Skip to main content
Log in

Performance Evaluation of a Portable Neutron Generator for Prompt Gamma-Ray Applications

  • Research Article - Physics
  • Published:
Arabian Journal for Science and Engineering Aims and scope Submit manuscript

Abstract

Performance of a D–D reaction-based portable pulsed neutron generator model MP320 was evaluated for prompt gamma applications. The operating beam energy and beam current of the MP320 generator were determined through prompt gamma-ray yield measurements from iron. The chlorine prompt gamma-ray yield was also measured from saline water samples containing 1.0–4.0 wt% chlorine to test the neutron flux efficacy of the MP320 generator for prompt gamma applications. The results of the study showed satisfactory performance of the MP320 generator for prompt gamma neutron activation application studies.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Atanackovic, J.; Grinyer, C.J.; Byun, D.R.: The comparison of two MCNP models used for prompt gamma in vivo detection of cadmium and mercury.Nuclear Instrum. Methods Phys. Res. Sect. B Beam Interact. Mater. Atoms B263, 169–174 (2007)

    Google Scholar 

  2. Chichester D.L., Simpson J.D., Lemchak M.: Advanced compact accelerator neutron generator technology for active neutron interrogation field work. J. Radioanal. Nuclear Chemi. 271, 629–637 (2007)

    Article  Google Scholar 

  3. Choi H.D.; Firestone, R.B.; Lindstrom, R.M.; Molnar, G.L.; Mughabghab, S.F.; Paviotti-Corcuera, R.; Revay, Z.S.; Trkov, A.; Zhou, C.M.: Database of prompt gamma-rays from slow neutron capture for elemental analysis. Compiled by International Atomic Energy Agency, Vienna (2006)

  4. Fantidis J.G., Nicolaou G., Tsagas N.F.: A Monte Carlo simulation of neutron activation analysis of bulk objects. Radiat Meas 44, 273–277 (2009)

    Article  Google Scholar 

  5. Howell S.L., Sigg R.A., Moore F.S., DeVol T.A.: Calibration and validation of a Monte Carlo model for PGNAA of chlorine in soil. J. Radioanal. Nuclear Chem. 244, 173–178 (2000)

    Article  Google Scholar 

  6. Idiri, Z.; Mazrou, H.; Amokrane, A.; Bedek, S.: Characterization of an Am-Be PGNAA set-up developed for in situ liquid analysis: application to domestic wastewater and industrial liquid effluents analysis. Nuclear Instrum. Methods Phys. Res. Sect. B Beam Interact. Mater. Atoms B268, 213–218 (2010)

  7. Khelifi R., Amokrane A., Bode P.: Detection limits of pollutants in water for PGNAA using Am-Be source. Nuclear Instrum. Methods Phys. Res. Sect. B Beam Interact. Mater. Atoms 262, 329–332 (2007)

    Article  Google Scholar 

  8. Livingston R.A., Al-Sheikhly M., Ali M.B.: Numerical simulation of the PGNA signal from chlorine diffusion gradients in concrete. Appl. Radiat. Isot. 68, 679–682 (2010)

    Article  Google Scholar 

  9. Naqvi A.A., Maslehuddin M., Garwan M.A., Nagadi M.M., Al-Amoudi O.S.B., Raashid M., Raashid M.: Effect of silica fume addition on the PGNAA measurement of chlorine in concrete. Appl. Radiat. Isot. 68, 412–417 (2010)

    Article  Google Scholar 

  10. Naqvi, A.A.; Maslehuddin, M.; Garwan, M.A.; Nagadi, M.M.; Al-Amoudi O.S.B.; Khateeb ur-Rehman; Raashid, M.: Estimation of minimum detectable concentration of chlorine in the blast furnace slag cement concrete. Nuclear Instrum. Methods Phys. Res. B 269, 1–6 (2011)

  11. Paul R.L., Lindstrom R.M.: Prompt gamma-ray activation analysis: fundamentals and applications. J. Radioanal. Nuclear Chem. 243, 181–189 (2000)

    Article  Google Scholar 

  12. Vincke H., Gschwendtner , E. , Fabjan C.W., Otto T.: Response of a BGO detector to photon and neutron sources: simulations and measurements. Nuclear Instrum. Methods Phys. Res. A 484, 102–110 (2002)

    Article  Google Scholar 

  13. Briesmeister, J.F. (ed.): MCNP4B2 –A General Monte Carlo N-Particles Transport Code. Los Alamos National Laboratory Report LA-12625-M, Version 4A (1997)

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. A. Naqvi.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Naqvi, A.A., Kalakada, Z., Al-Anezi, M.S. et al. Performance Evaluation of a Portable Neutron Generator for Prompt Gamma-Ray Applications. Arab J Sci Eng 39, 531–539 (2014). https://doi.org/10.1007/s13369-013-0880-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s13369-013-0880-y

Keywords

Navigation