FormalPara Key Summary Points

Why carry out this study?

The 1060-nm diode laser can be used for noninvasive laser lipolysis to remove unwanted fat on medial knees.

The study aims to evaluate the safety and efficacy of a 1060-nm diode laser for medial knee fat reduction.

What was learned from the study?

The results showed a significant reduction in knee circumferences and knee fat thickness measured by ultrasound.

The 1060-nm diode laser is effective and safe for knee circumference and medial knee fat layer thickness reduction.

Introduction

Many women share concerns about the appearance of their knees. Weight gain, sagging skin related to aging or recent weight loss, and decreased muscle tone from inactivity or injury can all affect the appearance of the knee area. These changes are frustrating to women and can affect them emotionally and socially [1]. According to Chamosa, the medial knee zone has the greatest deposits of adipose tissue [1, 2]. Excessive fat on knees can also be genetically predisposed and is resistant to diet and regular exercise [1].

Liposuction and lipectomy are some of the surgical procedures carried out by medical professionals to address unwanted fat in this area [1, 3]. However, these can be traumatic to patients and have slower recovery time, and can have unpredictable results and serious adverse events [1, 3]. According to literature, lipectomy on knee area is prone to persistent edema, hyperpigmentation, prolonged pain, irregularities, and cutaneous necrosis [1].

With the advancement of technology, many noninvasive treatment modalities have been developed to address fat reduction in several areas of the body, such as monopolar and bipolar radiofrequency (RF) [4], cryolipolysis [5,6,7], high-intensity focused ultrasound (HIFU) [8, 9], and lasers [1, 3, 10,11,12,13]. These procedures have quicker postoperative recovery and better patient safety profiles [1, 3,4,5,6,7,8,9,10,11,12,13].

The 1060-nm diode laser had been proven to cause fat reduction in several studies by clinical and histological assessments [10,11,12,13]. Because of its longer wavelength, it produces hyperthermia within the range of 42–47 °C, which can reach the subcutaneous tissue, resulting in adipocyte apoptosis, which subsequently stimulates inflammatory response [10]. The inflammatory response signals the removal of disrupted adipocytes and cellular debris by attracting more macrophages and removing them through phagocytosis. Its safety in patients with skin of color was evident in previous studies [10, 12, 13].

Decorato and colleagues demonstrated the optimal duration of 1060-nm diode laser treatment, which is 20–25 min to cause significant adipocyte injury. When used for longer than 25 min, it can create palpable nodules in the subcutaneous fat [11, 13]. Katz and colleagues demonstrated significant fat reduction in the flanks at 12 weeks post-treatment based on calculations from ultrasound images [10]. Similarly, significant fat layer thickness reduction in the abdomen was documented from the study initiated by Bass et al. [11]. So far, no clinical studies have been carried out on the use of 1060-nm diode laser for knee contouring. The purpose of this study is thus to evaluate the safety and efficacy of a 1060-nm diode laser for medial knee fat reduction.

Methods

A prospective study was carried out, enrolling 19 healthy female subjects aged from 26 to 43 years and presenting with body weight of 45–87 kg. Demographic data, clinical history, and physical examination of medial knees at 3 cm above the medial epicondyle of the femur of each subject were taken by the investigators.

Subjects with the following conditions were excluded from the study: pregnant or lactating women and those with previous history of liposuction or surgical procedures, previous treatment of botulinum injections and laser procedures, or immunosuppressive disorders such as human immunodeficiency virus (HIV) infections and malignancies, those taking immunosuppressant drugs, with previous history of herpes virus infection, underlying psychological conditions, history of hypertrophic scar or keloid formation, history of any skin infections, and skin hypersensitivity or photosensitivity reaction.

The investigators evaluated each subject’s unwanted localized fat on their medial knees. The area to be treated was outlined while the subject was in upright position. The treated area was marked with a template by investigator. Each subject was treated with a single session of 1060-nm diode laser (Sculpsure, Cynosure, Westford, MA) on their medial knees in straight-leg sitting position. One applicator was placed at each medial knee along the contour of treated area. The frame and strap were placed at each side of medial knee to ensure constant distance aligned with the template mark. The power settings used were 1.0–1.4 W/cm2, depending on the subject’s tolerance. The exposure time in all subjects was 25 min for each side of the medial knee [10, 11]. After treatment, subjects were asked to rate their pain using a 10-point scale (0 = none to 10 = worst).

At 1, 3 and 6 months posttreatment, subjects were asked to return for follow-up visits. During these visits, clinical photographs and ultrasound images were taken. Knee circumferences of the subjects in upright position were measured. Fat thickness in the axial and sagittal plane was also measured using ultrasound images. The primary endpoint of this study was to demonstrate a statistically significant reduction in knee circumference and fat layer thickness at 1, 3, and 6 months posttreatment compared with baseline. Knee circumference was measured in upright position, while fat thickness was measured in supine position using ultrasound imaging device (IU 22 xMATRIX US system, Philips Healthcare, Eindhoven, the Netherlands). Additionally, weight measurements in kilograms were also documented at each visit.

The secondary endpoint of the study was subject satisfaction of 75% or greater after treatment completion. All subjects answered the percentage improvement scale survey at each follow-up visit. Any serious side effects such as hypopigmentation, hyperpigmentation, scarring, fat dystrophy, infection, and paradoxical adipose hyperplasia were also assessed.

Descriptive analysis was used for the demographic data. The data were analyzed using paired t-test (normality) and repeated-measure analysis of variance (ANOVA) for parametric distribution. The statistical analysis was performed using IBM SPSS statistical software for Windows, version 24.0 (IBM Corp., Armonk, NY, USA), with p value < 0.05 indicating statistical significance.

This study was approved by the ethics committee of the Siriraj Institutional Review Board (si 369/2018) and Ethical Committee on Research involving human subjects and conformed to the guidelines of the Declaration of Helsinki of 1964 and its later amendments. Written informed consent was obtained from all subjects prior to their enrollment in the study.

Results

All 19 female subjects completed the study. The demographic data are presented in Table 1. The average age and body weight of all subjects was 32.3 ± 5.3 years and 59.8 ± 11.6 kg, respectively. They received a single treatment session of 1060-nm diode laser with average power setting of 1.3 ± 0.1 W/cm2 (range 1.0–1.4 W/cm2) (Table 1). Body weight changes of subjects at post-treatment follow-ups did not show statistically significant difference (p = 1.000) (Table 2).

Table 1 Demographic data of patients enrolled in the study
Table 2 Assessment of body weight

The average knee circumference at baseline was 44.0 ± 4.5 cm. Data showed significant reduction of average knee circumference at 1 month (42.7 ± 4.2 cm), 3 months (41.9 ± 4.8 cm), and 6 months (41.3 ± 4.4 cm) compared with baseline (p < 0.0001) (Table 3). There was continuous decrease of circumference at each follow-up period.

Table 3 Assessment of knee circumference (cm)

The average fat layer thickness at baseline in axial and sagittal plane was 2.4 ± 0.8 cm and 2.5 ± 0.8 cm, respectively (Table 4). Fat thickness of 2.0 ± 1.1 cm in axial plane and fat thickness of 2.0 ± 0.9 cm in sagittal plane both evaluated by ultrasound showed a significant reduction as early as 1 month after treatment compared with baseline (p = 0.036, p = 0.001, respectively) (Table 4). Further decrease of fat thickness at 6 months after treatment in axial plane (1.5 ± 0.8 cm) and sagittal plane (1.6 ± 0.9 cm) was noted. The results were statistically significant (p < 0.001) (Table 4).

Table 4 Assessment of fat thickness measured by ultrasound (cm)

Based on the dynamic subgroup analysis, non-weight-gainers responded better to treatment (Tables 3, 4). The average knee circumference of non-weight-gainers was reduced significantly at 1, 3, and 6 months after a single treatment (p < 0.001, p = 0.005, and p < 0.001, respectively). The fat thickness of the non-weight-gainer group showed significant reduction at 6 months after treatment in axial plane (p < 0.001) and at 1 and 6 months in sagittal plane (p = 0.026 and p < 0.001, respectively).

On the other hand, the average knee circumference of weight-gainers showed significant reduction at 3 and 6 months only compared with baseline (p = 0.002 and p = 0.028, respectively) (Table 3). The fat thickness of the weight-gainer group showed significant reduction at 6 months after treatment, in both axial and sagittal plane (p = 0.006 and p = 0.003, respectively) (Table 4).

The results showed that 17.7% of subjects at 3 months and 47.1% of subjects at 6 months after treatment rated greater than 75% improvement and were satisfied with treatment outcome (Fig. 1). Clinical photographs and ultrasound images of representative subjects are shown in Figs. 2 and 3, each showing improvement in contour at 1, 3, and 6 months after the treatment.

Fig. 1
figure 1

Improvement scale evaluated by patients

Fig. 2
figure 2

Representative images of right medial knee of patient (case 1) after single session of 1060-nm diode laser

Fig. 3
figure 3

Representative ultrasound images of patient after single session of 1060-diode laser; S skin, SF subcutaneous fat, M muscle

The average pain score recorded was 6.1 ± 1.0 (Table 1). All subjects reported mild erythema and mild tenderness immediately after treatment. The side effects were transient. No serious side effects including hypopigmentation, hyperpigmentation, scarring, fat dystrophy, infection, and paradoxical adipose hyperplasia were found throughout the study.

Discussion

The advent of new technology such as noninvasive body-contouring devices has changed the business of surgical treatments and provided new options for addressing fat reduction. Lipolysis devices such as radiofrequency [4], cryolipolysis [5,6,7], ultrasound [8, 9], and lasers [1, 3, 10,11,12,13] are now being used worldwide as alternative procedures to remove fat in unwanted areas with a better safety profile compared with liposuction and other surgical procedures [1,2,3,4,5,6,7,8,9,10,11,12,13]. Each device has its own mechanism and efficacy profile [4,5,6,7,8,9,10,11,12].

A previous cryolipolysis study of 20 females with localized subcutaneous fat on arms or inner thighs showed significant circumference reduction at 3- and 6-month follow-up visits [5]. The efficacy was comparable to the present study, which also demonstrated reduction at 3 and 6 months post-treatment. Cryolipolysis works by inducing adipocyte apoptosis and inflammatory response using cold temperatures without damaging surrounding areas [5,6,7], while laser lipolysis generates controlled hyperthermia using a specific wavelength and optimal power in the subcutaneous layer and causes photothermal reaction that destroys adipocytes and stimulates inflammatory response [10, 13]. In the study by Decorato et al., hyperthermic laser lipolysis was comparable to cryolipolysis in average fat reduction at 3 and 6 months after treatment [13].

Previously conducted studies of 1060-nm diode laser showed significant reduction of localized subcutaneous fat on flanks [10] and abdomen [11]. The previous pilot study on the flanks demonstrated significant average fat reduction based on ultrasound images [10]. At 12 weeks after treatment, 96% (41/43) of subjects rated that they were satisfied with the treatment outcome [10]. Using the same device, Bass et al. showed a mean reduction in fat layer thickness of the abdomen from baseline at both 6 and 12 weeks after treatment [11]. At 12 weeks, 91% (31/34) of subjects were satisfied with the treatment [11].

In the present study, the results showed significant reduction of average knee circumference at 1 month (42.7 ± 4.2 cm), 3 months (41.9 ± 4.8 cm), 6 months (41.3 ± 4.4 cm) compared with baseline (p < 0.0001) (Table 3). Also, significant reduction in fat thickness of 2.0 ± 1.1 cm in axial plane and fat thickness of 2.0 ± 0.9 cm in sagittal plane at 1 month after treatment (p = 0.036, p = 0.001, respectively) and fat thickness of 1.5 ± 0.8 cm in axial plane and 1.6 ± 0.9 cm in sagittal plane at 6 months after treatment (p < 0.001) (Table 4) were also calculated based on ultrasound images. In our study, 17.7% of subjects at 3-month and 47.7% of subjects at 6-month follow-up visits rated > 75% improvement. The results of this study highlight that the 1060-nm diode laser is effective for subcutaneous fat reduction on medial knees. Considering that the laser device is kept in contact with the treated area using accessories (strap and frame) and the tapering of the temperature, the heat from the diode laser is localized to adipose tissue in the treatment area [10]. The patient satisfaction may be due to the medial knee fat reduction with smooth contour and lower rates of complications.

Similar to previously conducted studies, no severe adverse events were reported in our study [10, 11]. In a previous study using 924/975-nm diode laser, none of the patients presented persistent edema and pain. Of the 30 patients, 29 recommended the treatment [1]. In the study by Katz et al., the majority (83%) of reported events were mild and temporary. The subsequent events reported in the study by Katz were edema (resolved within 4–6 days), pain and bruising (resolved within 9–11 days), and subcutaneous nodules (resolved within 32–78 days) [10]. In addition, Bass and colleagues documented post-treatment tenderness as the most common adverse event [11]. Seventy-four percent of adverse events were reported as mild, 26% as moderate, and none as severe [11].

In our study, the average pain score recorded was 6.1 ± 1.0 (Table 1). All subjects reported mild tenderness and erythema immediately after treatment. No hypopigmentation, hyperpigmentation, scarring, fat dystrophy, infection, or paradoxical adipose hyperplasia were documented. The authors suggest that the best candidates and indications for noninvasive body contouring are patients who expect a mild to moderate result. Therefore, good candidates must be selected with realistic expectations.

In addition, our study showed that non-weight-gainers responded better to treatment. The average knee circumference of non-weight-gainers was reduced significantly at 1, 3, and 6 months after the single treatment (p < 0.001, p = 0.005, and p < 0.001, respectively) (Table 3). The average fat thickness of the non-weight-gainer group showed significant reduction at 6 months after treatment in both axial and sagittal plane (p < 0.001 and p < 0.001, respectively) (Table 4). Considering the current findings, the authors believe that diet control and regular exercise must be integrated with the subject’s lifestyle to maintain the treatment results and patient satisfaction.

To the best of our knowledge, this is the first study reporting the clinical efficacy and safety of a 1060-nm diode laser in the treatment of localized fat on medial knees. The limitations of the study include the small sample size, the lack of a comparative group, and short follow-up period. It would be prudent to conduct related studies with more subjects, additional treatment sessions, and longer follow-up to further examine the safety and efficacy of the 1060-nm diode laser on medial knees.

Conclusions

The 1060-nm diode laser demonstrated significant efficacy for knee circumference and medial knee fat layer thickness reduction. The future of the 1060-nm diode laser looks bright given its favorable safety profile.