the CO2 recovery, varies according to the variation of CO2 at the inlet. A maximum of ~90 % recovery can be attained when the inlet CO2 is low, which drops to ~60 % when the inlet CO2 is high. This indicates that the liquid flow rate is inadequate to handle the feed gas stream and higher liquid to gas flow rate must be used.

Fig. 6
figure 6

CO2 recovery and molar fraction in the inlet/outlet of the module for Case A

Figure 7 shows the test results for Case B. When a higher liquid to gas flow rate was used the molar fraction of CO2 in the outlet as well as the CO2 recovery, after an initial transient period tend to reach a plateau despite the fluctuation of CO2 concentration in the inlet. In this case, a ~90 % CO2 recovery can be attained.

Fig. 7
figure 7

CO2 recovery and molar fraction in the inlet/outlet of the module for Case B

Figure 8 shows the test results for Case C where a higher liquid to gas flow rate was used. In this case, the system has no observable variation regarding the outlet CO2 concentration and CO2 recovery despite the fluctuation of the inlet CO2 concentration. In this case, a ~95 % CO2 recovery can be attained.

Fig. 8
figure 8

CO2 recovery and molar fraction in the inlet/outlet of the module for Case C

Figure 9 shows the test results for Case D where the highest liquid to gas flow rate ratio of the set examined was used, exceeding unity. In this case, the system has the same behavior as in Case C but a ~98 % CO2 recovery can be achieved.

Fig. 9
figure 9

CO2 recovery and molar fraction in the inlet/outlet of the module for Case D

An overall assessment of the test results confirms that the liquid to gas flow rate is the main controlling variable of the process. The membrane-based gas absorption process premises CO2 transport from gas to the liquid phase. This mass transport phenomenon can be described with a resistance in series model. Specifically, three different resistances can be identified; the gas phase resistance, the membrane resistance and the liquid phase resistance, with CO2 concentration gradient to be the driving force in any case. As the liquid to gas flow rate increases all the resistances decrease and the CO2 recovery increases. This is caused both by the improved hydrodynamic conditions as well as by the increased driving force, due to the lower CO2 concentration in the liquid phase [11, 15]. Therefore, we can precisely control the overall process performance, according to the specific process needs, by controlling the liquid to gas flow rate. It is evident that high liquid to gas flow rates could lead to an almost complete CO2 capture, which would not be affected by CO2 concentration variation in the flue gases. However, this would lead to high solvent consumption, which would negatively affect the process economics, rendering it unpractical for industrial application.

At this point, it must be noted that a detailed techno-economic analysis and a feasibility study of the proposed technology are out of the scopes of this study. Nevertheless, it can be noted that a comparison of the proposed technology with the conventional gas absorption towers is in favor of membrane technology when substantial benefits are expected by the much smaller volume and high flexibility of membrane contactors relative to packed columns, since the use of a membrane absorber can lead to a tenfold reduction in equipment size [11, 14]. However, it is often pointed out in the literature that the price of the membranes must be reduced and their reliability must be increased to displace the well-established technologies [16, 17].

Conclusions

A membrane contactor pilot unit was installed and tested for CO2 capture from the flue gases of a Greek brick production industry. The special feature of this process compared to the common combustion ones is that the system is far from steady state and the CO2 concentration in the flue gases strongly varies with time. The CO2 recovery was chosen as a typical performance indicator and the liquid (0.25 M aqueous DEA solution) to gas flow ratio as the main controlling variable of the process. The experimental results indicated that a steady CO2 capture of 90–95 % can be achieved using mild concentration of the amine solution regardless of the CO2 concentration variation in the flue gases, using a liquid to gas flow rate of 0.6–0.95. Lower liquid to gas flow rate ratios have a poor performance presenting high variation (depending on the fluctuation of CO2 concentration in the flue gases), but still higher than 60 %; higher liquid to gas flow rate ratios require high solvent consumption with marginal increase in CO2 capture. An overall assessment of the process demonstrates the high potential and flexibility of the proposed technology to post-combustion CO2 capture in many industrial sectors.